FABER CONSUMER WARRANTY & SERVICE  

All Faber products are warranted against any defect in materials or workmanship for the original purchaser 

for a period of 1 year from the date of original purchase (requires proof of purchase).  This warranty covers 

labor and replacement parts.  Faber, at its option, may repair or replace the product or components 

necessary to restore the product to good working condition.  To obtain warranty service, contact the dealer 

from whom you purchased the range hood, or the local Faber distributor. If you cannot identify a local Faber 

distributor, contact us at (508) 358-5353 for the name of a distributor in your area. 

The following is not covered by Faber's warranty: 

1. Service calls to correct the installation of your range hood, to instruct you how to use your range hood, to 

replace or repair house fuses or to correct house wiring or plumbing. 

2. Service calls to repair or replace range hood light bulbs, fuses or filters. Those consumable parts are 

excluded from warranty coverage. 

3. Repairs when your range hood is used for other than normal, single-family household use. 

4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, 

installation not in accordance with electrical or plumbing codes or Faber documentation, or use of products 

not approved by Faber. 

5. Replacement parts or repair labor costs for units operated outside the United States or Canada, including 

any non-UL or C-UL approved Faber range hoods. 

6. Repairs to the hood resulting from unauthorized modifications made to the range hood. 

7. Expenses for travel and transportation for product service in remote locations and pickup and delivery 

charges. Faber range hoods should be serviced in the home. 

THIS WARRANTY DOES NOT ALLOW RECOVERY OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT 

LIMITATION, DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, PERSONAL INJURY/WRONGFUL 

DEATH OR LOST PROFITS FABER  WARRANTY IS LIMITED TO THE ABOVE CONDITIONS AND TO THE WARRANTY PERIOD 

SPECIFIED HEREIN AND IS EXCLUSIVE. EXCEPT AS EXPRESSLY SPECIFIED IN THIS AGREEMENT, FABER DISCLAIMS ALL 

EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS, AND WARRANTIES INCLUDING, WITHOUT LIMITATION, ANY 

IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

This warranty gives you specific legal rights that may vary from state to state. 

Model#: ______________________________                  Serial #: _____________________________ 

Содержание CLAS30SS600-B

Страница 1: ...CLAS30SS600 B CLAS36SS600 B CLAS30SS300 B CLAS36SS300 B Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien CLASSICA PLUS...

Страница 2: ...XNTQ A BJ SN M DWHS Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO RED...

Страница 3: ...to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to where the vent sys...

Страница 4: ...e for grounding DO NOT ground to a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock q GDBJ VHSG PT KHjDC DKDB...

Страница 5: ...5 RANGEHOOD DIMENSIONS Min 24...

Страница 6: ...b 6 Screws 1 8 x 3 8 Qty Documentation 1 Instruction Manual 1 2 2 2 1 10 7 2 1 12b Available Accessories Direct Connect Wiring Box sku number WIREBOX Activated Charcoal Filter sku FILTER1 LJK HLOLQJ K...

Страница 7: ...culation Option Ducted Venting Options Installation Requires purchase of Activated Charcoal Accessory Horizontal Vertical 6 H I Install Damper that is included with the Hood before connecting to the d...

Страница 8: ...e the cooking surface 3ODFH D EUDFNHW RQ WKH ZDOO DV VKRZQ DERXW 1 8 from the ceiling or upper limit aligning the centers notch with the vertical reference line and mark the wall at the centers of the...

Страница 9: ...d with wall plugs purchase separately Insert not completely the two screws 12a VXSSOLHG LQ WKH KRRG ERG LQJ KROHV DV shown Hook the hood body onto the screws and screw completely From inside the Hood...

Страница 10: ...t er purchased separately onto the hood body air outlet 12 Fix the bracket 7 2 1 using the screws 12a supplied 11 Slightly widen the two sides of the lower section and hook them between the upper sect...

Страница 11: ...JURXQGLQJ LQVWUXFWLRQV are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord LV WRR VKRUW KDYH D TXDO...

Страница 12: ...WLPHG WR UXQ IRU PLQXWHV W WKH HQG RI WKLV WLPH LW ZLOO DXWRPDWLFDOO UHWXUQ WR WKH VSHHG VHW EHIRUH 6XLWDEOH WR GHDO with maximum levels of cooking fumes If you hold this button down for 2 seconds wh...

Страница 13: ...the surface of WKH OWHU FKDQJHV FRORU RYHU WLPH WKLV ZLOO KDYH DEVROXWHO QR HIIHFW RQ LWV HI FLHQF Replace taking care to ensure that the handle faces forward OHDQLQJ LQ GLVKZDVKHU PD GXOO WKH QLVK R...

Страница 14: ...14 Wiring Diagram 991 0379 495 H90_285 r1...

Страница 15: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Страница 16: ...MD UNHD CD RNQSHD RD SQNTUD CDQQH QD UNTR ODMC MS PTD UNTR SDHFMDY KDR l LLDR e OQ R KD FTHCD g HSBGDM HQDR EDSX 3HOR u OTAKH O Q K TW S SR 4MHR AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LEC...

Страница 17: ...EQNHC HMUDQRD HMRH PTeTMD A QQH QD SGDQLHPTD MNM L S KKHPTD ONTQ Q CTHQD K BNMCTBSHNM CDR SDLO Q STQDR DWS QHDTQDR D QDFHRSQD CNHS SQD HMRS KK CT B S HQ EQNHC O Q Q OONQS K A QQH QD SGDQLHPTD A QQH QD...

Страница 18: ...TW q e43 2 9 2 TMD BNMCTHSD CD F Y ONTQ K LHRD K SDQQD q e 23 9 2 TM ETRHAKD RTQ KD BHQBTHS MDTSQD NT KD BHQBTHS CD LHRD K SDQQD OQ RDMBD CeTM ETRHAKD C MR KD BHQBTHS MDTSQD NT CD LHRD K SDQQD ODTS D...

Страница 19: ...19 Min 24 DIMENSIONS DE LA HOTTE...

Страница 20: ...1 Moded emploi 1 2 2 2 1 10 7 2 1 12b Accessoires disponibles RvWLHU GH FRQQH LRQ GLUHFWH QR G DUWLFOH 5 2 1R G DUWLFOH LOWUH j FKDUERQ DFWLI FILTER1 Trousse de chemin e pour plafonds hauts Conduit de...

Страница 21: ...der aux conduits Pour installation avec ventilation canalis e uniquement Choisissez la m thode de canalisation Sans canalisation Option de recirculation Options d installation avec ventilation canalis...

Страница 22: ...DU UDSSRUW j OD VXUIDFH GH FXLVVRQ 3ODFH XQH EULGH VXU OH PXU FRPPH LOOXVWUp j HQYLURQ 1 8 du plafond ou de la limite sup rieure en alignant les centres encoche avec la ligne de r f rence YHUWLFDOH 0D...

Страница 23: ...t Ins rez partiellement les deux vis 12a IRXUQLHV GDQV OHV WURXV GH DWLRQ GX EkWL de la hotte comme illustr QJDJH OH EkWL GH OD KRWWH VXU OHV YLV HW YLVVH OHV FRPSOqWHPHQW O LQWpULHXU GX EkWL GH OD KR...

Страница 24: ...puis raccordez les conduits Installation avec canalisation verticale ou horizontale Option non canalis e avec recirculation d air cartez l g rement les deux c t s de la chemin e sup ri eure et engage...

Страница 25: ...GHV GRXWHV TXDQW j OD PLVH j OD WHUUH GH O DSSDUHLO 1 XWLOLVH SDV GH UDOORQJH 6L OH FRUGRQ G DOLPHQWDWLRQ HVW WURS FRXUW GHPDQGH j XQ pOHFWULFLHQ TXDOL p G LQVWDOOHU XQH SULVH j SUR LPLWp GH O DSSDUH...

Страница 26: ...7 66 17 16 9 SRXU XQH GXUpH GH PLQXWHV SUqV FH GpODL OD YLWHVVH UHWRXUQHUD DXWRPDWLTXHPHQW j la vitesse s lectionn e pr c demment Utile pour contrer les manations maximales de cuisson 6L YRXV WHQH FH...

Страница 27: ...OHXU j OD VXUIDFH GX OWUH DX O GX WHPSV Q D DXFXQ LPSDFW VXU VRQ HI FDFLWp Remettez leenplace envousassurantque OD SRLJQpH VH WURXYH YHUV O DYDQW H ODYH YDLVVHOOH SRXUUDLW WHUQLU OH QL GX OWUH j JUDLV...

Страница 28: ...28 991 0379 495 H90_285 r1 Sch ma de c blage...

Страница 29: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...B B...