Installation manual Vaska
9 <
<
<
<
Measuring the inlet pressure:
Close the shutoff valve. Turn the
measuring nipple “A” (fig. 1.0) a few turns
to open and connect a measuring hose to
the gas valve.
Take this measurement when the
fireplace runs at high and low settings.
Do not use the device if the inlet pressure
deviates (+20% or -20%).
Measuring the burner pressure:
Check the burner pressure only with proper inlet
pressure.
Turn measuring nipple “B” (see fig. 1.0)
some turns open and connect a measuring
hose to the gas valve.
The pressure must correspond to the
value indicated in the technical
specifications of this manual. In case of
deviation contact the manufacturer.
Please note!
Close both pressure measuring nipples and
check for gas leakage.
Check ignition and burner
Ignite the fireplace by using the remote control as
described in the user manual and test all burner
possibilities.
7.1
Checking the flame image
Let the fireplace burn for at least 20 minutes at
highest setting and check the flame for:
flame distribution;
colour of the flames.
If one or both points are not acceptable then
check:
The position of the logs and/or the
amount of ash material.
The pipe connections for leaks.
(in case of blue flames);
That the correct flue restrictor is fitted
(see fig. 1.5);
The outlet:
o
Wall terminal has the correct
position and side up;
o
Roof terminal has the correct
position.
If the maximum lengths of the flue gas
outlet is not exceeded.
8
Instructions for client
Recommend that the fire should be
checked annually by a qualified specialist
to ensure the safe use and to guarantee a
long service life.
Provide instructions on the operation of:
o
the appliance;
o
the remote control;
o
if present, the App and its
settings.
Give advice and instructions on care and
cleaning of the glass:
Emphasize the danger of fingerprint burns
at the glass.
Handover to customer:
o
installation manual;
o
user manual;
o
decoration instruction card;
o
suction cups;
o
sample Faber glass polish.
9
Annual maintenance
Check
Check and clean if necessary:
the combustion chamber;
the burner
the pilot flame;
the wooden logs for breakage;
the glass(es);
the outlet.
Replace ash material and/or glass granulate if
necessary.
Cleaning
Remove the front glass (see chapter 5).
You can clean the glass with Faber glass polish.
This is a specially formulated cleaning agent that
can be ordered at authorized Faber dealers.
Never use aggressive cleaning agents or abrasive
products.
Please note!
Avoid fingerprints on the glass; these are no
longer removable once the fire is used.
Now carry out check-up as described in chapter 7.
Содержание Vaska
Страница 1: ...Installation manual Vaska ENG 40010627 2011...
Страница 2: ...Installation manual Vaska 1...
Страница 3: ...Installation manual Vaska 2...
Страница 4: ...Installation manual Vaska 3 1 0 1 1 1 2a 1 2b...
Страница 5: ...Installation manual Vaska 4 1 3a 1 3b 1 3c 1 4...
Страница 6: ...Installation manual Vaska 5 1 5...
Страница 13: ...Installation manual Vaska 12 12 Examples flue materials...
Страница 18: ...Installation manual Vaska 17 16 Troubleshooting guide...
Страница 19: ...Installation manual Vaska 18...
Страница 20: ...Installation manual Vaska 19 17 Dimensional drawings 17 1 Vaska...
Страница 21: ...Installation manual Vaska 20 17 2 Position gas connection...
Страница 22: ...Installation manual Vaska 21 18 Decoration instruction card...
Страница 23: ...Installation manual Vaska 22...
Страница 24: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen...