Note: Do not attempt to duplicate the configuration by saving and restoring a user configuration set
(UCS) file from one machine to the other, or any other cloning approach. There are several IDs that
must be unique that will also be duplicated, causing additional problems.
Note: For more detailed information on using the Herculon SSL Orchestrator Setup Wizard, see the
Using the Herculon SSL Orchestrator setup wizard section.
Installing an updated RPM file
Create a backup of your current configuration to ensure your settings are not lost if the update fails.
Having the latest version of F5
®
Herculon
™
SSL Orchestrator
™
establishes the version that later appears
on your other BIG-IP
®
HA peer device. After downloading the latest version of the Herculon SSL
Orchestrator zip file from
, return to your Herculon SSL Orchestrator configuration
utility.
1.
On the Main tab, click
SSL Orchestrator
>
Updates
.
The Updates screen opens.
2.
For the
File Name
setting, click
Browse
and navigate to the file you saved onto your system.
3.
Click
Open
to select it.
4.
Click
Install
.
Note: Install the Herculon SSL Orchestrator configuration utility package (the
*.rpg
file) on the
active system only. That system will copy it to the other systems in the ConfigSync group.
Later, after a successful Herculon SSL Orchestrator HA deployment, you should verify that the same
version appears on the BIG-IP HA peer device. See the section
Updating the Herculon SSL Orchestrator
version
for more detailed installation instructions.
Configuring the network for high availability
You can specify the settings for VLAN HA and self IP addresses on the active device to configure your
network for high availability. If needed, you can configure all devices involved in the high availability
group for HA.
Note: This network connects the various devices and must be a common Layer-2 network between all
devices.
1.
On the Main tab, click
Network
>
VLANs
.
The VLAN List screen opens.
2.
Click
Create
.
A New VLAN screen opens where you can configure your new VLAN.
3.
In the
Name
field, type the name (for example,
ha_vlan
).
4.
For the
Interfaces
setting:
a) From the
Interface
list, select an interface number.
b) From the
Tagging
list, select
Tagged
for traffic for that interface to be tagged with a VLAN ID.
c) Click
Add
.
The interface you selected appears in the
Interfaces
list as a tagged service.
5.
Click
Finished
.
Next to the F5 logo, your device status appears showing
ONLINE (ACTIVE)
and
Standalone
with green indicators showing their status as up and running.
6.
On the Main tab, click
Network
>
Self IPs
.
F5 Herculon SSL Orchestrator: Setup
41
Содержание Herculon SSL Orchestrator
Страница 1: ...F5 Herculon SSL Orchestrator Setup Version 13 1 3 0 ...
Страница 2: ......
Страница 6: ...What is F5 Herculon SSL Orchestrator 6 ...
Страница 26: ...Setting Up a Basic Configuration 26 ...
Страница 38: ...Importing and Exporting Configurations for Deployment 38 ...
Страница 54: ...Using Herculon SSL Orchestrator Analytics 54 ...