![FAAC DAAB EP104 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053010.webp)
10
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Technical specification
Dimensions (WxHxD)
190x224x60 mm.
Power supply
3-phase or single-phase.
Power supply
N+PE, PE, N+PE, PE (requires external transformer)
Permitted voltage variation
±10%
Frequency
50 Hz.
Motor in 3-phase operation
3x400 V
3-phase asynchronous motor 0.18-1.5 kW.
Motor in 3-phase operation
3x230 V
3-phase asynchronous motor 0.18-0.75 kW.
Motor in single-phase
operation
Single-phase motor with capacitor 0.18-0.37 kW.
Fuses
External fuse max T10A.
Power consumption
Automatic control unit 22 VA + electric motors.
Operating mode
Intermittent operation 50% / maximum period of use 4 minutes
Temperature range
0 to 45 °C.
Safety edge
2 closing inputs S.E1 and S.E2 for safety edge while closing.
1 opening input S.E3 for safety edge in the opening movement.
Impedance 1.0-8.2 kΩ, power capability at least ½ W.
Safety circuit
Max impedance 3 Ω in stop circuit.
Cable length 0.75mm2 max 60m. Cable length 1.5mm2 max 120m.
One 0-50 V analogue input to measure the voltage after the stop circuit.
Internal motor protection
Setting range 0.5-6 A.
Load guard
Setting range 0.05-1.99 kW.
Digital inputs
9
Logical 0 0-8VDC.
Logical 1 12-30VDC.
Input current 5mA at 24VDC.
Cable length max 200m
Supply voltage for photocell 24VDC max 50mA.
External supply
24VDC max 300mA.
Communication
RS-485 between two EP104 units. Cable length max 1000m.
Protection class
The PCB is designed for an enclosure rating of at least IP54.
Содержание DAAB EP104