Technical Data
Page
12
/
20
8
Technical Data
Electrical connection
Power supply
Output signal
“Empty” signal
Error message
2
-
wire terminal
8 … 30 V DC
4 …
20 mA
3.8 mA or 20.5 mA
21.5 mA or 3.6 mA
Process Connection
Screw
-
in unit (standard R 3/4)
Flange on request
For material, see probe tube
Sensor head
Height above screw
-
in unit/flange 160 mm
Diameter 50 mm
Index of protection IP
68
Material: stainless steel
Cable diameter 5 … 10 mm
Temperature
–40 … +85 °C
Probe tube
Length 200 … 6,000 mm
Diameter of single rod 6 mm (Standard)
Standard material: 1.4571 (316Ti)
Optional material: tantalum, titanium, Hastelloy,
or 1.4404 (316L)
Measuring range freely adjustable (> 10 mm)
Sealing
PEEK (alternatively PTFE)
Measuring accuracy
Digital component
Linearity better than ±1 mm or ±1 %
Resolution better than 0.1 %
Analogue component
Temperature drift better than ±0.01 %/K
Resolution better than 0.5 μA
Process temperature
-
40 … +125 °C
Process pressure
100 bar at 20 °C, 25 bar at 125 °C
Process conductivity
> 1 μS/cm
Содержание CONDURIX DU