I n s t a l l a t i o n   I n s t r u c t i o n s

6

7.3  

Checking the burner pressure and primary  

 

  pressure

Check that the burner pressure and primary pressure match the 

information listed in the manual, Chapter 14 Technical specificati-

ons. 

Measuring the primary pressure:

• 

Close the shutoff valve.

• 

Turn measuring nipple D (Fig. 1.7) some turns open and    

 

connect a measuring hose to the gas regulator.

• 

Take this measurement at highest setting of the fire and when  

 

the fire is set to pilot light.

• 

Do not connect the unit if the pressure is too high.

Measuring the burner pressure:

 

Check the burner pressure only with proper primary pressure. 

• 

Turn measuring nipple E (Fig. 1.7) some turns open and    

 

connect a measuring hose to the gas regulator.

• 

The pressure must correspond to the value indicated in the   

 

technical specifications of this manual. In case of deviation   

 

contact the manufacturer.

 

> Please note: Close all pressure measuring nipples and  

 

check for gas leakage.

7.4  

Checking the flame image

Let the fire burn for at least 20 minutes at highest setting and check 

the flame for:

1.  Flame distribution

2.  Colour of the flames

If one or both points are not acceptable then check:

• 

The log set layout and/or the amount of chips on the burner.

• 

The pipe connections for leaks (in case of blue flames).

• 

Whether the correct Restrictor is fitted.

• 

The outlet. 

 

Wall terminal right side up

 

Roof terminal on the right position

 

If the maximum horizontal flue lengths is not exceeded.

8 Instructions for client

• 

Recommend that the unit should be checked annually by a   

 

qualified specialist to ensure the safe use and to guarantee a  

 

long service life.

• 

Give advice and instructions on care and cleaning of the    

 

glass. Highlight the danger of burnt-in fingerprints.

• 

Instruct the customer on the operation of the unit and the    

 

remote control, setting the receiver.

• 

Handover to customer:

 

Installation instructions 

 

User manual 

 

Log set instruction card 

9 Annual maintenance

9.1  

Checking and cleaning:

• 

Check and clean if necessary after verification:

 

The pilot light 

 

The burners

 

The combustion chamber

 

The glass 

 

The ceramic logs for breakages.

 

The flue system. 

• 

Replace, if necessary:

 

Chips/vermiculite

 

Glass fragments

9.2  

Cleaning the glass

Most deposits can be removed with a dry cloth. Clean the glass 

with a ceramic hob cleaner. 

 

> Please note: Avoid fingerprints on the glass. These    

 

cannot be removed after they are burnt in!

Now carry out the checks described in Chapter 7 “Checking after 

installation”.

10  Conversion to other gas type

The conversion to a different gas type may only be performed by a 

qualified installer/dealer.

10.1 

Conversion from natural gas to propane 

   

(or vice versa)

This can only be done by replacing the burner. To do so, please 

contact your dealer.

Specify with your order always the type and serial number of the 

device.

Содержание Blokhus 40011609-1545

Страница 1: ...Blokhus 40011609 1545 Blokhus ENG ...

Страница 2: ...I n s t a l l a t i o n I n s t r u c t i o n s 2 DE 1 6 1 4 1 7 1 5 1 1 1 3 1 2 A C B ...

Страница 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 A B C AUX 2 0 1 8 1 9 2 1 2 2 F ...

Страница 4: ...fire moisture and uncured volatile components from paint building materials and carpeted floors etc are attracted These parts can settle as soot on cold surfaces Therefore do not light the fire shortly after installation 3 Installation requirements 3 1 Minimum distances to combustible materials around the fire Keep a minimum distance of 20 millimetres to the back wall and 500 millimetres at the si...

Страница 5: ...ou can make use of an extendable adapter section For truing up the exhaust system use the meter pipe which can be shortened and ensure that the inner pipe is always 2cm longer than the outer pipe Any parts which can be shortened must be secured with a self tapping screw Wall and roof terminals can also be cut to length Do not insulate but ventilate any built in flue pipes approx 100cm2 When using ...

Страница 6: ...rrect Restrictor is fitted The outlet Wall terminal right side up Roof terminal on the right position If the maximum horizontal flue lengths is not exceeded 8 Instructions for client Recommend that the unit should be checked annually by a qualified specialist to ensure the safe use and to guarantee a long service life Give advice and instructions on care and cleaning of the glass Highlight the dan...

Страница 7: ...ch are entirely in the horizontal plane Elbows I K and Q and the elements H J L M P and R Fig 12 2 and 12 3 Horizontal length The horizontal length consists of the elements H J L M P and R Fig 12 2 end 12 3 Elbows 90 in the horizontal plane Horizontal bends are bends which are entirely in the horizontal plane Fig 12 1 12 2 and 12 3 I K and Q Bends 45 or 30 in the horizontal plane Horizontal bends ...

Страница 8: ...0 30 0 x x x x 11 65 60 50 40 30 0 0 x x x x 12 65 60 50 40 30 0 0 x x x x 13 65 60 50 40 30 0 0 x x x x 14 65 60 50 40 30 0 0 x x x x 15 65 60 50 40 30 0 0 x x x x 16 65 60 50 40 30 0 0 x x x x 17 65 60 50 40 30 0 0 x x x x 18 65 60 50 40 30 0 0 x x x x 19 65 60 50 40 30 0 0 x x x x 20 65 60 50 40 30 0 0 x x x x 21 65 60 50 40 30 0 0 x x x x 22 65 60 50 40 30 0 0 x x x x 23 65 60 50 40 30 0 0 x x...

Страница 9: ...I n s t a l l a t i o n I n s t r u c t i o n s 9 12 Examples flue materials fig 12 1 fig 12 2 fig 12 3 ...

Страница 10: ... 45 Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Value Starter length STL First part on top of the appliance Flue length from 0 1m till 0 45m Flue length from 0 5m till 0 90m Flue length from 1m till 1 4m Flue length from 1 5m till 2m Flue length 2m or more Bend 90 Bend 45 30 or 15 Roof terminal Wall terminal Calculation Total rounded value Total Vertical Height TV...

Страница 11: ...ter just before the terminal Wall terminal 130 200 0 4 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and THL and enter the value that is found If the detected value is a number check whether the completed STL is higher or equal to the value in the table Is the STL value lower as specified in the table then the installation is not possible S...

Страница 12: ...d 1013 mbar gr h 500 480 Burner pressure at full mark mbar 10 22 24 5 Injector main burner mm 3x 1 50 3x 0 90 3x 0 90 Reduced input restraint mm 1 6 0 85 0 85 Pilot flame SIT160 SIT160 SIT160 Code pilot flame injector Nr 51 Nr 30 Nr 30 Diameter outlet inlet mm 100 150 100 150 100 150 Gas controle valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 230 230 230 Batteries receiver...

Страница 13: ... two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof terminal Only for existing Chimney connection Extension pipe over roof 1 3 I n s t a l l a t i o n I n s t r u c t i o n s 15 Terminal position Please note These rules apply only for the proper functioning of the unit for ventilation and environmental protection y...

Страница 14: ...ad Cut of a small piece from the sparking plug Tie wraps removed Cable is free from any metal parts 4x 1 5V AA Alkaline Thermocouple circuit is interrupted check 8 wire cable from receiver to the gas valve If the wire on the bottom of the gas valve is not broken or stuck and makes a ground contact Motor gas valve doesn t work Micro switch on gas valve doesn t work 3 short beep s 1 long beep Faulty...

Страница 15: ...lot burner is leaking Gasket between burner unit is leaking Glass seal is leaking Flue parts aren t 100 connected check flue system Replace batteries in the receiver Check the distance from thermocouple to pilot flame Measure the mvolts over the thermocouple required min 4mvolts over black and ground contact Flame stays blue lift from the burner and fire switch of Check flue calculation horizontal...

Страница 16: ...aulty parts RESET the receiver Gas vlave broken poor or loose contact Short circuit in wiring Install a ground cable from the gas valve to the appliance Optional Step burner function can be turned ON and OFF only with remote RESET the receiver Check the wiring from solenoid valve to receiver Faulty solenoid valve Faulty receiver Repaire the wiring Replace solenoid valve Replace receiver ...

Страница 17: ...1 7 I n s t a l l a t i o n I n s t r u c t i o n s 17 Dimensional drawings 17 1 Blokhus 17 2 Position gas connection ...

Страница 18: ...18 Instruction extension Module s 1 8 I n s t a l l a t i o n I n s t r u c t i o n s ...

Страница 19: ...n module s Preparation Remove the module s from its packaging Loosen screws A on the inside Photo 1 to remove the panels If necessary the back panel s can be removed by loosening scews B Photo 1 Remove the upper panel of the fire by loosening screws A Montage Place and screw the first extension module on the fire with the included screws and nuts Photo 2 Install the first flue part on the fire If ...

Страница 20: ...2 0 I n s t a l l a t i o n I n s t r u c t i o n s 20 2 Extension module double 20 Dimensional drawings 20 1 Extension module single ...

Страница 21: ...2 1 I n s t a l l a t i o n I n s t r u c t i o n s 20 3 Wall bracket ...

Страница 22: ...2 2 I n s t a l l a t i o n I n s t r u c t i o n s ...

Страница 23: ...2 3 I n s t a l l a t i o n I n s t r u c t i o n s ...

Страница 24: ...2 4 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo ...

Отзывы: