8 Type Codes
iWAP200 Zone 2 Access Point Enclosure
iWAP200-[#1]-[#2]-[#3]-[#4]-[#5]-[#6]-[#7]-[#8]-[#9]
Specify option [#1] - Wireless Network Hardware
Hardware supplied by Customer*
C
Hardware supplied by Extronics
E
Specify option [#2] - Type Of Wireless Network Hardware
Cisco AP1242 Access Point
(No heating/Cooling:
-20
o
C to
45
o
C, with heating/cooling
-40
o
C to 55
o
C)
6
Cisco AP1242 LAP Light Access Point
(No heating/Cooling:
-20
o
C to
45
o
C, with heating/cooling
-40
o
C to 55
o
C)
7
Acksys WLG-LINK-OEM
(No heating/Cooling:
-20
o
C to
60
o
C, with heating/cooling
-40
o
C to 70
o
C)
26**
Firetide 7000 Series MESH Router
(No heating/Cooling:
0
o
C to
50
o
C, with heating/cooling
-20
o
C to 60
o
C)
30
AeroScout Location Receiver
(No heating/Cooling:
0
o
C to
50
o
C, with heating/cooling
-40
o
C to 60
o
C)
31
Cisco AIR-CAP3502E / AIR-CAP3501E
(No heating/Cooling:
-20
o
C to
45
o
C, with heating/cooling
-30
o
C to 55
o
C)
33
Aruba AP-92
(No heating/Cooling:
0
o
C to
40
o
C, with heating/cooling
-40
o
C to 50
o
C)
42
Firetide 4500 Series Access Points
(No heating/Cooling:
0
o
C to 4
0
o
C, with heating/cooling
-20
o
C to 50
o
C)
43
**(Note: Acksys WLG-LINK-OEM is NOT currently compatible with an 802.3af POE input. For option #3 only AC or DC input may be
chosen)
*Extronics can supply the above wireless network hardware, alternatively you may wish to “free issue” one of the above soluti
ons so that
we can factory fit it. New hardware not already on the list above will need to be assessed and certified to determine its
suitability.
Please note that in order to meet the requirements of the certification Extronics has to take the internal PCB's from the Access Point
enclosure and make minor modifications to them. This will invalidate the warranty from the original manufacturer. If you wish the
wireless network hardware to have a 12 month warranty like the iWAP200 enclosure system is supplied with then Extronics must supply
the wireless hardware. Select order code E for [#1] if you require Extronics to supply the wireless network hardware.
Specify option [#3] - Power Supply
Universal 90-264VAC (If heater option [#7] selected, the unit cannot have a universal voltage, it will be either 115VAC or 230VAC) AC
24V DC
DC
IEEE802.3af compliant Power-Over-Ethernet
POE
Note: If AC option is selected, the unit can be powered by either AC supply or POE supply
Specify option [#4] - Ethernet Connection
10/100BaseT Ethernet on CAT5 copper
C
Multimode 10/100BaseFX fibre with ST connector (Note : minimum ambient temperature 0
o
C without heaters)
F
Single mode 100BaseLX-10 fibre with SC connector (Note: minimum ambient temperature 0
o
C without heaters)
S
Specify option [#5] - Number of Antenna Outputs for Radio 1
0 off N-type connector
0
1 off N-type connector
1
2 off N-type connector
2
3 off N-type connector
3
0 off N-type connector with surge protector
0S
1 off N-type connector with surge protector
1S
2 off N-type connector with surge protector
2S
3 off N-type connector with surge protector
3S
Specify option [#6] - Number of Antenna Outputs for Radio 2
0 off N-type connector
0
1 off N-type connector
1
2 off N-type connector
2
3 off N-type connector
3
0 off N-type connector with surge protector
0S
1 off N-type connector with surge protector
1S
2 off N-type connector with surge protector
2S
3 off N-type connector with surge protector
3S
Specify option [#7] - Enclosure Heating (not compatible with universal 90-264VAC
or
POE supplies)
No enclosure heating - T4/T5 temperature classification
N
230VAC enclosure heating - T3 temperature classification
H1
115VAC enclosure heating - T3 temperature classification
H2
24VDC enclosure heating - T3 temperature classification
H3
Specify option [#8] - Enclosure cooling (not compatible with POE supply)
No enclosure cooling
N
Enclosure cooling fitted
C
Specify option [#9] - Enclosure Cable Entry
Metal compression Cable glands fitted
G
No Glands fitted, M20 entries provided for installer to provide own glands or blacking plugs/sockets
N
Accessories
Pipe mount bracket kit to enable the unit to be fixed to a pipe or rectangular post. (2 kits required for complete fitment) iWAPMB01