Faber MatriX 800/500 I H Скачать руководство пользователя страница 1

 

Installation manual 

MatriX 800/500 I,II,III H 
MatriX 800/650 I,II,III H 

ENG 

 

 

 

 

 
 
 
 
 
 
 

40012077-2128 

 

 

Содержание MatriX 800/500 I H

Страница 1: ...Installation manual MatriX 800 500 I II III H MatriX 800 650 I II III H ENG 40012077 2128 ...

Страница 2: ...Installation manual MatriX 800 500 650 I II III H 1 ...

Страница 3: ...Installation manual MatriX 800 500 650 I II III H 2 ...

Страница 4: ...Installation manual MatriX 800 500 650 I II III H 3 1 0 1 1 1 3 1 2 1 4 ...

Страница 5: ...Installation manual MatriX 800 500 650 I II III H 4 1 5 1 6 1 7 1 8 1 9a 1 9b 1 9c 1 9d 1 9e 1 9f 1 9g 1 9h ...

Страница 6: ...Installation manual MatriX 800 500 650 I II III H 5 2 0 2 1 2 2 2 3 2 4a 2 4b ...

Страница 7: ...Installation manual MatriX 800 500 650 I II III H 6 2 5 2 6 2 7 2 8 3 0 3 1 3 2 3 3 ...

Страница 8: ...Installation manual MatriX 800 500 650 I II III H 7 3 4 3 5 3 6 3 7 3 8 ...

Страница 9: ...Installation manual MatriX 800 500 650 I II III H 8 3 9 4 0 4 1 ...

Страница 10: ...dified without written authorization of Glen Dimplex Benelux B V 2 Safety instructions Please note It is advisable to always install a screen for the fire place if children elderly or disabled people are present in the same room as the fireplace If regu larly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appl...

Страница 11: ...from out side of the flue material EN 1856 1 T600 N1 D Vm L20040 O 50 Outlets fig 1 4 The balanced flue pipe for combined air supply and discharge can use a wall terminal or a roof termi nal Verify that the desired outlet meets the local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roo...

Страница 12: ...rovide a flexible gas connection with at least 0 5m extra length so that the control unit can be removed for installa tion and service 4 5 Positioning the fireplace Take into account the installation requirements see chapter 3 Place the fireplace at the right place and level it Rough height adjustment With the adjustable optional legs Accurate height adjustment With the adjustable feet Hanging on ...

Страница 13: ...trol block and its electronics and also limits the temperature of the convection air Use the optional Faber ventilation grids article num ber A9296400 or a similar alternative with a mini mum free passage of 200cm per grid in the space above the fire when building the false chimney Within the false chimney an horizontal screen plate made of non combustible material must be installed just above the...

Страница 14: ... removable once the fire is used 5 2 Side glass For cleaning only it s not necessary to remove the side glass MatriX II H and III H First disassemble the front glass section 5 1 Disassemble the glass strip at the top fig 3 6 and 3 7 Place a suction cup and disassemble the side glass fig 3 8 For replacing the glass repeat the steps in reverse order Please note Avoid fingerprints on the glass these ...

Страница 15: ...the ignition and ionization pin do not make contact with ash material or a wooden log 2 The glow effect on the wooden logs That all wooden logs have the right position That the light guides are not co vered by ash material 3 That no glow effect is visible at the back wall 4 On an even ash bed glow Attention Start the fire for the first time without the glass installed Start the fire as described i...

Страница 16: ...red at the highest point If the ratio is greater than 1 100 or flue gases are measured in the air supply check the points in section 7 1 8 Instructions for client Recommend that the fire should be checked annually by a qualified specialist to ensure the safe use and to guarantee a long service life Provide instructions on the operation of o the appliance o the remote control o if present the App a...

Страница 17: ...otal Horizontal Length THL THL is the Total Horizontal Length and consists of elbows and pipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the ele ments H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are elbows entirely in the horizontal plane fig ...

Страница 18: ... x x x 3 30 2 x x x x 4 40 2 x x x x 5 40 2 x x x x 6 40 2 x x x x 7 50 2 x x x x 8 50 2 x x x x 9 50 2 x x x x 10 60 2 x x x x 11 60 2 x x x x 12 60 2 x x x x 13 70 2 x x x x 14 70 2 x x x x 15 70 2 x x x x 16 70 2 x x x x 17 70 2 x x x x 18 80 2 x x x x 19 80 2 x x x x 20 80 2 x x x x 21 80 2 x x x x 22 80 2 x x x x 23 80 2 x x x x 24 80 2 x x x x 25 80 2 x x x x 26 80 2 x x x x 27 80 2 x x x x ...

Страница 19: ...Installation manual MatriX 800 500 650 I II III H 18 11 2 Restrictor table 130 200 MatriX 800 500 I II III H and 800 650 I II III H Start length STL Vertical TVH and Horizontal THL ...

Страница 20: ...Installation manual MatriX 800 500 650 I II III H 19 12 Examples flue material ...

Страница 21: ...izontal direction x 1 5 45 Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Value Start length STL First part on top of the appliance Flue length from 0 1m till 0 45m Flue length from 0 5m till 0 90m Flue length from 1m till 1 4m Flue length from 1 5m till 2m Flue length 2m or more Bend 90 Bend 45 30 or 15 Roof terminal Wall terminal Calculation Total Rounded value Tot...

Страница 22: ...tall from the fire first an adjuster to 130 200 and 1 meter 130 200 after that reduce to 100 150 again and continue with 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and THL and enter the value that is found If the detected value is a number check whether the completed STL is higher or equal to the value in the table Is the STL...

Страница 23: ...iency class B B Energy efficiency index EEI 87 87 Type heating output control room temperature no no no no no yes Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection yes With electronic control of the room temperature With electronic control of the room temperature plus day t...

Страница 24: ...s B B Energy efficiency index EEI 88 87 Type heating output control room temperature no no no no no yes Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection yes With electronic control of the room temperature With electronic control of the room temperature plus day time switch...

Страница 25: ...ion Position outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000...

Страница 26: ...Installation manual MatriX 800 500 650 I II III H 25 16 Top view sectional burner 800 I II III H 16 1 Position led spots and burners 16 2 Position light guides ...

Страница 27: ...Installation manual MatriX 800 500 650 I II III H 26 17 Log set lay out MatriX 800 I II III H Use the included decoration instruction card or for a clear instruction video scan the QR code ...

Страница 28: ...Installation manual MatriX 800 500 650 I II III H 27 18 Dimensional drawings 18 1 MatriX 800 500 I H ...

Страница 29: ...Installation manual MatriX 800 500 650 I II III H 28 18 2 MatriX 800 500 IIL H ...

Страница 30: ...Installation manual MatriX 800 500 650 I II III H 29 18 3 MatriX 800 500 IIR H ...

Страница 31: ...Installation manual MatriX 800 500 650 I II III H 30 18 4 MatriX 800 500 III H ...

Страница 32: ...Installation manual MatriX 800 500 650 I II III H 31 18 5 MatriX 800 650 I H ...

Страница 33: ...Installation manual MatriX 800 500 650 I II III H 32 18 6 MatriX 800 650 IIL H ...

Страница 34: ...Installation manual MatriX 800 500 650 I II III H 33 18 7 MatriX 800 650 IIR H ...

Страница 35: ...Installation manual MatriX 800 500 650 I II III H 34 18 8 MatriX 800 650 III H ...

Страница 36: ...Installation manual MatriX 800 500 650 I II III H 35 18 9 Wall bracket MatriX 800 500 I II III H and MatriX 800 650 I II III H article number A9325896 ...

Страница 37: ...Installation manual MatriX 800 500 650 I II III H 36 18 10 Control box FAB1806 ...

Страница 38: ...Installation manual MatriX 800 500 650 I II III H 37 18 11 Ventilation grid article number A9296400 ...

Страница 39: ...Installation manual MatriX 800 500 650 I II III H 38 18 12 Adjustable feet article number A9319696 ...

Страница 40: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...