background image

1. Align the bracket's keyhole slots with the PEM fasteners on the side of the unit.

2. Slide the bracket toward the back of the unit to lock the bracket into place.

Important:  You must secure the bracket to the unit using four of the #6-32 inch screws provided
with the platform.

3. Repeat steps 1 and 2 for the other bracket.

4. Secure the front-mounting brackets to the rack using four rack manufacturer-provided screws.

The unit must be securely fastened to the rack to provide adequate stability and to prevent the unit from
falling out of the rack.

If the rack you have does not provide adequate support for the unit, you might need a shelf kit. F5 Networks
recommends using a shelf kit created by the rack manufacturer, if available.

About the quick-install rail kit

Use the quick-install rail kit if you want to be able to slide the unit in or out of the rack for maintenance
activities. The kit includes two rails (left and right) and eight #8-32 thumb screws. The rails snap into place
in the rack, and no tools are required to install a platform using this kit. The rails are optimized for installation
into square hole cabinets, but they can be installed in other cabinet styles, such as round hole cabinets, using
the screws provided. The rails are easily converted to mount to either cabinet style.

Figure 3: Quick-install rail kit

For information about installing the platform using the quick-install rail kit, see the instruction guide provided
by the manufacturer, which is included with the kit hardware.

Note:  Before you install this platform, review the environmental guidelines to make sure that you
are installing and using the platform in the appropriate environment.

After installing the platform, secure it to the rack with the rail lock brackets that are provided.

14

Platform Installation

Содержание 2000 Series

Страница 1: ...Setting Up the 2000 4000 Series Platform MAN 0400 01 ...

Страница 2: ......

Страница 3: ...ting kit to use 13 About the front mounting kit 13 Front mounting kit hardware 13 Installing using a front mounting kit 13 About the quick install rail kit 14 Installing the rail lock brackets 15 Connecting the cables and other hardware 16 Configuring a management IP address using the LCD panel 17 Appendix A Environmental Guidelines 19 General environmental guidelines 20 Guidelines for AC powered ...

Страница 4: ...4 Table of Contents ...

Страница 5: ...Browser Referencing Intelligent Compression IPv6 Gateway iApps iControl iHealth iQuery iRules iRules OnDemand iSession IT agility Your way L7 Rate Shaping LC Link Controller Local Traffic Manager LTM Message Security Module MSM Netcelera OneConnect Packet Velocity Protocol Security Module PSM Real Traffic Policy Builder ScaleN SSLAcceleration StrongBox SuperVIP SYN Check TCP Express TDR TMOS Traff...

Страница 6: ...s Operation of this equipment in a residential area is likely to cause harmful interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Any modifications to this device unless expressly approved by the manufacturer can void the user s authority to operate this equipment under part 15 of the FCC rules Canadian Regu...

Страница 7: ...atform The BIG IP 2000 4000 Series platform is a powerful system that is capable of managing traffic for any size of enterprise Topics About the 2000 4000 Series platform Components provided with the platform Peripheral hardware requirements ...

Страница 8: ...ed failover port 5 10 100 1000 interfaces 6 1 10G SFP ports 7 Indicator LEDs 8 LCD display 9 LCD control buttons Figure 1 Front view of the platform The back of the platform includes one power supply by default Optionally you can install a second power supply 1 Power input panel 1 power switch and power receptacle 2 Power input panel 2 power switch and power receptacle 3 Chassis ground lug with co...

Страница 9: ... interface cards that are installed in the platform You can use either 10 100 1000 Ethernet or 10 Gigabit Ethernet switches Network hubs switches or connectors to connect to the platform network interfaces You can use any USB certified CD DVD mass storage device or a USB flash drive for installing upgrades and for system recovery External USB CD DVD drive or USB flash drive Note External CD DVD dr...

Страница 10: ...10 About the 2000 4000 Series Platform ...

Страница 11: ...you can install the unit Topics About general recommendations for rack mounting Unpacking the platform Determining which rack mounting kit to use About the front mounting kit About the quick install rail kit Installing the rail lock brackets Connecting the cables and other hardware Configuring a management IP address using the LCD panel ...

Страница 12: ...y recommends that at least two people perform the installation Important This product is sensitive to electrostatic discharge ESD F5 Networks recommends that you use proper ESD grounding procedures and equipment when you install or maintain the unit Unpacking the platform The platform ships in a custom designed package that protects the product during shipment Due to the weight of the platform the...

Страница 13: ...orm differ depending on the type of rack mount you decide to use or which type of cabinet unit you are installing into single two post cabinet or four post cabinet About the front mounting kit You can use the front mounting kit if you are installing into a two post rack Front mounting kit hardware The front mounting kit includes these hardware parts Hardware Quantity Front mounting brackets 2 Inst...

Страница 14: ... if you want to be able to slide the unit in or out of the rack for maintenance activities The kit includes two rails left and right and eight 8 32 thumb screws The rails snap into place in the rack and no tools are required to install a platform using this kit The rails are optimized for installation into square hole cabinets but they can be installed in other cabinet styles such as round hole ca...

Страница 15: ...unit using the rail lock screws that are included in the kit 2 Secure the rail lock brackets to the rack on each side of the unit using either the two 8 32 pan head Philips screws that are included with the kit or screws provided by the rack manufacturer Use 18 to 20 inch pounds 2 0 to 2 3 Newton meters of torque on these screws 15 Setting Up the 2000 4000 Series Platform ...

Страница 16: ...d CAT5 cable connect the RJ45F to RJ45M rolled serial adapter to the console port and then connect a CAT5 cable to the adapter Figure 4 The RJ45F to RJ45M rolled serial pass through adapter 2 For a redundant system configuration with hard wired failover capacity connect the serial failover cable to the failover port on each unit 3 For AC powered systems connect the power cable to the power input p...

Страница 17: ... 3 Press the Check button to select Management 4 Press the Check button to select Address Type and then press the Check button again to select either IPv4 or IPv6 5 Use the arrow keys to select Mgmt IP and press the Check button 6 Use the arrow keys to configure the management IP address 7 Use the arrow keys to select Prefix Length and press the Check button 8 Use the arrow keys to configure the l...

Страница 18: ...18 Platform Installation ...

Страница 19: ...Appendix A Environmental Guidelines Topics General environmental guidelines Guidelines for AC powered equipment Guidelines for DC powered equipment ...

Страница 20: ...he air temperature in the room to exceed 104 F 40 C Do not plug the unit into a branch circuit shared by more electronic equipment than the circuit is designed to manage safely at one time Important This product is sensitive to electrostatic discharge ESD F5 Networks recommends that you use proper ESD grounding procedures and equipment when you install or maintain the unit Caution Customers should...

Страница 21: ...lled in a RESTRICTED ACCESS LOCATION such as a central office or customer premises environment Note The following guidelines apply to STATIONARY PLUGGABLE EQUIPMENT TYPE A with simultaneous multiple connections to the AC MAINS SUPPLY The building installation shall provide a means for connection to protective earth and The equipment is to be connected to that means and A SERVICE PERSON shall check...

Страница 22: ... branch circuit protection device to install the unit For permanently connected equipment incorporate a readily accessible disconnect in the fixed wiring Use only copper conductors Cabling for the system must be grounded on both sides Use one power feed for each individual power supply 22 Environmental Guidelines ...

Страница 23: ...ning any equipment contact F5 Networks to obtain a Return Material Authorization RMA case number Important You must use shipping materials and packaging provided by F5 Networks when repackaging the platform Note Be sure that you keep a record of the tracking number and ship date These will be needed to track lost shipments Note Do not include any cables removable XFP SFP modules GBICs or other per...

Страница 24: ...d other cables from the platform and then remove any optical modules 2 Remove the platform from the rack 3 Place the platform in the plastic bag if available 4 Place the foam inserts on the front and back sides of the platform 5 Place the platform into the shipping box 6 Place the accessory boxes in the foam inserts 24 Repackaging Guidelines ...

Страница 25: ...7 Close and seal the shipping box 25 Setting Up the 2000 4000 Series Platform ...

Страница 26: ...26 Repackaging Guidelines ...

Страница 27: ...ment interface 16 management IP address configuring using LCD panel 17 N NEBS air temperature 20 P pass through adapter See RJ45F to RJ45M rolled serial adapter platform about 8 installing 11 repackaging 24 unpacking 12 ventilation 20 platform components 8 power cable 16 Q qkview utility 16 quick install rail kit 14 R rack mount front mount 13 general environmental guidelines 20 quick install rail...

Страница 28: ...terminal hardware installation and 9 16 switches 9 T transporting the platform 23 two post rack 13 U unpacking platform 12 USB port supported CD DVD ROM drives 9 USB thumb drives support for 9 W warnings environmental 20 28 Index ...

Отзывы:

Похожие инструкции для 2000 Series