BCSD-74/116
Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
4.7. Absolute Encoders
4.7.1. Selecting an Absolute Encoder
An absolute encoder can also be used as an incremental encoder.
Absolute Encoder Type
Resolution Output Range of Multiturn Data
Action when limit is exceeded
BCSD Series
17-bit/
single turn
-32768 ~ +32767
- When the upper limit (+32767) is
exceeded in the forward
direction, the multiturn data is
-32768.
- When the lower limit (-32768) is
exceeded in the reverse
direction, the multiturn data is
+32767.
Parameter
Meaning
Pn002
b.
0
Use the absolute encoder as an absolute encoder. (Factory setting)
b.
1
Use the absolute encoder as an incremental encoder.
- The back-up battery are not required when using the absolute encoder as an incremental encoder.
- After changing these parameters, turn OFF the main circuit and control power supplies and then turn them ON
again to enable the new settings.
Содержание BCSD-08AMA-01
Страница 1: ...SYSTEM BCSD User manual Ref 1809...
Страница 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Страница 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Страница 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Страница 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Страница 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Страница 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Страница 117: ......