Keep to the following to achieve a perfectly working system.
HINDI 880, strong, functional and easy to install, is designed to be fitted to swinging gates by means of two plates, one is to be fixed
to the gate and the other one to the gate post, pillar or brick pier. Check parts as in picture No. 2.
First unscrew the two nuts in the front end cap and remove the anodized, aluminium cover by pulling it horizontally and lay bare the
cylinder, shaft and ball bearing joint for fitting and setting operations. Reinforcement plates are to be provided as shown in the pictures.
Fixing to the gate post is by screwing, welding or setting with concret depending on the type of posts involved. Reinforcement plates
fitted with anchor ended wedges are recommended for better grip in case of brick piers. Distances are strictly as shown in picture 3.
Provide a temporary fixing for the front fixing plate to the gate and swing the operator on to it. The shaft must be fully out, and the ball
bearing joint fully screwed in, the gates in close position. Check alignment of the operators by means of a level. Picture 3.
PISTON SHAFT
BALL BEARING JOINT
- NUT
- THREAD
130
130
50
80
PIC. 2
ELECTRICAL WIRING DIAGRAM OF THE ELECTRONIC
PROGRAMMER
Once the connections have been made, do the first switching
test through the control panel. Set the motor run timer so that
the motor is allowed to run 4 - 5 seconds more than the gates.
Set the other timers to meet the site requirements. Set DIP switch
B No. 3 to
automatic
(ON): on pulsing to 4 - 8 the gates must be
operated as pre-set, ie. opening and only after the dwell time,
closing. Adjust the times through the respective timers. (See No.
07, 08 and 09 drwg. No. 1643). With DIP switch “B” No. 3 to
semiautomatic
(OFF) one pulse opens the gates, a second pulse
to 5 - 8 is needed to close the gates. Any one pulse to 7 - 8 will
open, close or reverse the gates independently from the operation
being performed. It is recommended to carefully read the
instructions in the control box to have all the functions performed
correctly.
The 6 LEDS on the P.C. board indicate the following:
led No. 1 It switches on when voltage is supplied.
led No. 2 Photocells. Normally on. It switches off when the
photocells are obstructed.
led No. 3 Open - It switches on when the respective switch is
activated.
led No. 4 Close - It switches on when the respective switch is
activated.
led No. 5 Stop - Normally on. It switches off when the respective
switch is activated.
led No. 6 Radio - It switches on whenever a pulse is given,
either from remote control, keyswitch or push buttons.
PIC. 3
PIC. 19
CONNECTION DIAGRAM FOR SWING GATES ELPRO 13 exp
INSTRUCTIONS FOR THE INSTALLATION OF HINDI 880, AN ELECTRO-HYDRAULIC
OPERATOR, TWO-WAY LOCKING IN OPEN AND CLOSE GATE POSITION.
1 2 3 4 5
6 7 8 9 10 11 12 13 14 15
16 17 18
7 8
3 4
M1
M2
19 20 21 22 23 24 25
12,5
μ
F
12,5
μ
F
1
2
3
4
5
6
7
8
9
–
ON
OFF
1 2 3 4 5 6 7 8
ON
DIP-SWITCH
TIMER SWITCHES
PIC. 18
Drwg. No.
1643
P.C. BOARD
LED No. 1 - It switches on when voltage is supplied
OPEN
STOP
CLOSE
N.O.
N.C.
N.O.
3
4
5
6
26 27 28 3
CONNECTION TO THE “PULIN 3”
PUSH BUTTONS WITH STATUS INDICATION LEDS
0
REAR FIXING PLATE
REAR FIXING BOLT
SPECIFICATIONS
TOP LID
RELEASE KEY 1625
VALVE ARRANGEMENT
LOCK COVER
KEY
VALVE “OPEN”
VALVE “CLOSE”
LOCKING/RELEASE VALVE
PLUG
4 WIRE CABLE
REAR FIXING BRACKET
SELF-LOCKING NUT
REAR END BLOCK
OIL RESERVOIR ANODIZED
VALVE PROTECTION ENCLOSURE
CYLINDER/SHAFT
RED LIVE
BLACK NEUTRAL
RED LIVE
YELLOW/GREEN EARTH
CIRCLIP
BALL BEARING JOINT
FRONT FIXING PLATE
WITH PIN
COVER ANODIZED
ALUMINIUM
PLUG
NUTS
BOX WRENCH
SCREWDRIVER
NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES ONLY
THROUGH FADINI ACCESSORIES. NO WARRANTY IS
ACKNOWLEDGED BY THE MANUFACTURER IN CASE THAT
OTHER ACCESSORIES ARE USED OR NON CONFORMING
APPLICATIONS ARE MADE WITHOUT THE MANUFACTURER’S
APPROVAL.
NOTE WELL. For special applications, ie. to switch on lights
- CCTV etc..., SOLID STATE RELAYS are recommended to be
used only. Standard relays would affect the micro-processor.
ALL OPERATIONS
OPEN, CLOSE
& REVERSE
RADIO CONTACT
PULSE TWICE CONSECUTIVELY
TO OPEN BOTH GATE LEAFS
PEDESTRIAN MODE
ONE PULSE OPENS
ONE GATE LEAF ONLY
Should more pairs of photocells be
required than the recommended
quantity
, fit an auxiliary transformer
outside the control box.
= PHOTOCELLS 2nd P
A
IR=
INSIDE PHOTOCELLS N.C. CONT
ACT
.
IF OBSTRUCTED, THEY PREVENT THE
GA
TES FROM OPENING, REVERSE GA
TE
DIRECTION DURING CLOSE CYCLE.
TERMINALS FOR THE
CONNECTION OF THE
PUSH BUTTONS PULIN 3
RADIO CONTROL
PLUG-IN CARD SUPPORT
24 V OUTPUT
1
°
CHANNEL
DWELL TIME
MOTOR RUN TIME
OPEN & CLOSE
ON TO “0” THE DELAY
IS OUT OF SERVICE
MICRO PROCESSOR
LEAF DELAY
TIMER
CLOSE
CAPACITORS
1 AMP.
FUSE: 24 V OUTPUT
TERMINALS 12-13
630 mA
FUSE
630 mA FUSE
FLASHING LAMP
5 AMP. FUSE
ELECTRIC MOTORS
SINGLE-PHASE
FLASHING LAMP
230 V - 25 W max.
230 V SINGLE-PH.
SUPPL
Y VOL
TAGE
COMMON
COMMON
N.C. CONT
ACT
PHOTO CELLS
STOP SWITCH N.C. CONT
ACT
24 V OUTPUT
A.C.
MAX. PERMITTED LOAD:
2 P
AIRS PHOTOCELLS
1 RADIO RECEIVER
OPEN SWITCH N.O. CONT
ACT
COMMON
VOL
TAGE OUTPUT
ELECTRIC LOCK SUPPL
Y
SAFETY CONT
ACT N.C.
CLOSE SWITCH N.O. CONT
ACT
RADIO CONT
ACT N.O.
COMMON
24 V INDICA
TOR 3 W MAX.
+
+
+
26
27
28
CLOSE N.O. CONTACT
OPEN N.O. CONTACT
COMMON
STOP N.C. CONTACT
RADIO CONTACT
TERMINAL BOARD
ELECTRICAL CONNECTIONS
KEYSWITCH PRIT 19
12
3
4
STOP
OPEN
CLOSE
COMMON
TERMINAL BOARD
PRIT 19
1 2 3 4 5 6 7 8 9 10 11 12 13