System Monitor 

Installation Manual 

Applicable for firmware version 1.1 or above  

 

 

Содержание SMS-16

Страница 1: ...EZY SWITCH LIMITED SMS 16 System Monitor Installation Manual Applicable for firmware version 1 1 or above ...

Страница 2: ...uts 13 Link an Input to an Output 14 Get linked information 14 Setup Input Tick off 14 Turn an Output ON or OFF 15 Turn an Output ON for a set time 16 Invert Output 16 Make an Output Pulse On and Off 16 Clear Output Pulse Set to non pulsed 16 Make Output public 17 Turn Output response On Off 17 Save Output Status 17 Linking Outputs 17 Set Battery Alarm trigger voltage 18 Link Battery Alarm to Outp...

Страница 3: ...osed Inputs o Programmable for Normally Open or Normally Closed Outputs Inputs and Outputs names are user programmable via text command up to 20 characters Link any Input to any Output Example Link intruder sensor or smoke detector input to light or alarm horn output Monitors battery supply voltage and sends alarm message if low battery is detected at below the programmed alarm setting On demand u...

Страница 4: ...ing Input Input 4 Positive switching Input Input 5 Negative switching Input Input 6 Negative switching Input Input 7 Negative switching Input Input 8 Negative switching Input Connections SMS 16 Terminal Electrical Specifications Batt Battery positive 10 to 30vdc Batt Battery negative Outputs sink max 400 Ma each Positive Inputs Inputs 1 2 3 4 max Input voltage 36vdc Upper Tier Terminals Lower Tier...

Страница 5: ...every 3 seconds this indicates the cellular network has been found all ok Electrical Specifications Ezy Switch Ltd System Ezy Switch SMS 16 Installation Operation Manual Supply Voltage Quiescent Current Data Retention Outputs Max Input voltage 12 to 30 Volts DC 800mA 40 Milli amps 10 years without power Sink max 400 mA each 30vdc SIM Card Signal LED SIM Card Terminal 1 Terminal 10 Terminal 11 Term...

Страница 6: ...cian must be used when connecting to the 120 240v main supply voltage Relay Connection for AC AC Appliance or other 120 240v AC Device To either Output 1 2 3 4 5 6 7 or 8 terminal on the SMS Unit Batt terminal on the SMS Unit 230 VAC relay with a 12 VDC Coil AC Relay Connection for DC To whatever you want to connect to 12 or 24 VDC To either Output 1 2 3 4 5 6 7 or 8 terminal on the SMS Unit Relay...

Страница 7: ...ositive switching to Battery or VE and four are Negative switching to Ground Positive switching Inputs 1 4 Negative switching Inputs 5 8 Ezy Switch SMS 16 Installation Operation Manual SMS 16 Input Switch VE SMS 16 Input Switch GND NOTE Inputs ...

Страница 8: ...mber without the preceding 0 If the users number is 0414884900 then Command add user 65414884900 USA Canada 001 1 and the Area Code Number If the users number is 414 555 1434 then Command add user 14145551434 IMPORTANT Ezy Switch SMS 16 Installation Operation Manual NOTE If a user sends a text message to the system which is not an exact match with the commands the system responds with Sorry either...

Страница 9: ... number XXXXXXXX has been added to the user list Removing a User Command Remove user XXXXXXXX see Country Code page 8 If you try to remove the only user the system responds with Cannot delete the only user If the number sent is not currently on the list the system responds with XXXXXXXX is not currently in the user list so cannot be removed please check the number and try again If everything is ok...

Страница 10: ...he unit using the Add User command as per above If User lookup is Off the SMS 8 will respond to any number that sends the correct command The system responds with The user lookup list feature has been turned on and the unit will only accept commands from programmed users OR The user lookup list feature has been turned off and the unit will only accept commands from any numbers PLEASE NOTE Input ch...

Страница 11: ...en input2 is turned on output2 will turn on when input2 is turned off output2 will turn off When input3 is turned on output3 will turn on when input3 is turned off output3 will turn off When input4 is turned on output4 will turn on when input4 is turned off output4 will turn off When input5 is turned on output1 will turn on when input5 is turned off output1 will turn off When input6 is turned on o...

Страница 12: ...to rename is not currently in the list the system responds with Sorry either that device does not exist or the message format is not understood please check the spelling and try again If the new name chosen does not fulfill the requirements of a name the system responds with Sorry that name is not allowed please check that it is between 1 and 20 characters long If everything is ok the system respo...

Страница 13: ...ing Example Make alarm non latching The system responds with The Input INPUT NAME is now a nonlatching input Reset a latched Input used to return Input to non activated state Command Reset INPUT NAME Example Reset alarm The system responds with INPUT NAME is no longer in a latched state and will begin to be monitored again If the Input is not latched the system responds with INPUT NAME latch is no...

Страница 14: ...The inputs can have a Tick Off feature if this feature is turned on and an input is on the unit will send a reminder text every 5 minutes until the text command Tick INPUT NAME off is sent max number of texts 20 To turn the feature on Command Make INPUT NAME tickoff on If everything is fine the system responds with The input tickoff feature has been turned on To turn the feature off Command Make I...

Страница 15: ...ut Off command is sent The Output on time XX can also be programmed so when ever the Turn output On command is sent the output will turn on for the programmed time Command Set OUTPUT NAME on time to XX mins or hrs or days If everything is fine the system responds with The OUTPUT NAME on time has been set to XX mins or hrs or days If no value is set the system will respond with The OUTPUT NAME has ...

Страница 16: ...been set as per above the defalt time is 3 seconds and the system responds with OUTPUT NAME is now a pulsing output with a defalt pulse time of 3 seconds If the Output was initially On when the Output was set the system responds with OUTPUT NAME is now a pulsing output and has been turned off in preparation for use If the Output is linked to an Input when the Input is triggered the system sends IN...

Страница 17: ...e text will not be sent Save Output Status This command is used to define if the output state is saved to memory and restored to it state after a power recycle E g if an output was On when the power was turned off then when the power is restored the output will turn back on Note this does not apply if an output was turned on for a specified time System default is not saved Command Make OUTPUT NAME...

Страница 18: ...set If the value XX X is outside the settings the system responds with Because the value is out of range the voltage alarm has been set to 11 5 volts and the alarm has been reset Link the Battery Alarm to an Output Note only output 1 2 3 or 4 can be linked Command Link battery alarm to OUTPUT NAME The system responds with The battery alarm has successfully been linked to OUTPUT NAME and the alarm ...

Страница 19: ... the system responds with The battery alarm has been cleared and will begin to be monitored again the linked output has also been turned off If the alarm is not currently set the system responds with The battery alarm is not currently active and does not need to be cleared Alive text feature This unit has an alive text feature which will send out a alive text as often as it has been programmed for...

Страница 20: ...them input 1 has the highest and input 8 the lowest For example in input 3 is turned on only inputs 1 or 2 can activate inputs 4 5 6 7 or 8 will not activate and be ignored so only a higher input than the one that is currently activated will activate To set feature Command Priority XX where XX is either on or off If everything is fine the system responds with The input priority feature has been tu...

Страница 21: ...tting the Unit Command Reboot The system responds with Module is now resetting Reset Unit to Factory Defaults WARNING This command restores the unit to factory defaults therefore all settings will be lost Command Factory Reset The unit responds with The unit has been restored to factory settings and all memory has been clear Ezy Switch SMS 16 Installation Operation Manual ...

Страница 22: ...replaced product as its property The equipment has been installed correctly and is used in accordance with the instructions issued with the product In no event will Penguin Electronics Ltd or its agents accept any liability for any direct indirect or consequential losses or damages whatsoever or howsoever arising from the use of the product Where conditions or warranties are implied or other right...

Страница 23: ... 10 minutes then send the following text message Input Name has been turned on If the input turns back off before the programmed time delay expires the input is reset and the time starts back at zero If the input is linked to an output it will also state the linked output has also been turned on Off Delay This delay is used when the input turns OFF Example If input1 has an OFF delay of 10mins when...

Страница 24: ...ifferent location 3 SIM card not installed 4 SIM has a pin number remove 5 SIM is locked remove lock LED slow flashes every 3 seconds But no texts are sent or received The unit can find the GSM network hence the slow flashes but the signal strength is to low 1 Replace aerial with high gain aerial 2 Move unit to different location 3 SIM card NOT registered with the network provider 4 No credit on t...

Страница 25: ...f shore power is lost the SMS 16 will send a text message to all Users saying Shore Power has turned off To avoid any nuisance text message s caused by a tripped breaker or someone temporarily using your power outlet you should set the OFF delay for this Input a 15 minute delay is appropriate for most situations To set the delay simply send a text command Change Shore Power off delay to 15 min as ...

Страница 26: ... now latched When the alarm has been triggered you can reset it by sending the txt Reset Sensor If you want to connect a siren and or flashing light to output1 then Send command text Link Sensor to output1 Send command text Change output1 to Siren When the unit detects movement you will receive a text message and the siren and or flashing light will turn On The input Sensor has been turned on and ...

Страница 27: ... normally closed and go open when activated When the unit detects movement you will receive the following text message The input Door Sensor has been turned on and is now latched When the alarm has been triggered you can reset it by sending the txt Reset Door Sensor If you want to connect a siren and or flashing light to output1 then Send command text Link Door Sensor to output1 Send command text ...

Страница 28: ... All technologies design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 1 1 Ezy Switch SMS 16 Installation Operation Manual ...