Probe connection.
The digital inputs let you handle the signal of the two 24 V DC probes . Use machine
parameters to define which digital input is associated with each probe and their type of pulse.
Probe whose output has a normally open contact. Connection to +24 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
Probe whose output has a normally closed contact. Connection to +24 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
Interface with an open-collector output. Connection to +24 V.
The connection acts upon the down flank (negative pulse) of the probe signal.
PROBE
I1
+ 24 V
REMOTE
GROUP
I2
I..
GND
I..
I..
GND
50K
PROBE
I1
+ 24 V
REMOTE
GROUP
I2
I..
GND
I..
I..
GND
PROBE
12K
+ 24 V
I1
REMOTE
GROUP
I2
I..
GND
I..
I..
GND