Faber theMOOD Скачать руководство пользователя страница 8

 

7 < 

<

 

<

 

<

 

 

 

1

 

Introduction 

We urgently advice to read this Installation 
and User Instructions thoroughly. 
This appliance complies with the guidelines 
for European gas appliances (gas appliances 
directive) and bears the CE mark. 
Keep this Installation and User Instructions for 
future reference. 
 
 

2

 

Product Description 

“theMOOD” is a gas appliance made of Corten 
steel with a single-walled flue pipe of Ø 
150 mm and is only intended for outdoor use. 
The combustion air enters through the bottom 
and through the gaps into the appliance. 

2.1

 

Corten Steel 

● 

Also known as weathering steel, is a 
metal alloy consisting of iron to which 
copper, phosphorus, silicon, nickel and 
chromium are added. Characteristic of 
Corten steel is both the brown orange rust 
color and the durability. The lifetime is so 
long because the first corrosion layer 
(patina) prevents further corrosion caused 
by rust. 

● 

The color

  

of the Corten steel develops further and 
each product is unique. The final 
appearance,-orange, terra, brown-, 
depends on conditions such as humidity, 
temperature and the extent to which the 
product is exposed to the weather 
conditions.  
The steel gets its final color after about 2 
years! 
Keep in mind, that during the formation 
of this “rust layer” on both the inside and 
outside of the fireplace rusty water 
comes from the material, this will leave 
traces.  
 

● 

ATTENTION:

 This “rust layer” (patina) is 

the protective layer of the steel, if this is 
removed the process will start over again.  
For example, the presence of wet leaves 
on Corten steel can leave spots behind on 
steel. 

 

3

 

Safety instructions 

● 

Operation area of the fireplace is 
guaranteed off   0°  

● 

We advise to install the outdoor fireplace 
somewhat sheltered. 
Advantages:  

● 

Less wind sensitive and better 

stability. 

● 

Intuitively more heat emission. 

● 

The use of this outdoor fireplace in a 
confined space is LIFE-THREATENING 
and is PROHIBITED. 
An installation area must have at least 
25% wall surface open to ensure a good 
ventilation, see detail drawing 2.5. 

● 

In extreme weather conditions we advise 
to disassemble the flue pipe from the 
fireplace and to cover the exhaust 
connector. 

● 

Close the gas tap or pressure regulator 
after using the outdoor fireplace. 

● 

The outdoor fireplace should be installed 
and annually checked in accordance with 
these installation instructions and 
applicable national and local regulations. 

● 

Check whether the data on the 
registration plate match the local type of 
domestic gas and pressure. (for the 
location of the identification plate, see 
fig. 1.1 

A

● 

Do not put any combustible materials, 
additional imitation logs or glowing coals 
on the burner or in the combustion 
chamber.  

● 

The settings and the construction of the 
outdoor fireplace must not be changed! 

● 

The outdoor fireplace has been designed 
for ambience and heating purposes. This 
means that all surfaces, including the 
glass can get approx. 250°C and the 
exhaust pipe approx. 400°C. (Exceptions 
to this are the control knobs) 

● 

Do not place any combustible materials 
within 0.5 m of the radiation a

ria

 of the 

glass.

 (See also Installation Instruction)

 

 

4

 

Unpacking the appliance 

Inspect theMOOD for any transport damage. 
Please, report transport damage always at 
your supplier. 
You will find: 

1.

 

Documents.  

A.

 

Instruction manual 

B.

 

Warranty Card 

C.

 

Log set card 

2.

 

Suction Lifters.  

3.

 

Glass. 

4.

 

Imitation log set with chips or 
pebbles. 

5.

 

Control unit. 

6.

 

Exhaust Connector. 
 

Not included: 
1.  Mounting material. 
2.  Pressure regulator. 
 

Содержание theMOOD

Страница 1: ...Outdoor fire theMOOD Installation Instruction User Manual 40011460 1326 ...

Страница 2: ...1 L 1 1 1 2 1 3 1 4 1 5 4X A B ...

Страница 3: ...2 L 1 6 2 1 2 2 ...

Страница 4: ...3 L 2 3 2 4 2 5 2 6 ...

Страница 5: ...4 L Min distance to combustible materials 50cm 30cm 0cm Flue gas Exhaust pipe total X Zone A X Zone B X 2 7 ...

Страница 6: ...5 L 3 1 3 2 3 3 3 4 3 5 3 6 ...

Страница 7: ...6 L 4 1 4 2 4 3 4 4 ...

Страница 8: ... guaranteed off 0 We advise to install the outdoor fireplace somewhat sheltered Advantages Less wind sensitive and better stability Intuitively more heat emission The use of this outdoor fireplace in a confined space is LIFE THREATENING and is PROHIBITED An installation area must have at least 25 wall surface open to ensure a good ventilation see detail drawing 2 5 In extreme weather conditions we...

Страница 9: ...ice and maintenance the burner can be disassembled See fig 1 4 and 1 5 The appliance can be connected to both the gas network and a gas cylinder The fireplace should be installed in accordance with these installation instructions and applicable national and local regulations At an initial commissioning of a new installation you should remove the air from the gas pipe Inspect the complete gas conne...

Страница 10: ...ving the burner unit the following points must be carried out 1 permanently remove the burner plate screws see fig 2 1 2 ensure a minimum of 50 cm extra cable length in the casing or breast construction 6 6 Installing the control unit Refer to Installation Requirements sections 5 1 5 2 and figures 3 1 up to 3 6 Determine the location for the control unit Pull the cables through the opening of the ...

Страница 11: ... lifecycle Point the customer on the service life of the gas hose and pressure regulator Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burnt in fingerprints Instruct the customer on the operation of the appliance Hand over to the client o Installation Instructions o Suction lifters o Log set card 10 Annual maintenance 10 1 Check In case of build i...

Страница 12: ...31 Load Hi kW 12 4 12 4 12 4 Inlet pressure mbar 20 30 37 Gas flow rate at full load M3 h 1 303 0 374 0 496 At 15 C and 1013 mbar gr h 940 930 Burner pressure at full load mbar 13 18 2 24 7 Nozzle main burner mm ST1100 ST500 ST500 Pilot light OP9040 OP9226 OP9226 Gas control valve GV60 GV60 GV60 batteries 4x AA 1 5V 4x AA 1 5V 4x AA 1 5V ...

Страница 13: ...12 L 12 Dimensional drawing ...

Страница 14: ...13 L ...

Страница 15: ...14 L ...

Страница 16: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: