INSTALL  THE  CANOPY

1. 

Remove  the  unit  from  the  carton  and  place  on  a 

flat  surface  for  assembly.    Cover  the  surface  to  prevent 

accidental damage.  Remove all parts including the mounting 

hardware before discarding the carton.  DO NOT REMOVE 

THE  PROTECTIVE  PLASTIC  UNTIL  INSTALLATION  IS 

COMPLETE.

2. 

For ducted installations, attach the duct adaptor to the 

rear of the blower 

(FIGURE 6A)

.  For ductless installations, 

attach the vent grate to the top of the blower 

(FIGURE 6B)

.  

The cover over the vent opening must be removed before 

installing the vent grate.  The cover should be installed in the 

rear vent opening.

PREPARE  THE  WALL

1. 

Disconnect and move freestanding range from cabinet 

opening to provide easier access to upper cabinet and rear 

wall.  Put a thick, protective covering over cooktop, set-in 

range or countertop to protect from damage or dirt.

2. 

Determine and clearly mark with a pencil the center line 

on the wall where the rangehood will be installed.

3. 

 The Axia attaches to the wall by two mounting screws (

in FIGURE 5)

  and an upper  mounting bracket 

(2 in FIGURE 

5)

.  Since the entire weight of the canopy is supported by the 

two screws, these must be installed into solid material like 

solid wood, brick or concrete.  If these screws are installed 

into sheet rock, then anchoring devices must be used suitable 

for the weight of the rangehood.  The position of the screws 

(1 in

 

FIGURE 5)

 are shown below.  The height of the canopy 

over the cooking surface will determine the position of the 

screws.  Install the two screws into solid material.  These 

screws should be installed into the wall leaving about 1/4" 

between the head of the screw and the wall.

FIGURE  5

6. 

Determine the proper location for the Power Supply 

Cable.  Use a 1  1/4" Drill Bit to make this hole.  Run the 

Power Supply Cable.  Once the rangehood is installed, use 

caulking to seal around the hole.  DO NOT turn on the power 

until installation is complete.

FIGURE 7

4. 

The length of the chimney 

(Z in FIGURE 5)

 is adjustable 

and determines where the upper bracket is installed 

(2 in 

FIGURE 5)

.  The bracket attaches to the wall by one screw 

.  This bracket mounts to the underside of the blower and 

supports the weight of the blower.  Since the entire weight of 

the blower is supported by this bracket, it must be installed 

into solid material like solid wood, brick or concrete.  If this 

bracket is installed into sheet rock, then anchoring devices 

must be used suitable for the weight of the blower.

FIGURE 6B

Version 02/02 - Page 5

3. 

Remove the grease filters from the unit and set aside.  

The grease filters are removed by pressing the handle in front 

of the filter as indicated in 

FIGURE 7

.  When replacing, make 

sure that the filters are properly positioned with the handles 

in front and visible.

FIGURE 6A

4.

  Install the two mounting screws 

(O in FIGURE 8)

 into the 

wall.  Attach the support rod 

(B in FIGURE 9)

 to the canopy 

using the two screws 

(Kin FIGURE 9)

 provided.

FIGURE 9

FIGURE 8

5. 

Determine and make all necessary cuts in the wall for 

the ductwork.  Install the ductwork before the rangehood.  For 

ductless installations, the duct cutout is not necessary.

Attach the upper bracket 

(S)

 to the 

wall using the screw 

(V )

 provided. 

Содержание AXIA

Страница 1: ...y Standards titre 24 CFR Section 3280 anciennement Federal Standard for Mobile Home Construction and Safety Standards titre 24 CFR Section 3280 anciennement Federal Standard for Mobile Home Constructi...

Страница 2: ...NOT use 4 laundry type wall caps Flexible type ductwork is not recommended DO NOT obstruct the ow of combustion and ventilation air Failure to follow venting requirements may result in a re When maki...

Страница 3: ...Suivez les conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifac...

Страница 4: ...Axia which requires the canopy to be mounted 24 above the countertop FIGURE 2 CALCULATE THE DUCTRUN LENGTH The ductrun should not exceed 35 feet if ducted with 6 round ductwork Calculate the length o...

Страница 5: ...of the canopy over the cooking surface will determine the position of the screws Install the two screws into solid material These screws should be installed into the wall leaving about 1 4 between th...

Страница 6: ...the canopy using the four screws provided E in FIGURE 15 Insert the transparent seal provided Q in FIGURE 16 so as to eliminate any play between the two parts of the chimney Tighten the chimney screw...

Страница 7: ...bezel is held in place by two screws Remove the two screws and the bezel Then remove the lamp and replace with a new lamp Once the new lamp is in place reinstall the bezel Version 02 02 Page 7 FIGURE...

Страница 8: ...R L INSTALLATION 2 connecteurs de conduit C ble d alimentation 1 capuchon de mur ou de toit Conduit en m tal DIMENSIONS DE L INSTALLATION La chemin e Axia est r glable en fonction des diff rentes haut...

Страница 9: ...utiliser un m canisme qui peut soutenir le poids du ventilateur 5 D terminer et faire toutes les coupes n cessaires dans le mur pour les conduits Installer les conduits avant la hotte Pour les install...

Страница 10: ...pas faire les connexions lectriques FIGURE 14 3 Fixer la chemin e au corps de la hotte l aide des quatre vis E de la FIGURE 15 fournie avec l appareil Ins rer la garniture transparente Q de la FIGURE...

Страница 11: ...rs de la cuisine Panneau de commandes Le panneau de commandes est situ en haut de la hotte La position et la fonction de chaque bouton sont indiqu es la FIGURE 20 Bouton marche arr t de la lumi re L I...

Отзывы: