·30·
Remote modules
CNC 8060
CNC 8065
3.
(R
EF
: 1402)
RIO70
REMOTE MODULES. (C
ANFAGOR PROTOCOL).
3.3
Power Supply.
The power supply must be present in all the configurations (1 per group), it must be powered
at 24 Vdc and connected to the CAN bus of the system.
CAN bus. ·Line Term· selector.
Line terminating resistor.
CAN bus. Connector ·X2·.
CAN bus connection.
CAN bus. ·X3· connector.
CAN bus connection.
GND
CAN L
SHIELD
SHIELD
CAN H
X3
GND
CAN L
SHIELD
SHIELD
CAN H
X2
POWER SUPPLY
4
0
1
F
E
D
C
B
A
9
8
7
6
5
3
2
ADD MSB
LINE TERM
1
0
12
ADDRESS
RESET
POWER
SYSTEM READY
+5 ERROR
+5 OVER CURRENT
OVER VOLTAGE
+5V
X1
GND IN
CHASIS
GND IN
+24V IN
SYSTEM
READY
CAN bus. ·ADD MSB· selector
Address (node) of the element within the CAN
bus.
CAN bus. ·ADDRESS· selector.
Address (node) of the element within the CAN
bus.
·RESET· button.
This button may be used to reset the module.
Leds.
Status indicator LED's.
·OVER VOLTAGE· button
This button may be used to reset the module
after an over-current.
Connector ·X1·.
Power and emergency relay.