INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402
Revision 7
11
Vehicle loop 2
Note that the display of the d-channels is determined by the setting in C702 for EP105
No.
Name
Range
Factory Setting
d200
Vehicle loop 2
0 - 1
0
0
Disabled
1
Enabled
d201
Loop reading x1
000 - 999
d202
Loop reading x1000
00 - 99
d203
Activation from passing vehicle
000 - 999
d210
Detection limit for a vehicle in the loop
05 - 99
15
d211
Difference between on and off in the loop
00 - 50
03
d220
Loop presence reset
000 and 005-240
minutes
120
d221
Fast loop presence reset
00-99 seconds
00
d231
Compensation for activation from door half motor 1 on the
loop in the closed position
00 - 50
03
d232
Compensation for activation from door half motor 2 on the
loop in the closed position
00 - 50
03
d240
Safety function in closing movement
0 - 4
1
0
Disabled
1
Reverse
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
4
Safety only in open position. Used when the gate passes over the loop in the closing movement.
d241
Safety during run-on time or disengagement angle in closing
movement.
0 - 1
1
0
Disabled
1
Activated according to d240
d242
Safety function in opening movement
0 - 4
0
0
Disabled
1
Reverse to fully closed
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
4
Safety only in closed position. Used when the gate passes over the loop in the opening movement.
d251
Loop closing
0 - 1
0
0
Disabled
1
Enabled
d254
Type of closing with loop
1 - 2
2
1
Close immediately when loop is clear
2
Open fully first, then close