Faber Torch framed Скачать руководство пользователя страница 11

 

<

 

<

 

<

 

<

 

UK

IRL 

6.1.3

 

Burner (dis)assembly 

 

Turn off  the gas supply to the control valve 

 

Remove the glass and grid 

 

Detach the gas connection 

 

Unscrew the two screws under the burner assembly and remove it from the 

combustion chamber (see figure 7) 

 

The pilot can be removed by removing the screw in the centre of the pilot 

 

Replace parts as necessary and re-assemble 

 

6.2

 

Combustion test 

A BS7967 combustion analysis check should be carried out using an analyser to 

MantleBS7927 positioned in the outlet. 

The performance of the appliance should be checked 

6.2.1

 

Procedure for performance test 

Ignite the fire and run at FULL for a minimum of 15 minutes 

Record the Carbon Dioxide (CO2) reading at the outlet, most analysers will display this as a 

percentage (%) 

Repeat test for Carbon Monoxide (CO), this will be measured in Parts Per Million (ppm); 

Calculate the combustion ratio (CO/CO2). 

 

 

This combustion ratio of the emitted gasses should not exceed 0.0015 

 

 

Ratio =      CO (ppm)    _ 
             CO2 (%) x 1000 

Содержание Torch framed

Страница 1: ...Torch framed Installation Guide IRL UK 40010567 0602 ...

Страница 2: ...1 1 2 3 4 ...

Страница 3: ... 2 5 6 7 ...

Страница 4: ...ns of the appliance 3 4 Installation instructions 4 4 1 Gas connection 4 4 2 Installing the appliance 4 5 Commissioning Functional checks 5 5 1 Pilot ignition check 5 5 2 Check functional burner and pilot burner 5 6 Servicing 6 6 1 Routine servicing 6 6 2 Combustion test 7 Appendix A Spare parts 8 Apppendix B Technical data 9 ...

Страница 5: ...ions with the user This guide covers the following appliances Torch framed Torch framed Propane LPG Special features Special patented Torch flame technology Multi vent appliance for wall connection only Remote Control option available Meets the essential requirements of the European Gas Appliance Directive GAD and carries the CE mark ...

Страница 6: ...fety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm or children in the same room of the appliance T...

Страница 7: ...ements The rear wall must be of a non combustible material see figure 1 for drilling patern Minimum distance from the back of the appliance to the wall has to be 22mm This gap should be maintained by the mounting brackets which fit flush onto the rear wall The plaster has to be resistant to a high temperature Therefore use plaster materials especially made for this to prevent discolouring min 100 ...

Страница 8: ...it Then you can go on installing a fixed or flexible connection This has to be CE certified When installed as described above the burner can always be disassembled for servicing 4 2 Installing the appliance Check if the wall is sufficiently level If necessary improve it Insulate the back wall if necessary with promatect or comparable inflammable material Position the saddle and mark the hole centr...

Страница 9: ...Check if the measured pressure is the same as the prescribed pressure Perform this measuring when the appliance burns on full capacity and when only the pilot ignition burns When the pressure is too low check if the gas pipes are made of material with the right diameter When the pressure is too high more than 5 mBar overpressure you can t install the appliance and you should contact your gas compa...

Страница 10: ...ection 6 1 1 Cleaning the glass Depending on the intensity of use you can get a deposit on the glass Normally this can be removed with an ordinary dry towel If necessary special ceramic glass cleaner ceramic cook top cleaner can be used To clean the glass Remove the Front Frame Remove the glass in it s frame Clean the glass Handle the glass with clean hands wear gloves if possible To fit the glass...

Страница 11: ...BS7967 combustion analysis check should be carried out using an analyser to MantleBS7927 positioned in the outlet The performance of the appliance should be checked 6 2 1 Procedure for performance test Ignite the fire and run at FULL for a minimum of 15 minutes Record the Carbon Dioxide CO2 reading at the outlet most analysers will display this as a percentage Repeat test for Carbon Monoxide CO th...

Страница 12: ...ass 04510930 04510930 Burner Natural gas 20861096 Burner Propane 20532935 Remote assembly 20604500 20604500 Gasvalve 37003098 37003098 HT Lead 06017301 06017301 Spark electrode 06006500 06006500 Pilot Burner assembly NG 37001030 37001030 Thermocouple 37002041 37002041 ...

Страница 13: ...20 37 Gasrate 15 C 1013 bar m3 h kg h 0 260 0 16 Injector size mm 1 20 0 8 Pilot assembly Type SIT 145 SIT 145 Code Nr 30 Nr 15 Outlet terminal size mm 150 100 150 100 Gas control Mertik GV36 Mertik GV36 Remote control Mertik G30 ZRPS 800 Mertik G30 ZRPS 800 Batteries remote 1x 9V MN1604 6LR61 1x 9V MN1604 6LR61 Batteries receiver 4x 1 5V LR03 Alkaline 2x 1 5V LR03 Alkaline Gas connection 8mm nut ...

Страница 14: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 40010567 0602 ...

Отзывы: