Selection criteria
5.
Ref.1912
· 209 ·
DDS
HARDWARE
The power required in this case
P
F
is calculated as follows:
Power needed to accelerate and decelerate an asynchronous
spindle motor
There are three methods to control the acceleration and deceleration
process of the machine spindle:
Acceleration limited by time.
Different acceleration ramps depending on the speed reached.
F. H5/7
Frictional load. Required power.
µ
Friction coefficiente
Mechanical efficiency
m
L
Table mass in kg
V
Linear speed in m/min
F. H5/8
Acceleration limited by time.
T. H5/2
Acceleration limited by time.
Method
Acceleration limited by time.
Control
Speed increases linearly in time until the command speed is
reached.
Comment
The acceleration torque is constant.
F. H5/9
Different accelerations depending on speed.
T. H5/3
Different accelerations depending on speed.
Method
Different accelerations depending on speed
Control
Linear acceleration avoiding abrupt variations in transmitted
torque.
Comment
Emulation of the square sine function for speed by using ramps.
Load
Motor
Speed
P
F
·m
L
·V
6120·
=
(kW)
adjust
time
0
Ta
speed
adjust
time
0
Ta
speed
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......