Installation guide 

 

ENG 

ENG 

Содержание Relaxed Premium L

Страница 1: ...Relaxed Premium L 40010947 1021 Installation guide ENG ENG ...

Страница 2: ...L 1 1 1 1 2 1 3 1 4 1 5 A ...

Страница 3: ...L 2 2 1 2 2 2 3 2 4 2 5 ...

Страница 4: ...L 3 3 1 3 2 3 3 ...

Страница 5: ... breast 10 4 7 Chimney breast 10 5 Removing the glass 11 6 Placing the decorative material 11 6 1 Imitation logs 11 6 2 Pebbles Greystone 11 7 Checking the installation 12 7 1 Checking the ignition of the pilot burner main burner 12 7 2 Checking for gas leakage 12 7 3 Checking the burner pressure and the pre pressure 12 7 4 Checking the flame picture 13 8 Instructing the client 13 9 Annual mainten...

Страница 6: ...L 5 12 1 Please note only a vertical flue installation 17 13 Technical data 18 14 Dimension of the appliance 19 15 Dimension Ventilation Grills 20 16 Dimension Service Hatch 21 1 Introduction ...

Страница 7: ...g purposes This means that all surfaces of the appliance including the glass can become very hot hotter than 100 C An exception to this are the bottom of the appliance and the controls Do not place any inflammable materials within a of 0 5 m of the radiation of the appliance and ventilation grills Due to natural air circulation of the appliance moisture and volatile components from paint building ...

Страница 8: ...acks etc Recommended drying time for plaster is a minimum of 24 hours per mm of coat applied The false chimney breast and its construction may not rest on the appliance 3 3 Requirements flue system and outlets You should always make use of the materials prescribed by Faber International Ltd Only by using these materials can Faber International Ltd guarantee a proper functioning The outside of the ...

Страница 9: ...ss steel pipe drawn up through the chimney will remove the combustion gas The flexible stainless steel pipe of Ø 100 mm should have a CE mark for temperatures up to 600 Celsius The chimney should comply with the following requirements The diameter of the flue system must be at least 150x150 mm There should be no more than 1 appliance connected to a flue pipe The chimney must be in good condition o...

Страница 10: ...bourhood of the hearth 4 3 Preparation of the appliance Remove the packaging of the appliance Make sure the gas pipes underneath the appliance are not damaged Clear a safe space to store the frame and the glass Remove the frame if necessary and the glass and take the separately wrapped parts out of the appliance Prepare the gas connection to the gas control valve 4 4 Placing the appliance Take the...

Страница 11: ...reast Before constructing the false chimney breast we advise you to perform a function test with the gas hearth as described in chapter 7 checking the installation 4 7 Chimney breast Construct the false chimney breast from non combustible sheet metal in combination with metal profiles or of brickwork aerated concrete bricks Take the grates and the service panel see fig 1 1 and1 2 into account Plac...

Страница 12: ... all the decorative material onto the burner all at once it can be obstructed by dust particles 6 1 Imitation logs Place a number of the chips onto the burner and on the cover plate Place the imitation logs according to instructions see fig 3 1or imitation logs instruction card supplied Divide the remainder of the chips over the burner and the cover plate Avoid a thick layer onto the burner this h...

Страница 13: ...inlet pressure measured agree with the data indicated on the registration plate Measuring the inlet pressure Turn off the gas control tap Open the pressure gauge nipple B see fig 1 3 a few turns and connect a pressure gauge hose to the gas control valve Carry out this measurement when the appliance is on at full gas mark and when it is on the pilot light If the inlet pressure is too high you are n...

Страница 14: ...ll terminal is installed correctly o Roof terminal is fitted and sited correctly The flue system is correctly calculated 8 Instructing the client Recommend that the appliance be serviced annually by a competent person in order to guarantee a safe use and a long lifespan Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burning in fingerprints Instruct...

Страница 15: ...the glass Most of the deposits can be removed with a dry cloth You can use ceramic hob cleaner to clean the glass Note prevent fingerprints on the glass these will be burned into it once the appliance is used and cannot be removed anymore Carry out the check up according to the instructions in chapter 7 checking the installation 10 Conversion to a different type of gas e g propane This can only be...

Страница 16: ...The wall terminal always counts as 1 metre If there is transit under 45 then the real vertical and horizontal lengths should be calculated 11 1 Points of particular interest In case of a wall terminal the entire flue system including the wall terminal should be constructed of 200 130 flue pipes In case of a roof terminal the entire flue system should be constructed of 200 130 flue pipes apart from...

Страница 17: ...d D 1 x 2 m 2 m Total 4 m Count the vertical lengths Flue pipe length A 1 m Roof terminal G 1 m Total 2 m Sample calculation 2 Count the horizontal lengths Flue pipe lengths J L 0 5 0 5 1 m Bends K M 2 2 m 4 m Wall terminal 1 m Total horizontal length 6 m Count the vertical lengths Flue pipe length H 1 m Total 1m ...

Страница 18: ...m restrictor is pre installed 12 1 Please note only a vertical flue installation than the fire most install with the 150 100 mm flue pipe Horizontal 0 1 2 3 4 5 6 0 x x x x x x x 0 5 x 30 30 0 0 x x 1 x 40 40 30 30 0 0 1 5 0 50 50 40 40 30 30 2 30 60 60 50 50 40 40 3 40 65 65 60 60 50 50 4 50 70 70 65 65 60 60 5 55 70 70 70 65 65 65 6 60 75 75 70 70 70 70 7 65 80 75 75 70 70 x 8 70 85 85 80 80 x x...

Страница 19: ...and 1013 mbar gr h 420 450 Burner pressure at full mark mbar 9 2 25 1 30 1 Injector main burner mm ST 500 7x0 79 ST 510 7x0 83 ST 180 7x0 79 ST 160 7x0 83 ST 180 7x0 79 ST 160 7x0 83 Reduced input restraint mm 2 1 1 3 1 3 Pilot assembly SIT 145 SIT 145 SIT 145 Code Injector Nr 36 Nr 23 Nr 23 Flue size mm 200 130 200 130 200 130 Gas control valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical...

Страница 20: ...L 19 14 Dimension of the appliance ...

Страница 21: ...L 20 15 Dimension Ventilation Grills ...

Страница 22: ...L 21 16 Dimension Service Hatch ...

Страница 23: ...22 L ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...