61
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Programmable input 2
No.
Name
Range
Factory Setting Ref. page
P200
Channels in programmable input 2
0 - 1
1
0
Disabled
1
Enabled
P260
Control function
0-5
2
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
P261
Type of control signal when activated
1 - 2
1
1
Pulse (hold-to-run mode not possible)
2
Signal for as long as the input is activated
P262
Half operation
1 - 3
3
1
Half 1
2
Half 2
3
Halves 1 and 2
P263
Limited opening
0 - 1
0
0
Disabled
1
Timed opening based on the time specified in C412 and/or C414
P270
Motor lock
0 - 1
0
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 2. If the signal disappears the
barrier is stopped.
P280
Park
0 - 2
2
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal
P290
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P260 is set to open, and passes the signal on to the remote door
P296
Blocking disabled for local and remote doors. Only
works if there is a constant signal and P261 has the
value 2.
0 - 1
0
0
Disabled
1
Active
P298
Automatic closing disabled for remote door Only
works if there is a constant signal
0 - 1
0
0
Disabled
1
Active