INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402
Revision 7
9
Channel list, d-channels
Vehicle loop 1
Note that the display of the d-channels is determined by the setting in C702 for EP105
No.
Name
Range
Factory Setting
d100
Vehicle loop 1
0 – 1
0
0
Disabled
1
Enabled
d101
Loop reading x1
000 - 999
d102
Loop reading x1000
00 - 99
d103
Activation by passing vehicle
000 - 999
d110
Detection limit for a vehicle in the loop
05 - 99
15
d111
Difference between on and off in the loop
00 - 50
03
d120
Loop presence reset
000 and 005-240
minutes
120
d121
Fast loop presence reset
00-99 seconds
00
d131
Compensation for activation from door half motor 1 on the
loop in the closed position
00 - 50
03
d132
Compensation for activation from door half motor 2 on the
loop in the closed position
00 - 50
03
d140
Safety function in closing movement
0 - 4
1
0
Disabled
1
Reverse
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
4
Safety only in open position. Used when the gate passes over the loop in the closing movement.
d141
Safety during run-on time or disengagement angle in closing
movement.
0 – 1
1
0
Disabled
1
Activated according to d140
d142
Safety function in opening movement
0 - 4
0
0
Disabled
1
Reverse to fully closed
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
4
Safety only in closed position. Used when the gate passes over the loop in the opening movement.
d151
Loop-based closing
0 - 1
0
0
Disabled
1
Active
d154
Type of closing
1 - 2
2
1
Close immediately when loop is clear
2
Continue to fully open, then close
Содержание DAAB DB402
Страница 13: ...INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 Revision 7 13 Notes...
Страница 14: ......