Faber theMOOD Скачать руководство пользователя страница 9

 

8 < 

<

 

<

 

<

 

 

Ordered separately and included: 
Box with exhaust pipe. 
 

5

 

Installation requirements 

5.1

 

Installation of theMOOD 

Mount the fireplace leveled on a flat solid 
surface. 
Install the control unit in the field of vision of 
the outdoor fireplace and in such a way that 
this is always protected from sunlight and rain 
and out of the reach of children.  

5.2

 

Electrical connection and cabling  

The control unit has standard a cable with a 
length of 8 meters.

 

With a connection for battery supply and for 
the controlling. 

 
Attention: The cables MAY NOT be 
extended.  
Longer cables can pick up environmental 
signals that can switch the appliance 
uncontrolled On or Off. 

5.3

 

Gas connection 

● 

The gas connection must comply with the 
local standards.

 

 

6

 

Installation instruction  

6.1

 

General 

● 

Before installing the fireplace, the 
exhaust connector must be mounted first, 
place the exhaust connector on the 
appliance and fix it with the 4 supplied 
nuts. (see fig. 1.3) 

● 

ATTENTION: the temperature of the 
exhaust pipe can become  approx. 400°C, 
keep this in mind if the exhaust pipe will 
pass through a lean-to roof. 

o

 

Install the outdoor fireplace 
leveled on a solid surface, if this 
is not present then create a 
foundation The mounting holes 
are located into the leg of the 
appliance (see fig. 1.2)  

o

 

First remove the cover plate by 
means of 4 screws (see fig. 1.1 

B

6.2

 

Installation gas connection 

Install a two-piece gas tap or a flat 
connection as close as possible to the 
connection (pipe nipple) of the fireplace. So 
that for service and maintenance the burner 
can be disassembled. (See fig. 1.4 and 1.5) 

 
The appliance can be connected to both the 
gas network and a gas cylinder.  
 
The fireplace should be installed in 
accordance with these installation 
instructions and applicable national and local 
regulations. 
 
At an initial commissioning of a new 
installation you should remove the air from 
the gas pipe  

 
Inspect the complete gas connection for 
leaks.

  

 

TIP: For both natural gas or propane,  
A flexible hose with gas (insert) socket is 
available at Faber.  
 
Please, contact your dealer for further 
information. (Mertik Plug 1 connection) 

 

Tips for safe use of gas cylinders 

● 

Gas cylinders always must be standing 
upright, both during use and transport.  

● 

Place the cylinder at a minimum distance 
of 1 meter from the fireplace.  

● 

Always use a pressure regulator between 
the cylinder and the appliance. Replace 
the pressure regulator every 5 years. 

● 

Use an approved regulator according to 
local regulations. Pay attention to the 
correct supply pressure!  

● 

Use only approved gas connection hoses 
and replace it every 2 years.  

● 

NEVER fill gas cylinders with LPG. Leave 
the filling of gas cylinders to an 
authorized filling station.  

● 

Replacing the gas cylinder: 
 

1.

 

Make sure the gas cylinder is placed in a 
well ventilated area, away from ignition 
sources (candles, cigarettes or other heat 
sources). 

2.

 

Connect the pressure regulator to the gas 
cylinder. 
Use a good fitting wrench to unscrew the 
pressure regulator.  
check the gasket ring of the pressure 
regulator. 

3.

 

You can now replace the gas cylinder. 
Securing the pressure regulator goes in 
reverse order. 
 
Check all connections for possible gas 
leakages.  
You can do this with: 

● 

brush with liquid detergent and 
water.  

● 

spray. 

Содержание theMOOD

Страница 1: ...Outdoor fire theMOOD Installation Instruction User Manual 40011460 1326 ...

Страница 2: ...1 L 1 1 1 2 1 3 1 4 1 5 4X A B ...

Страница 3: ...2 L 1 6 2 1 2 2 ...

Страница 4: ...3 L 2 3 2 4 2 5 2 6 ...

Страница 5: ...4 L Min distance to combustible materials 50cm 30cm 0cm Flue gas Exhaust pipe total X Zone A X Zone B X 2 7 ...

Страница 6: ...5 L 3 1 3 2 3 3 3 4 3 5 3 6 ...

Страница 7: ...6 L 4 1 4 2 4 3 4 4 ...

Страница 8: ... guaranteed off 0 We advise to install the outdoor fireplace somewhat sheltered Advantages Less wind sensitive and better stability Intuitively more heat emission The use of this outdoor fireplace in a confined space is LIFE THREATENING and is PROHIBITED An installation area must have at least 25 wall surface open to ensure a good ventilation see detail drawing 2 5 In extreme weather conditions we...

Страница 9: ...ice and maintenance the burner can be disassembled See fig 1 4 and 1 5 The appliance can be connected to both the gas network and a gas cylinder The fireplace should be installed in accordance with these installation instructions and applicable national and local regulations At an initial commissioning of a new installation you should remove the air from the gas pipe Inspect the complete gas conne...

Страница 10: ...ving the burner unit the following points must be carried out 1 permanently remove the burner plate screws see fig 2 1 2 ensure a minimum of 50 cm extra cable length in the casing or breast construction 6 6 Installing the control unit Refer to Installation Requirements sections 5 1 5 2 and figures 3 1 up to 3 6 Determine the location for the control unit Pull the cables through the opening of the ...

Страница 11: ... lifecycle Point the customer on the service life of the gas hose and pressure regulator Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burnt in fingerprints Instruct the customer on the operation of the appliance Hand over to the client o Installation Instructions o Suction lifters o Log set card 10 Annual maintenance 10 1 Check In case of build i...

Страница 12: ...31 Load Hi kW 12 4 12 4 12 4 Inlet pressure mbar 20 30 37 Gas flow rate at full load M3 h 1 303 0 374 0 496 At 15 C and 1013 mbar gr h 940 930 Burner pressure at full load mbar 13 18 2 24 7 Nozzle main burner mm ST1100 ST500 ST500 Pilot light OP9040 OP9226 OP9226 Gas control valve GV60 GV60 GV60 batteries 4x AA 1 5V 4x AA 1 5V 4x AA 1 5V ...

Страница 13: ...12 L 12 Dimensional drawing ...

Страница 14: ...13 L ...

Страница 15: ...14 L ...

Страница 16: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: