16
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Configuring the EP104
This section provides general instructions on how to change settings in the EP104.
It is a good idea to discharge any static charge in your body by always touching an earthed connection before starting installation.
• General
All values are stored according to a list of channels (in the channel reference), with each channel corresponding to a particular
control parameter or value in the EP104.
The display can show a value up to four digits long, or a channel number with the prefix C, d, L, o, P or r, followed by three
digits.
The display can be used to show values as well as change settings – the value flashes while the setting is being changed.
If E appears followed by a number, this is an error message – see "Error messages". Note that the start-up values "EP-1" and
"EP-2" are not error messages. When the power is connected, EP-1 appears when the unit controls one motor, and EP-2 when
the unit controls two motors.
The <
┘
button switches between the value and the channel number, or in configuration mode, it saves the value.
The + button scrolls up the channel list in channel mode. In configuration mode, the button increases the value.
The - button scrolls down the channel list in channel mode. In configuration mode, the button reduces the value.
If no button is pressed in 90 seconds, the display switches to economy mode with reduced brightness. Press any button to
return to normal mode.
Display
Description
Cnnn
Channel number for the EP104
dnnn
Channel number for the vehicle
detector
Lnnn
Channel number for the limit switch
onnn
Channel number for the output card
Pnnn
Channel number for programmable
inputs
rnnn
Channel number for the wireless card
Ennn
Error message (not EP-1 and EP-2)
nnnn
Readout of value
nnnn (flashing)
Value being changed
Button
Description
+
Button to increase the channel or value
-
Button to decrease the channel or value
<
┘
Switch between channel number and
value
<
┘
Save/confirm the changed value
Switch between different channel
groups
• Readout of parameters in the EP104
Press the <
┘
button so the display shows the channel number – a letter followed by digits.
Press the button to quickly change between letters (channel groups).
Press the + or - button to step to the channel number you want.
Press the <
┘
to show the value on the display.
Press the <
┘
button again to exit and return to the channel number. Leave the unit in this mode – you cannot exit any further.
• Setting parameters in the EP104
Select the channel number according to the readout above.
Press the + button. The value starts flashing and is ready to be changed.
Press the + or - button to step to the value you want.
Press the <
┘
button to save the value.
Press the <
┘
button again to exit and return to the channel number. Leave the unit in this mode – you cannot exit any further.
• Locked settings
Settings may be locked by service personnel so they cannot be changed. Contact an authorised service engineer, who will have
the instructions needed to release the unit for configuration.
Содержание DAAB EP104