2.3.2 OUTPUT DESCRIPTION
If any of the outputs is going to be connected to some highly inductive device,
a "1N4000" type diode must be installed in antiparallel. It is not required on
auxiliary relays of less than 20 mA.
The drives are enabled with auxiliary relays (section 5.2).
P I N
FUNCTION
5, 6, 7,
24, 25, 26
Axis enable
F A S T / S L O W
DIRECTION PAR46
27
MANUAL mode
10
H output
Models A, A1, B
Ram retraction.
Section 2.3.4
Model A
Axes in position
Model A1
Approach and
bending
Model B
Model B
Model A, A1, C
DESCRIPTION
Analog voltage
outputs. PAR 64,
P A R 6 5
18, 37
It activates the auxiliary output to raise the X axis backstop. R
axis function, ON /OFF conditioned by the "H" editing attribute.
Enabling drives or frequency inverters for open loop control.
To control drives in closed loop drives.
When installing a pressure transducer or potentiometric scale,
connect it to pin 18 and change the position of the internal
jumper.
MANUAL mode selection confirmation.
SLOW approach.
Section 2.3.4
A - Retraction control by trigger time of the thermostat
conditioned by the "D" attribute.
Single output.
The FAST/SLOW change is handled with external resources
from the electrical cabinet that manages the FAST buttons and
the change switch.
I15 when exceeding the bending pressure
29
9
I32 (A, A1) or Y = e (B, C) at the beginning of the bend if
attribute B
A1, B - Forced retraction up to the top dead point. Bending time
conditioned by the "D" attribute.
28
At all models, it is reset with :
It resets in the programmable change position that forces the
slow motion output O29.
Fast movement
handling. Ram
approach.
Buzzer to warn the operator about "permission to bend"
Signal to the electrical cabinet to enable the FAST approach
buttons or SLOW bend footswitch.