MCSi-54/84
Digital Brushless AC servo drive system - Ref.0707
Function:
Reset of the DV17 variable HistoricOfErrors (array). This
command sets it to 0.
E group. Encoder simulator
Function:
Number of pulses generated by the encoder simulator per
rotor revolution.
Valid values:
1, ..., Number of pulses of the selected feedback.
Default value:
Number of pulses of the selected feedback device.
Function:
Selection of the turning direction of the simulated encoder.
Valid values:
0/1, clockwise (by default) / counterclockwise.
G group. General
Function:
After deactivating the Speed_Enable and after the GP3 time
has elapsed, if the motor has not stopped, it cancels the
torque automatically and issues error E.004. If the motor
stops within the GP3 time, it also cancels the torque but does
not issue an error. To make this time infinite (never generating
error E.004), set this parameter to "0".
Valid values:
1, ..., 9999 ms, 0 (infinite).
Default value:
500 ms.
Function:
This parameter represents the version of the parameter table
that has been loaded at the drive.
DC2
USER, RW
ResetHistoricOfErrors
EP1
BASIC, RW
EncoderSimulatorPulsesPerTurn
EP3
BASIC, RW
EncoderSimulatorDirection
GP3
BASIC, RW
StoppingTimeout
GP5
BASIC, RO
ParameterVersion