background image

9

4

Keep to the following to achieve a perfectly working system.
HINDI 880, strong, functional and easy to install, is designed to be fitted to swinging gates by means of two plates, one is to be fixed
to the gate and the other one to the gate post, pillar or brick pier. Check parts as in picture No. 2.

First unscrew the two nuts in the front end cap and remove the anodized, aluminium cover by pulling it horizontally and lay bare the
cylinder, shaft and ball bearing joint for fitting and setting operations. Reinforcement plates are to be provided as shown in the pictures.
Fixing to the gate post is by screwing, welding or setting with concret depending on the type of posts involved. Reinforcement plates
fitted with anchor ended wedges are recommended for better grip in case of brick piers. Distances are strictly as shown in picture 3.

Provide a temporary fixing for the front fixing plate to the gate and swing the operator on to it. The shaft must be fully out, and the ball
bearing joint fully screwed in, the gates in close position. Check alignment of the operators by means of a level. Picture 3.

PISTON SHAFT

BALL BEARING JOINT

- NUT
- THREAD

130

130

50

80

PIC. 2

ELECTRICAL WIRING DIAGRAM OF THE ELECTRONIC
PROGRAMMER

Once the connections have been made, do the first switching
test through the control panel. Set the motor run timer so that
the motor is allowed to run 4 - 5 seconds more than the gates.
Set the other timers to meet the site requirements. Set DIP switch
B No. 3 to 

automatic

 (ON): on pulsing to 4 - 8 the gates must be

operated as pre-set, ie. opening and only after the dwell time,
closing. Adjust the times through the respective timers. (See No.
07, 08 and 09 drwg. No. 1643). With DIP switch “B” No. 3 to

semiautomatic

 (OFF) one pulse opens the gates, a second pulse

to 5 - 8 is needed to close the gates. Any one pulse to 7 - 8 will
open, close or reverse the gates independently from the operation
being performed. It is recommended to carefully read the
instructions in the control box to have all the functions performed
correctly.

The 6 LEDS on the P.C. board indicate the following:

led No. 1 It switches on when voltage is supplied.
led No. 2  Photocells. Normally on. It switches off when the

photocells are obstructed.

led No. 3  Open - It switches on when the respective switch is

activated.

led No. 4  Close - It switches on when the respective switch is

activated.

led No. 5  Stop - Normally on. It switches off when the respective

switch is activated.

led No. 6 Radio - It switches on whenever a pulse is given,

either from remote control, keyswitch or push buttons.

PIC. 3

PIC. 19

CONNECTION DIAGRAM FOR SWING GATES ELPRO 13 exp

INSTRUCTIONS FOR THE INSTALLATION OF HINDI 880, AN ELECTRO-HYDRAULIC
OPERATOR, TWO-WAY LOCKING IN OPEN AND CLOSE GATE POSITION.

1 2 3 4 5

6 7 8 9 10 11 12 13 14 15

16 17 18

7    8

3    4

M1

M2

19 20 21 22 23 24 25

12,5

μ

F

12,5

μ

F

1

2

3

4

5

6

7

8

9

ON

OFF

1   2   3   4   5   6   7   8

ON

DIP-SWITCH

TIMER SWITCHES

PIC. 18

Drwg. No. 

1643

 P.C. BOARD

LED No. 1 - It switches on when voltage is supplied

OPEN

STOP

CLOSE

N.O.

N.C.

N.O.

3

4

5

6

26 27 28 3

CONNECTION TO THE “PULIN 3”
PUSH BUTTONS WITH STATUS INDICATION LEDS

0

REAR FIXING PLATE

REAR FIXING BOLT

SPECIFICATIONS

TOP LID

RELEASE KEY 1625

VALVE ARRANGEMENT

LOCK COVER

KEY

VALVE “OPEN”
VALVE “CLOSE”
LOCKING/RELEASE VALVE
PLUG

4 WIRE CABLE

REAR FIXING BRACKET

SELF-LOCKING NUT

REAR END BLOCK

OIL RESERVOIR ANODIZED

VALVE PROTECTION ENCLOSURE

CYLINDER/SHAFT

RED LIVE
BLACK NEUTRAL
RED LIVE
YELLOW/GREEN EARTH

CIRCLIP

BALL BEARING JOINT

FRONT FIXING PLATE
WITH PIN

COVER ANODIZED
ALUMINIUM

PLUG

NUTS

BOX WRENCH

SCREWDRIVER

NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES ONLY
THROUGH FADINI ACCESSORIES. NO WARRANTY IS
ACKNOWLEDGED BY THE MANUFACTURER IN CASE THAT
OTHER ACCESSORIES ARE USED OR NON CONFORMING
APPLICATIONS ARE MADE WITHOUT THE MANUFACTURER’S
APPROVAL.

NOTE WELL. For special applications, ie. to switch on lights
-  CCTV etc..., SOLID STATE RELAYS are recommended to be
used only. Standard relays would affect the micro-processor.

ALL OPERATIONS

OPEN, CLOSE

& REVERSE

RADIO CONTACT

PULSE TWICE CONSECUTIVELY

TO OPEN BOTH GATE LEAFS

PEDESTRIAN MODE

ONE PULSE OPENS

ONE GATE LEAF ONLY

Should more pairs of photocells be

required than the recommended

quantity

, fit an auxiliary transformer

outside the control box.

= PHOTOCELLS 2nd P

A

IR=

INSIDE PHOTOCELLS N.C. CONT

ACT

.

IF OBSTRUCTED, THEY PREVENT THE

GA
TES FROM OPENING, REVERSE GA

TE

DIRECTION DURING CLOSE CYCLE.

TERMINALS FOR THE
CONNECTION OF THE
PUSH BUTTONS PULIN 3

RADIO CONTROL
PLUG-IN CARD SUPPORT

24 V OUTPUT

1

°

 CHANNEL

DWELL TIME

MOTOR RUN TIME
OPEN & CLOSE

ON TO “0” THE DELAY
IS OUT OF SERVICE

MICRO PROCESSOR

LEAF DELAY
TIMER
CLOSE

CAPACITORS

1 AMP.
FUSE: 24 V OUTPUT
TERMINALS 12-13

630 mA
FUSE

630 mA FUSE
FLASHING LAMP

5 AMP. FUSE

ELECTRIC MOTORS
SINGLE-PHASE

FLASHING LAMP

230 V - 25 W max.

230 V SINGLE-PH.

SUPPL

Y VOL

TAGE

COMMON

COMMON

N.C. CONT

ACT

PHOTO CELLS

STOP SWITCH N.C. CONT

ACT

24 V OUTPUT

A.C.

MAX. PERMITTED LOAD:

2 P
AIRS PHOTOCELLS

1 RADIO RECEIVER

OPEN SWITCH N.O. CONT

ACT

COMMON

VOL

TAGE OUTPUT

ELECTRIC LOCK SUPPL

Y

SAFETY CONT

ACT N.C.

CLOSE SWITCH N.O. CONT

ACT

RADIO CONT

ACT N.O.

COMMON

24 V INDICA

TOR 3 W MAX.

+

+

+

26
27
28

CLOSE N.O. CONTACT

OPEN N.O. CONTACT

COMMON

STOP N.C. CONTACT

RADIO CONTACT

TERMINAL BOARD

ELECTRICAL CONNECTIONS
KEYSWITCH PRIT 19

12

3

4

STOP

OPEN

CLOSE

COMMON

TERMINAL BOARD

PRIT 19

1 2 3 4 5 6 7 8 9 10 11 12 13

Содержание HINDI 880 SPRINT

Страница 1: ...This must be properly removed from the terminal board in the junction box Switch off the mains switch before removing the junction box cover where the electric cable of HINDI 880 is terminated All th...

Страница 2: ...ULIC PISTON Time for one stroke 24 s Pump flow rate P5 1 4 l min Stroke 280 mm Cylinder bore 45 mm Piston shaft 20 mm Thrust power 3 000 Nm Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Oi...

Страница 3: ...CAN BE CONSIDERED TO BE INCLUDED BETWEEN 90 AND 100 mm BUT THIS DISTANCE IS NOT APPLICABLE TO ALL INSTALLATIONS GEOMETRY REQUIRED FOR THE MODEL 894 895 896 THE SUM OF A B MUST TOTAL THE PISTON STROKE...

Страница 4: ...ONNECTION DIAGRAM FOR SWING GATES ELPRO 13 exp INSTRUCTIONS FOR THE INSTALLATION OF HINDI 880 AN ELECTRO HYDRAULIC OPERATOR TWO WAY LOCKING IN OPEN AND CLOSE GATE POSITION 1 2 3 4 5 6 7 8 9 10 11 12 1...

Страница 5: ...4 PIC 5 PIC 6 MANUAL RELEASE ANTI CLOCKWISE ONE COMPLETE TURN RELEASE TIGHTEN TO LOCK 1625 3rd OPERATION 1st OPERATION 2nd OPERATION DETAIL OF THE VALVE ENCLOSURE ALL THE VALVES ARE IN ONE BODY SPECI...

Страница 6: ...The gate with the electric lock must open 5 degrees more than the other one REAR END BLOCK WITH FIXING PARTS RELEASE KEY REMOVABLE FOR EXTRA SECURITY REF No 1625 TWO WAY LOCKING DEVICE SAFETY PRESSURE...

Страница 7: ...The gate with the electric lock must open 5 degrees more than the other one REAR END BLOCK WITH FIXING PARTS RELEASE KEY REMOVABLE FOR EXTRA SECURITY REF No 1625 TWO WAY LOCKING DEVICE SAFETY PRESSURE...

Страница 8: ...4 PIC 5 PIC 6 MANUAL RELEASE ANTI CLOCKWISE ONE COMPLETE TURN RELEASE TIGHTEN TO LOCK 1625 3rd OPERATION 1st OPERATION 2nd OPERATION DETAIL OF THE VALVE ENCLOSURE ALL THE VALVES ARE IN ONE BODY SPECI...

Страница 9: ...ONNECTION DIAGRAM FOR SWING GATES ELPRO 13 exp INSTRUCTIONS FOR THE INSTALLATION OF HINDI 880 AN ELECTRO HYDRAULIC OPERATOR TWO WAY LOCKING IN OPEN AND CLOSE GATE POSITION 1 2 3 4 5 6 7 8 9 10 11 12 1...

Страница 10: ...CAN BE CONSIDERED TO BE INCLUDED BETWEEN 90 AND 100 mm BUT THIS DISTANCE IS NOT APPLICABLE TO ALL INSTALLATIONS GEOMETRY REQUIRED FOR THE MODEL 894 895 896 THE SUM OF A B MUST TOTAL THE PISTON STROKE...

Страница 11: ...ULIC PISTON Time for one stroke 24 s Pump flow rate P5 1 4 l min Stroke 280 mm Cylinder bore 45 mm Piston shaft 20 mm Thrust power 3 000 Nm Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Oi...

Страница 12: ...This must be properly removed from the terminal board in the junction box Switch off the mains switch before removing the junction box cover where the electric cable of HINDI 880 is terminated All th...

Отзывы: