15
CAUSE
PROBLEM
SOLUTION
• It is not plugged in.
• There is no electrical current
to the plug because the fuse
has blown or the automatic
power limiter has activated.
• The connection controls are
not on.
• Plug in.
• Change the fuse or reset the
automatic power limiter.
• Switch the controls on.
• The refrigerator is
incorrectly levelled.
• Level it, with the leveller
bases.
• Temperature selection is set
too hot.
• The door is not properly
closed or is opened very
frequently.
• The space between the
skirting board and floor or
the top of the refrigerator has
been covered.
• The refrigerator is exposed
to direct sunlight or a heat
source.
• A large amount of food has
been introduced.
• In No-Frost refrigerators,
there is something
obstructing the ventilation
grilles
• Set temperature selection to
maximum cold.
• Ensure that the door does not
remain open too long.
• Keep these areas free as
described in the
"Installation" section in this
manual.
• Relocate the refrigerator or
protect it from these heat
sources.
• Consult the section on
"operation and use of the
refrigerator".
• Remove any obstacles
blocking the air outlet of the
ventilation grilles.
• The doors are not properly
closed.
• The doors are opened often.
• The food was introduced
recently.
• Temperature selection in
cold position.
• Close the door properly.
• Avoid opening the door
frequently.
• Wait for the appliance to
return to normal.
• Set the temperature switch to
less cold.
The refrigerator does not
operate
The refrigerator vibrates.
The refrigerator or freezer is
not very cold
The motor runs permanently.
9. TROUBLESHOOTING
FQ8G220A1 8/3/05 08:55 Página 68