E045S
18
532373 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
i
The transmitter and receiver of a pair of photocells
must have the same DIP switch settings.
There must never be two or more pairs of photocells
with the same DIP switch settings. If there is more
than one pair of photocells with the same address, a
conflict error is generated.
2. Register the BUS 2easy photocells (see specific
section).
3. Check the BUS 2easy devices (see specific section)
and make sure that the automation operates ac-
cording to the type of photocell installed.
5
Assigning an address to the Photocells
Key: 0=OFF , 1=ON
1 0 0 0
FSW CL
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 1 0
0 0 0 0
FSW OP
0 0 0 1
0 0 1 0
0 0 1 1
0 1 1 1
0 1 0 0
FSW OP/CL
0 1 0 1
1 1 1 1
OPEN
BUS 2EASY SENSITIVE EDGES
!
If the sensitive edge is used to protect against a
hazard, it must comply with standard EN 12978.
Type of use:
CL EDGE Sensitive edge active during closing
OP EDGE Sensitive edge active during opening
The activation of a sensitive edge causes the direction
of movement to reverse, which can be:
-
complete if
iP
=
no
in programming
-
partial (2 s) if
iP
=
Y
in programming
1. Assign an address to the device electronics by
setting the four DIP switches.
i
No two devices should have the same DIP switch set-
tings. If there is more than one device with the same
address, a conflict error is generated.
ON
1 2 3 4
2. Register the device (see specific section).
3. Check the BUS 2easy devices (see specific section)
and make sure that the sensitive edges are working
correctly. When the gate is moving, activate the
sensitive edge using an obstacle and make sure
that the automation operates according to the
type of sensitive edge installed.
6
Addressing Sensitive Edges
Key: 0=OFF , 1=ON
1 1 0 1
CL EDGE
0 1 1 0
OP EDGE
BUS 2EASY ENCODER
1. Connect the cables of the encoder to the 2EASY
terminal board (
2. After turning on power to the board, check the
LEDs on each encoder with the leaf stationary:
DL1
lit = encoder powered
DL2
lit = encoder connected to
MOTOR1
DL2
off = encoder connected to
MOTOR2
i
For each encoder that does not appear to be con-
nected to the correct leaf, temporarily disconnect
the power supply and invert the 2 wires on the 2EASY
terminal board.
3. Register the devices (see specific section).
4. Check the BUS 2easy devices(see specific section).
ON
1 2 3 4