Faber Skive Скачать руководство пользователя страница 10

 

Installation manual Skive

 

 

9 < 

<

 

<

 

 

Divide the ash material between the logs, 
don’t cover the air intake (perforated 
parts) at the back. 

 

 

Please note! 
Keep the pilot flame free from ash material. 

 

 

Start the fireplace as described in the user 
manual. 

 

Assess whether the flame distribution is 
good. Move or remove any ash material 
to create a nice glow bed. 

 

Install the front glass and check the fire 
image. 

7

 

Checking the installation 

 
Checking for gas leaks 
 
Check with a gas leak finder all connections and 
pipes for gas leakage. 
 
Check primary- and burner pressure 
Check if the primary pressure correspond to the 
data on the rating plate. 
 
Measuring the primary pressure: 

 

Close the shutoff valve. Turn the 
measuring nipple “A” (fig. 1.1) a few turns 
to open and connect a measuring hose to 
the gas valve. 

 

Take this measurement when the 
fireplace runs at high and low settings.  

 

Do not use the device if the pressure 
deviates (+20% or -20%). 

 
Measuring the burner pressure: 
Check the burner pressure only with proper 
primary pressure. 

 

Turn measuring nipple “B” (see fig. 1.1) 
some turns open and connect a measuring 
hose to the gas valve. 

 

The pressure must correspond to the 
value indicated in the technical 
specifications of this manual. In case of 
deviation contact the manufacturer. 
 

 

Please note! 
Close both pressure measuring nipples and 
check for gas leakage. 

 
Check ignition and burner 
Ignite the fireplace by using the remote control as 
described in the user manual and test all burner 
possibilities. 
 
 

7.1

 

Checking the flame image 

Let the fireplace burn for at least 20 minutes at 
highest setting and check the flame for:  

 

flame distribution;  

 

colour of the flames. 
 

If one or both points are not acceptable then 
check:  

 

The position of the logs and/or the 
amount of ash material; 

 

The pipe connections for leaks. 
(in case of blue flames);  

 

That the correct flue restrictor is fitted 
(see fig. 1.7-A); 

 

The outlet: 

o

 

Wall terminal has the correct 
position and side up; 

o

 

Roof terminal has the correct 
position. 

 

If the maximum lengths of the flue gas 
outlet is not exceeded. 

8

 

Instructions for client 

 

Recommend that the fire should be 
checked annually by a qualified specialist 
to ensure the safe use and to guarantee a 
long service life.  

 

Provide instructions on the operation of: 

o

 

the appliance; 

o

 

the remote control; 

o

 

if present, the App and its 
settings. 

 

Give advice and instructions on care and 
cleaning of the glass: 

 

 

Emphasize the danger of fingerprint burns 
at the glass. 

 

Handover to customer: 

o

 

installation manual;  

o

 

user manual; 

o

 

decoration instruction card; 

o

 

suction cups; 

o

 

sample Faber glass polish. 

 

 

Содержание Skive

Страница 1: ...Installation manual Skive ENG 40011134 2010 ...

Страница 2: ...Installation manual Skive 1 ...

Страница 3: ...Installation manual Skive 2 ...

Страница 4: ...Installation manual Skive 3 1 1 1 2 1 3a 1 3b ...

Страница 5: ...Installation manual Skive 4 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 B 1 2 A ...

Страница 6: ...Installation manual Skive 5 2 2 2 3 2 4 2 5 ...

Страница 7: ...able to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space The appliance mu...

Страница 8: ...aber roof outlet with a diameter of 100 150mm C91 existing chimney For an existing chimney use a Faber chimney outlet with a diameter of 100 150mm In this case the existing chimney acts as air inlet an inserted flexible stainless steel pipe discharges the flue gas The top Faber chimney cover plate and the bottom Faber chimney connection set should be airtight Depending on the calculated flue diame...

Страница 9: ...e Never start immediately with length adjustable concentric flue pipe on the appliance Horizontal sections should be installed to allow a slope towards the appliance 3 degrees Built the system from the appliance If this is not possible you can make use of an extendable adapter section For fitting of the flue system the 0 5m length adjustable pipe must be used Make sure that the inner pipe is alway...

Страница 10: ...fications of this manual In case of deviation contact the manufacturer Please note Close both pressure measuring nipples and check for gas leakage Check ignition and burner Ignite the fireplace by using the remote control as described in the user manual and test all burner possibilities 7 1 Checking the flame image Let the fireplace burn for at least 20 minutes at highest setting and check the fla...

Страница 11: ... the calculation sheet see chapter 13 The options for flue lengths and any flue restrictors are defined in a restrictor table see 11 1 Start Length STL Total Vertical Height TVH and Total Horizontal Length THL are used in the table Start length STL The first part that is placed on the fireplace and represents a certain value fig 12 1 12 2 and 12 3 A N and F You can find this value in the upper row...

Страница 12: ...rrect vertical TVH and horizontal length THL In case of an X or if the values are outside the restrictor table the combination is not permitted Then adjust TVH or THL If a value is indicated check that the calculated STL value is not lower than indicated in the restrictor table In this case STL must be adjusted The value found indicates the width of the flue restrictor to be placed 0 means no flue...

Страница 13: ...00 50 00 40 00 30 00 0 00 0 00 x x x x 12 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 13 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 14 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 15 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 16 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 17 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 18 65 00 60 00 50 00 40 00 30 00 0 00 0 00 x x x x 19 6...

Страница 14: ...Installation manual Skive 13 12 Examples flue materials ...

Страница 15: ...e length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizontal dir...

Страница 16: ...llation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In case of ro...

Страница 17: ... Energy efficiency index EEI 89 89 89 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Skive Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW Other control options One step hea...

Страница 18: ... outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof ...

Страница 19: ...Installation manual Skive 18 16 Troubleshooting guide ...

Страница 20: ...Installation manual Skive 19 ...

Страница 21: ...Installation manual Skive 20 ...

Страница 22: ...Installation manual Skive 21 17 Dimensional drawings 17 1 Skive ...

Страница 23: ...Installation manual Skive 22 17 2 Position gas connection ...

Страница 24: ...Installation manual Skive 23 17 3 Wall bracket ...

Страница 25: ...Installation manual Skive 24 18 Decoration instruction card ...

Страница 26: ......

Страница 27: ......

Страница 28: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Отзывы: