9 < 

<

 

<

 

<

 

 

● 

gas leak detector. 

if bubbles appear, you know that there is a 
leak.  

● 

Attention: Make the checked couplings 
always dry after inspection.  

6.3

 

Installing exhaust pipe  

● 

Before connecting the exhaust pipe to the 
connector the resistor tabs must be bent 
outward. 
(see fig. 1.6) repeat this if the exhaust 
pipe comes loose. 

● 

For TheMOOD a maximum flue length of 
1.5 m applies, if the exhaust pipe can be 
bracketed then this length can be 
extended up to 2 meters. Extension pipes 
(1 m.) can be ordered from your dealer. 

● 

When installed under a lean-to roof, at 
least 1 m. space between the top of the 
exhaust pipe and the lean-to roof is 
required. Take in account any 
discoloration of materials under the lean-
to roof. 

6.4

 

Free-standing application 

● 

Refer to Installation Requirements 
chapter 5 and the Installation Instructions 
section 6.1 General. 

● 

The minimum distance to combustible 
materials is 30 cm on the sides and the 
back of the appliance (see fig. 2.7A). In 
the radiation aria of the glass a distance 
of 50 cm should be observed. (see 
fig. 2.7B) 

6.5

 

Build in 

● 

Refer to Installation Requirements 
chapter 5 and the Installation Instructions 
section 6.1 General. 

● 

Due to the high temperatures of the 
fireplace, it should only be built into 
NON-FLAMMABLE materials. (see fig. 2.7) 

● 

Don’t let the casing or breast construction 
rest on the fireplace. 

● 

For the proper functioning of the 
fireplace the casing or breast construction 
should be provided with a ventilation 
opening at the underside of a minimum of 
200 cm

2

 and the space above the 

fireplace should be open for ventilation. 
(see fig. 2.6) 

● 

To facilitate removing the burner unit the 
following points must be carried out: 
1.

 

permanently remove the burner plate 

screws. (see fig. 2.1)  

2.

 

ensure a minimum of 50 cm extra 

cable length in the casing or breast 
construction. 

6.6

 

Installing the control unit 

● 

Refer to Installation Requirements 
sections 5.1/5.2 and figures 3.1 up to 3.6. 

● 

Determine the location for the control 
unit. 

● 

Pull the cables through the opening of the 
surface-mounted socket. (see fig. 3.2) 

● 

Screw the surface-mounted socket on the 
final spot. 

● 

Make sure you have 12 cm cable length in 
the surface-mounted socket for replacing 
the batteries. 

● 

Insert the metal cable relief. (see fig. 
3.4) 

● 

Connect the switch with the cable and 
insert the plug into the terminal. (see 
fig. 3.3) 

● 

Connect the battery holder with the cable 
and insert the batteries into the holder. 
(see fig. 3.5) 

● 

Screw the front panel on the surface-
mounted socket. (see fig. 3.6) 

6.7

 

Replacing/inserting batteries 

The battery holder is integrated into the 
control unit. (see fig. 3.5 and 3.6) 

● 

Unscrew the front plate.  

● 

Remove the battery holder. 

● 

Insert 4 pieces of AA/LR6 Alkaline 

long live batteries.  

● 

Replace the battery holder and mount 

the front plate. 

6.8

 

Removing glass 

● 

Place the suction lifters on the glass and 
lift the glass until it is free of the bottom, 
now pull the bottom of the glass forward. 
(See fig. 4.1 and fig. 4.2) 

 
To replace the glass repeat the process in 
reverse order. 
 
Clean all fingerprints on the glass; otherwise 
they will burn in once the fireplace is used. 
 
The glass is placed slightly loose in the slot by 
default.  
 

7

 

Placing decoration material 

Do not add different or more materials to the 
combustion chamber. 

Always keep the pilot flame free from 
decorative materials! 
 

● 

Place the logs set and chips or 

pebbles over the burner and cover 
plate. (see fig. 4.3/4.4 or the Log set 

Содержание theMOOD

Страница 1: ...Outdoor fire theMOOD Installation Instruction User Manual 40011460 1326 ...

Страница 2: ...1 L 1 1 1 2 1 3 1 4 1 5 4X A B ...

Страница 3: ...2 L 1 6 2 1 2 2 ...

Страница 4: ...3 L 2 3 2 4 2 5 2 6 ...

Страница 5: ...4 L Min distance to combustible materials 50cm 30cm 0cm Flue gas Exhaust pipe total X Zone A X Zone B X 2 7 ...

Страница 6: ...5 L 3 1 3 2 3 3 3 4 3 5 3 6 ...

Страница 7: ...6 L 4 1 4 2 4 3 4 4 ...

Страница 8: ... guaranteed off 0 We advise to install the outdoor fireplace somewhat sheltered Advantages Less wind sensitive and better stability Intuitively more heat emission The use of this outdoor fireplace in a confined space is LIFE THREATENING and is PROHIBITED An installation area must have at least 25 wall surface open to ensure a good ventilation see detail drawing 2 5 In extreme weather conditions we...

Страница 9: ...ice and maintenance the burner can be disassembled See fig 1 4 and 1 5 The appliance can be connected to both the gas network and a gas cylinder The fireplace should be installed in accordance with these installation instructions and applicable national and local regulations At an initial commissioning of a new installation you should remove the air from the gas pipe Inspect the complete gas conne...

Страница 10: ...ving the burner unit the following points must be carried out 1 permanently remove the burner plate screws see fig 2 1 2 ensure a minimum of 50 cm extra cable length in the casing or breast construction 6 6 Installing the control unit Refer to Installation Requirements sections 5 1 5 2 and figures 3 1 up to 3 6 Determine the location for the control unit Pull the cables through the opening of the ...

Страница 11: ... lifecycle Point the customer on the service life of the gas hose and pressure regulator Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burnt in fingerprints Instruct the customer on the operation of the appliance Hand over to the client o Installation Instructions o Suction lifters o Log set card 10 Annual maintenance 10 1 Check In case of build i...

Страница 12: ...31 Load Hi kW 12 4 12 4 12 4 Inlet pressure mbar 20 30 37 Gas flow rate at full load M3 h 1 303 0 374 0 496 At 15 C and 1013 mbar gr h 940 930 Burner pressure at full load mbar 13 18 2 24 7 Nozzle main burner mm ST1100 ST500 ST500 Pilot light OP9040 OP9226 OP9226 Gas control valve GV60 GV60 GV60 batteries 4x AA 1 5V 4x AA 1 5V 4x AA 1 5V ...

Страница 13: ...12 L 12 Dimensional drawing ...

Страница 14: ...13 L ...

Страница 15: ...14 L ...

Страница 16: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: