Page: 40 - Installation Manual - NC-200 PB
PAR21
Indicates the active level of the first 8 inputs.
By default, they are set to "1" meaning that they are activated with 24V.
Digit
Pin
8
33
BCD 2
7
14
BCD
6
32
Retract X axis / Feed in forced mode.
5
13
Go to next block
4
31
Y axis negative travel limit
3
12
X axis negative travel limit
2
30
Y axis positive travel limit
1
11
X axis positive travel limit
PAR22
Indicates the active level of the next 7 inputs.
By default, they are set to "1" meaning that they are activated with 24V.
Digit
Pin
8
Not being used at this time. It must be set to "0".
7
23
Emergency
6
8
"Return" foot switch.
5
36
External key 3 (A). EXECUTION mode selector
4
35
External key 2 (A). "BEND" foot switch.
3
16
External key 1 (A). EXECUTION mode selector
2
34
Disable the "Y" axis (Teach-in)
1
15
Hands-on palm switches / pressure level.
PAR23
Indicates the active level of the first 8 outputs.
By default, they are set to "1" meaning that when activated, they
provide 24V.
Digit
Pin
8
10
"H" output
7
27
Manual mode active
6
26
"Y" axis moving direction
5
7
"X" axis moving direction
4
25
"Y" axis fast movement
3
6
"X" axis fast movement
2
24
"Y" axis enable
1
5
"X" axis enable
PAR24
Indicates the active level of the next 3 outputs.
By default, they are set to "1".
Digit
Pin
8-4
Not being used at this time. They must be set to "0".
3
29
Axes in position (A). RAM down.
2
9
Buzzer. RAPID approach (B)
1
28
Retract RAM.