![FAAC E124 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/faac/e124/e124_original-instructions-manual_3115894034.webp)
2 2
E124 32
532365 - Rev.A
1
2 x Pb 12 V - 4 Ah
90 x 70 x 108 mm
2
3
BATTERY
POWER
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
red (
+
)
black (–)
7.9 EMERGENCY BATTERIES
Use rechargeable lead batteries that can supply:
Volt-
age 20…28 V
"
,
Current 16 A max
.
To install, use the
BATTERY SUPPORT KIT
(see FAAC cata-
logue - includes the connection cables).
1. Remove the cover and set up the enclosure:
G
To prevent the risk of explosion due to the build up of
gas generated by lead batteries, drill a
∅
1 mm hole
in the enclosure. The hole must be at the top of the
battery compartment and must not allow water to get
into the enclosure.
2. Insert the support and rest the batteries on it.
3. Connect the cables supplied to the battery termi-
nals, following the polarity shown.
4. Make sure that the main power connector (POWER)
is already plugged in, then connect the batteries to
the BATTERY connector.
-
The battery operation signal can be enabled, in
programming, on a programmable output (OUT1,
OUT2).
-
Check the BATTERY LED (§ Diagnostics).
5. Replace the cover of the enclosure.
Simply Connect
also allows you to program:
- which movement is carried out before going into SLEEP mode
(last movement OPEN OR CLOSE)
- when the last movement is carried out (IMMEDIATELY or when
the threshold value is reached).
7.10 EXTERNAL POWER SUPPLY
As an alternative to the 230 V mains power supply, an
external stabilized power supply, which can supply
the following power, can be connected to the BAT-
TERY
connector
:
Voltage 20…28 V
"
, Current 16 A max
L
Use programming via Simply Connect to disable the
battery charging function (only with Simply Connect)
Содержание E124
Страница 1: ...E124 Translation of the original instructions...
Страница 43: ......