MCSi-64/84
Digital Brushless AC servo drive system - Ref.0707
Function:
The OV10 variable contains the value of the output status of
the various functions that may be selected with OP14.
Valid values:
0 and 1.
Default value:
0.
Q group. Communication
Function:
Determines the communications parameters of the UART
(Universal Asynchronous Receiver/Transmitter) of the 485
serial line of connector X1. For the service line USB-COM,
it is always configured as (9600, no parity, 8 data bits, 1 stop
bit).
Default value:
1540 (9600, no parity, 8 data bits, 1 stop bit).
To edit this parameter, the programming module has a
submenu like the one in the figure on the next page.
OV10
USER, RO
DigitalOutputs
QP16
USER, RW
SerialSettings
Bit
Function
15, ..., 12
Reserved
11, 10
Stop bits
1
Stop bits
2
Stop bits
9, ..., 6
Data bits
7
Data bits
8
Data bits
5, 4
Parity bits
0
No parity
1
Even parity
2
Odd parity
3, ..., 0
Communication speed (baudrate)
0
2400 Bd
4
9600 Bd
1
3600 Bd
5
19200 Bd
2
4800 Bd
6
38400 Bd
3
7200 Bd