Annual maintenance 

 
Check

 

Check and clean if necessary: 

 

the combustion chamber; 

 

the burner 

 

the pilot flame; 

 

the wooden logs for breakage; 

 

the glass(es); 

 

the outlet. 

 
Replace ash material if necessary. 
Cleaning 
Remove the front glass (see chapter 5). 
You can clean the glass with Faber glass polish.  
This is a specially formulated cleaning agent that 
can be ordered at authorized Faber dealers. 
Never use aggressive cleaning agents or abrasive 
products. 
 

 

Please note! 
Avoid fingerprints on the glass; these are no 
longer removable once the fire is used. 

 
Now carry out check-up as described in chapter 7. 
 
For an extensive maintenance instruction 
"maintenance protocol gas fires" see: 

 

10

 

Conversion to other gas type 

This can only be done by replacing the burner. To 
do so, please contact your dealer. Always provide 
the type and serial number of the appliance when 
ordering. 

11

 

Flue calculation 

A simple way to calculate whether the exhaust 
configuration is possible in combination with your 
fireplace, use the “Faber Flue App V2”: 

 
 
 
 

This is available free of charge and can be 
downloaded via: 

 

Internet: 
Android and PC (Windows Store, (Windows 10)). 
App Store:  
iPhone, iPad and Mac. 

Google Play: 
Android smart phones and Android tablets. 

 

Alternatively, you can use the calculation sheet 
(see chapter 13). 

 

The options for flue lengths and any flue restrictors 
are defined in a restrictor table, see 11.1. Start 
Length (STL), Total Vertical Height (TVH) and Total 
Horizontal Length (THL) are used in the table. 

 
 

 

Start length (STL): 

The first part that is placed on the 
fireplace and represents a certain value 
(fig. 12.1, 12.2 and 12.3 A, N and F). You 
can find this value in the upper row of the 
restrictor table. 

 

 

Total Vertical Height (TVH): 

TVH is the height difference measured 
from the top of the appliance to the 
outlet. This can be measured or 
determined in the building plan. For 
clarification, see also the TVH indication in 
the drawings (fig. 12.1, 12.2 and 12.3). 

 

 

Total Horizontal Length (THL): 

THL is the Total Horizontal Length and 
consists of elbows and pipes entirely in 
the horizontal plane. See elbows I, K and Q 
and the elements H, J, L, M, P and R  
(fig. 12.1 and 12.2). 

 

 

Horizontal length: 

The Horizontal Length consists of the 
elements H, J, L, M, P and R (fig. 12.1 and 
12.2). 

 

 

Elbows 90° in the horizontal plane: 

Horizontal elbows are elbows entirely in 
the horizontal plane (fig. 12.1, 12.2 and 
12.3 I, K and Q). 
 

 

Elbows 45° or 30° in the horizontal plane. 

Horizontal elbows are elbows entirely in 
the horizontal plane. 

 

 

Elbows 90° vertical to horizontal:  

These are 90° elbows, which proceed from 
horizontal to vertical (fig. 12.2 and 12.3 G, 
O and S). 
 

 

Elbows 45° or 30° vertical to horizontal 
plane: 

These are 30° or 45° elbows vertically 
offset less than 45° (fig. 12.1 B and D). 

Содержание Skive

Страница 1: ...Installation manual Skive ENG 40011134 2010 ...

Страница 2: ...Installation manual Skive 1 ...

Страница 3: ...Installation manual Skive 2 ...

Страница 4: ...Installation manual Skive 3 1 1 1 2 1 3a 1 3b ...

Страница 5: ...Installation manual Skive 4 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 B 1 2 A ...

Страница 6: ...Installation manual Skive 5 2 2 2 3 2 4 2 5 ...

Страница 7: ...able to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space The appliance mu...

Страница 8: ...aber roof outlet with a diameter of 100 150mm C91 existing chimney For an existing chimney use a Faber chimney outlet with a diameter of 100 150mm In this case the existing chimney acts as air inlet an inserted flexible stainless steel pipe discharges the flue gas The top Faber chimney cover plate and the bottom Faber chimney connection set should be airtight Depending on the calculated flue diame...

Страница 9: ...e Never start immediately with length adjustable concentric flue pipe on the appliance Horizontal sections should be installed to allow a slope towards the appliance 3 degrees Built the system from the appliance If this is not possible you can make use of an extendable adapter section For fitting of the flue system the 0 5m length adjustable pipe must be used Make sure that the inner pipe is alway...

Страница 10: ...fications of this manual In case of deviation contact the manufacturer Please note Close both pressure measuring nipples and check for gas leakage Check ignition and burner Ignite the fireplace by using the remote control as described in the user manual and test all burner possibilities 7 1 Checking the flame image Let the fireplace burn for at least 20 minutes at highest setting and check the fla...

Страница 11: ... the calculation sheet see chapter 13 The options for flue lengths and any flue restrictors are defined in a restrictor table see 11 1 Start Length STL Total Vertical Height TVH and Total Horizontal Length THL are used in the table Start length STL The first part that is placed on the fireplace and represents a certain value fig 12 1 12 2 and 12 3 A N and F You can find this value in the upper row...

Страница 12: ...rrect vertical TVH and horizontal length THL In case of an X or if the values are outside the restrictor table the combination is not permitted Then adjust TVH or THL If a value is indicated check that the calculated STL value is not lower than indicated in the restrictor table In this case STL must be adjusted The value found indicates the width of the flue restrictor to be placed 0 means no flue...

Страница 13: ...00 50 00 40 00 30 00 0 00 0 00 x x x x 12 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 13 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 14 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 15 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 16 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 17 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 18 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 19 6...

Страница 14: ...Installation manual Skive 13 12 Examples flue materials ...

Страница 15: ...e length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizontal dir...

Страница 16: ...llation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In case of ro...

Страница 17: ... Energy efficiency index EEI 89 89 89 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Skive Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW Other control options One step hea...

Страница 18: ... outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof ...

Страница 19: ...Installation manual Skive 18 16 Troubleshooting guide ...

Страница 20: ...Installation manual Skive 19 ...

Страница 21: ...Installation manual Skive 20 ...

Страница 22: ...Installation manual Skive 21 17 Dimensional drawings 17 1 Skive ...

Страница 23: ...Installation manual Skive 22 17 2 Position gas connection ...

Страница 24: ...Installation manual Skive 23 17 3 Wall bracket ...

Страница 25: ...Installation manual Skive 24 18 Decoration instruction card ...

Страница 26: ......

Страница 27: ......

Страница 28: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Отзывы: