1.
Remove the existing supply, if one is installed.
2.
Slide the new DC power supply into the empty power supply bay.
3.
Lower the power supply eject lever to fully seat the power supply in its bay.
4.
Secure the power supply by tightening the captive screw on the power supply eject lever.
Note: The screw that holds the ejector handle in place is captive and cannot be removed from the
assembly.
Wiring the DC connector
You will need these components to wire the DC power supply:
•
Wire stripping tool
•
Two 6 AWG copper wires long enough to reach from the platform to the DC power source
The DC power supply for the VIPRION
®
2400 platform includes the components needed to assemble the
DC connector: a DC lock assembly and a DC plug.
Figure 14: VIPRION 2400 DC power supply, lock assembly, and plug
1.
Use the wire stripping tool to remove 3/8 inch (9.56 mm) of insulation from the end of each 6 AWG
wire.