EZY SWITCH 

LIMITED 

 

SMS-TEMP-2 

System Monitor 

Installation Manual 

 

Содержание SMS-TEMP-2

Страница 1: ...EZY SWITCH LIMITED SMS TEMP 2 System Monitor Installation Manual ...

Страница 2: ...t Tick off 13 Programming the Input reply message 14 Turn an Output ON or OFF 15 Turn an Output ON for a set time 15 Invert Output 15 Make an Output Pulse On and Off 16 Clear Output Pulse Set to non pulsed 16 Turn Output response On Off 17 Save Output Status 17 Set Battery Alarm trigger voltage 17 Link Battery Alarm to Output 18 Check Battery Supply Voltage 18 Latching Non latching battery alarm 1...

Страница 3: ...ally Closed Inputs o Programmable for Normally Open or Normally Closed Outputs Inputs and Outputs names are user programmable via text command up to 20 characters Link any Input to any Output Example Link intruder sensor or smoke detector input to light or alarm horn output Monitors battery supply voltage and sends alarm message if low battery is detected at below the programmed alarm setting On d...

Страница 4: ...MS TEMP 2 Installation Operation Manual SIM Card Supply Voltage Quiescent Current Data Retention Outputs Max Input voltage Temperature Range 12 to 30 Volts DC 800mA 40 Milli amps 10 years without power Relay 3 A resistive 125VAC 30vdc 25 to 80 degrees C SMS TEMP 2 Terminal Electrical Specifications Terminal 1 Batt Terminal 2 Batt Terminal 3 Temperature sensor Terminal 7 Ouput 1 N O Terminal 4 Temp...

Страница 5: ...AC Relay 1 Connection Internal Relay Relay Terminals 7 8 Outputs Ezy Switch SMS TEMP 2 Installation Operation Manual Manual Important Note A registered electrician must be used when connecting to the 120 240v main supply voltage Relay 2 Connection Internal Relay Relay Terminals 9 10 ...

Страница 6: ...input is a 0 to 5vdc input connections shown in Fig 1 Inputs Ezy Switch SMS TEMP 2 Installation Operation Manual Manual SMS TEMP 2 Input 1 Terminal 6 Switch 10 30vdc Fig 2a SMS TEMP 2 Terminal 3 Terminal 4 Temperature sensor Fig 1 SMS TEMP 2 Fig 2b Switch Input1 Terminal 5 Terminal 6 Terminal 3 Sensor GND Terminal 4 Sensor in ...

Страница 7: ...882900 then Command add user 61412882900 Singapore 0065 65 and the number without the preceding 0 If the users number is 0412882900 then Command add user 65412882900 USA Canada 001 1 and the Area Code Number If the users number is 412 555 1234 then Command add user 14125551234 IMPORTANT Ezy Switch SMS TEMP 2 Installation Operation Manual NOTE If a user sends a text message to the system which is n...

Страница 8: ... list Removing a User Command Remove user XXXXXXXX see Country Code page 7 If you try to remove the only master the system responds with Cannot delete the only master if you would like to change masters add the new one before removing the old If the number sent is not currently on the list the system responds with XXXXXXXX is not currently on the masters list so cannot be removed please check the ...

Страница 9: ... the unit using the Master Add command as per above If User lookup is Off the SMS T2 will respond to any number that sends the correct command The system responds with The user lookup list feature has been turned on and the unit will only except commands from programmed users OR The user lookup list feature has been turned off and the unit will only except commands from any users PLEASE NOTE Input...

Страница 10: ...s signal strength is run test now The unit will now test the inputs and outputs and waits for the inputs to be triggered When input1 is turned on output1 will turn on when input1 is turned off output1 will turn off When input2 is turned on output2 will turn on when input2 is turned off output2 will turn off Test finished Get a list of the Inputs Command Input status Currently INPUT NAME is INPUT N...

Страница 11: ... with Sorry either that device does not exist or the message format is not understood please check the spelling and try again If the new name chosen does not fulfill the requirements of a name the system responds with Sorry that name is not allowed please check that it is between 1 and 20 characters long If everything is ok the system responds with The input name has been changed to YYYYYYYYYY Or ...

Страница 12: ... is all ready set for either open or closed and does not need changing Set an Input as a latched Input Command Make INPUT NAME latching Example Make alarm latching This sets the Input to a latched Input and the system responds with The Input INPUT NAME is now a latching input Set an Input as a Non latched Input Command Make INPUT NAME nonlatching Example Make alarm non latching This sets the Input...

Страница 13: ...hich inputs are linked to which outputs if there are no links the response is Currently Input1 is not linked to an output Currently Input2 is not linked to an output Input Tick Off Feature The inputs can have a Tick Off feature if this feature is turned on and an input is on the unit will send a reminder text every 10 minutes until the text command Tick INPUT NAME off is sent max number of texts 2...

Страница 14: ...g To program the feature The Command for Input1 is Message1 please close the gate after using If everything is fine the system responds with The reply message has been set to please close the gate after using To turn the feature off and set back to factory settings simply send The Command for Input1 is Message1 If everything is fine the system responds with The reply message has been set back to t...

Страница 15: ...also be programmed so when ever the Turn output On command is sent the output will turn on for the programmed time Command Set OUTPUT NAME on time to XX mins or hrs or days If everything is fine the system responds with The OUTPUT NAME on time has been set to XX mins or hrs or days If no value is set the system will respond with The OUTPUT NAME has been turned on and will stay on because no time o...

Страница 16: ...en set as per above the defalt time is 3 seconds and the system responds with OUTPUT NAME is now a pulsing output with a defalt pulse time of 3 seconds If the Output was initially On when the Output was set the system responds with OUTPUT NAME is now a pulsing output and has been turned off in preparation for use If the Output is linked to an Input when the Input is triggered the system sends INPU...

Страница 17: ...n the feature off Command Make OUTPUT NAME nonsave The system responds with The output condition will not saved Note If you want this for both outputs then the command needs to be sent for both outputs Set Battery Alarm Trigger Voltage Command Change battery alarm to XX X Where XX X can be between 8 and 30 volts The system responds with The low voltage alarm has been set to XX X volts and the alar...

Страница 18: ...mand needs to be set to reset the latched alarm If it is set to non latching the battery alarm will reset once the battery voltage has increased by 5 volts The system default is non latching Command Make battery alarm latching System responds with The battery alarm is now latching Command Make battery alarm nonlatching System responds with The battery alarm is now nonlatching Reset a latched Batte...

Страница 19: ...ng on the above Set alarm reset temperatures Both low and high alarm temperatures will be automatically reset approx 3 degrees above or below the temperatures depending on if the alarm is low or high OR the reset levels can be programmed Command Set temp yyy reset to xxx degrees where yyy is either high or low xx is the temperature Note is a minus temperature is required place the symbol before th...

Страница 20: ... time in minutes e g Set low temp on delay to 5 mins The system responds with The low alarm delay on time has been set to 5 mins Linking alarms to outputs Both low and high alarm can be linked to an output Command Link xxxx alarm to OUTPUT NAME xxxx can be the word low or high OUTPUT NAME the name of the output The system responds with The temperature xxxx alarm has been linked to OUTPUT NAME wher...

Страница 21: ...live text to All users to mask users below To turn the feature off Command Turn alive text off If everything is fine the system responds with This feature has been disable Masking Alive texts only available in ver 1 0 5 or later This feature allows you to mask the Alive text so only the programmed users will receive the Alive text and not all users The default setting is all users will receive the...

Страница 22: ...ting the Unit Command Reboot The system responds with Module is not resetting Reset Unit to Factory Defaults WARNING This command restores the unit to factory defaults therefore all settings will be lost Command Factory Reset The unit responds with The unit has been restored to factory settings and all memory has been cleared Ezy Switch SMS TEMP 2 Installation Operation Manual ...

Страница 23: ...placed product as its property The equipment has been installed correctly and is used in accordance with the instructions issued with the product In no event will Penguin Electronics Ltd or its agents accept any liability for any direct indirect or consequential losses or damages whatsoever or howsoever arising from the use of the product Where conditions or warranties are implied or other rights ...

Страница 24: ...has been turned on If the input turns back off before the programmed time delay expires the input is reset and the time starts back at zero If the input is linked to an output it will also state the linked output has also been turned on Off Delay This delay is used when the input turns OFF Example If input1 has an OFF delay of 10mins when Input1 turns OFF the unit will wait 10 minutes then send th...

Страница 25: ... degrees area Low alarm temp in degrees area Low Alarm The unit will alarm if the current temperature is equal to or less than the programmed low set point temperature e g set point 15 degrees alarm point will be equal or less than 15 degrees e g set point 15 degrees alarm point will be equal or greater than 15 degrees Ezy Switch SMS TEMP 2 Installation Operation Manual 15 10 0 0 10 Alarm set poin...

Страница 26: ...lace aerial with high gain aerial 2 Move unit to different location 3 SIM card not installed 4 SIM has a pin number remove 5 SIM is locked remove lock LED slow flashes every 3 seconds But no texts are sent or received The unit can find the GSM network hence the slow flashes but the signal strength is to low 1 Replace aerial with high gain aerial 2 Move unit to different location 3 SIM card NOT reg...

Страница 27: ...27 All technologies design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 2 1 ...