6 <
<
<
<
L
Clear a safe space to store the frame and the glass.
Remove the frame, (if necessary) and the glass and take the separately wrapped
parts out of the appliance.
Prepare the gas connection to the gas control valve.
4.4
Placing the appliance
Take the installation requirements into account (see chapter 3).
Place the appliance into the proper position and if necessary,
There is no possibility to adjust the height of the fire.
4.5
Mounting the smoke emission outlet materials
In case of a wall or roof terminal, the hole must be at least 5mm bigger than the
diameter of the flue material.
Horizontal parts must be installed at a (3 degree) slope up away the appliance.
Build up the system from the appliance. If this is not possible, you should make use
of an adjustable pipe.
For fitting the system a ½ metre cut-down pipe should be used. Make sure the
inner pipe is always 2cm longer than the outer pipe. Wall and roof terminal are also
shortened. These parts must be secured with a self-tapping screw.
Do not insulate but ventilate build-in flue material (approx. 100cm2).
4.6
Building a false chimney breast
Before constructing the chimney breast we advise you to perform a function test with the
appliance as described in chapter 7 “checking the installation”.
Construct the false chimney breast from non-combustible material in combination
with metal profiles or of brickwork / aerated concrete bricks.
Take the grills into account. (See fig. 1.1 and 1.2). Place a protective shield made
of non-inflammable material above the grills (see fig. 1.1 A).
Always use a lintel if the chimney breast is constructed of brickwork. These should
not be placed directly onto the appliance.
Construct the chimney breast against the build-in frame (see fig. 1.1 B).
Keep a minimum margin of 3mm between chimney breast and the appliance in
connection with the expansion of the appliance.
The depth of the recess into the chimney breast has no influence on the removal of
the glass.
Содержание Fyn 450
Страница 1: ...Fyn 450 40010929 1840 Fyn 450 ENG ...
Страница 2: ...1 L 1 1 1 2 1 3 1 4 1 5 1 6 2 1 2 2 2 3 ...
Страница 3: ...2 L 3 1 3 2 4 0 4 1 4 2 4 3 4 4 ...
Страница 15: ...14 L 12 Examples flue materials Fig 12 1 Fig 12 2 Fig 12 3 ...
Страница 21: ...20 L 16Troubleshooting guide ...
Страница 22: ...21 L YES ...
Страница 23: ...22 L YES YES ...
Страница 24: ...23 L ...
Страница 25: ...24 L ...
Страница 26: ...25 L 17Dimensional drawings 17 1 Fyn 450 ...
Страница 27: ...26 L 17 2 Ventilation grid ...
Страница 28: ...27 L 17 3 Remote access door ...
Страница 29: ...28 L ...
Страница 30: ...29 L ...
Страница 31: ...Fyn 450 ...