background image

 

 

Installation & Maintenance 

H373D / H373S & H366D / H366S 

 

 

 

CLASS I,  IP65 

 

EL-IM005.00 

Page 1 of 2 

 

 

 

 

 

 

 

 

 

 

  

      

 

 
Installation 

 
The Eye Lighting H373 and H366 series’ are floodlights for 
outdoor (permanent) use, designed to be operated in 
conjunction with remote control gear appropriate for the lamp 
type and wattage in use. 
 
The floodlights are designed to be securely mounted on a 
suitably solid horizontal surface using 2x M16 bolts. 
 
Attach the lamp carrier to the main body by snapping its hinge 
pin into the cradle on the body.   
 
Screw the lamp in to its full extent, ensuring that it’s secure, 
but not over tightened.   
 
Ensuring the gasket and joining surfaces are clean, secure the 
lamp carrier to the main body by pivoting the three screws and 
tightening the wing nuts evenly

.

 

 
Incoming supply cables from the control gear are terminated in 
the termination box via the 20mm threaded entry. 
 
To maintain the integrity of the enclosure’s protection against 
dust and moisture ingress, cable glands or conduit fittings 
rated at least IP65 must be used. 
 
Check that the cable glands are tightened correctly. 
 
Floodlights must be installed within the maximum 
recommended distance to the control gear, as applicable to 
the type used. 
 
These instructions should be retained by the floodlight owner 
for reference, and made available as necessary, to ensure 
future maintenance is carried out correctly. 
 
 
 

 
 
 
 
 

 

 

 

Aiming 

 
Adjust the horizontal aiming of the floodlight by loosening the 
anchor and swivel screws (not supplied) fixing the base to the 
mounting surface.  Using the markings on the base plate as a 
guide, adjust to the required angle and tighten the screws.  
 
Adjust the tilt by loosening the screws at the pivot point and 
releasing the locking lever.  Using the markings on the pivot 
plate, adjust the floodlight to the required tilt angle and hold in 
place by tightening the lever.  Check the tilt angle is correct 
and tighten the screws. 
 

 
 

General Operation and Maintenance 

 

Failed lamps are to be replaced promptly, or the circuit 
isolated, to avoid possible control gear damage.  Continual 
operation on supply voltage above that nominated on the 
control gear will reduce expected lamp and component life. 
 
Clean excessive build up of foreign material from outer 
surfaces of the body.  Clean the lens as required with warm 
water and mild detergent. 
 
Screws requiring loosening for future service and lamp 
replacement should be greased for ease of maintenance. Use 
silicone base grease only as oil base grease may damage 
some components. 
 
Luminaires with damaged or cracked glass shall be removed 
from service immediately. 
 
Continuously operated lamps should be turned off at least 
once a week for 1 hour. 
 

 
 

Lamp Replacement 

 
The floodlight is to be wiped clean of all dust and debris prior 
to disassembly. 
 
Loosen the three wing nuts and pivot the fixing screws away 
from the lamp carrier and swing the carrier away from the 
body. 
  
Replace the lamp only with a type and wattage suitable for the 
control gear in use.  Screw the lamp in to its full extent, 
ensuring that it’s secure, but not over tightened. 
 
Ensure gasket and joining surfaces are clean, return the lamp 
carrier to its position and evenly tighten the wing nuts. 
 
 
 
 
 
 
 

                                      

 

               

 

 

  