8  Type Codes 

iWAP200 Zone 2 Access Point Enclosure 

 

iWAP200-[#1]-[#2]-[#3]-[#4]-[#5]-[#6]-[#7]-[#8]-[#9]

 

 
Specify option [#1] - Wireless Network Hardware 

Hardware supplied by Customer* 

 

 

 

 

 

 

 

 

Hardware supplied by Extronics   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify option [#2] - Type Of Wireless Network Hardware   

Cisco AP1242 Access Point 

 

(No heating/Cooling: 

-20

o

C to 

45

o

C, with heating/cooling

 -40

o

C to 55

o

C) 

 

Cisco AP1242 LAP Light Access Point 

(No heating/Cooling: 

-20

o

C to 

45

o

C, with heating/cooling

 -40

o

C to 55

o

C) 

 

Acksys WLG-LINK-OEM  

 

(No heating/Cooling: 

-20

o

C to 

60

o

C, with heating/cooling

 -40

o

C to 70

o

C) 

 

26**

 

Firetide 7000 Series MESH Router 

(No heating/Cooling: 

0

o

C to 

50

o

C, with heating/cooling

 -20

o

C to 60

o

C) 

 

30 

AeroScout Location Receiver 

 

(No heating/Cooling: 

0

o

C to 

50

o

C, with heating/cooling

 -40

o

C to 60

o

C) 

 

31 

Cisco AIR-CAP3502E / AIR-CAP3501E 

(No heating/Cooling: 

-20

o

C to 

45

o

C, with heating/cooling

 -30

o

C to 55

o

C) 

 

33 

Aruba AP-92 

 

 

(No heating/Cooling: 

0

o

C to 

40

o

C, with heating/cooling

 -40

o

C to 50

o

C) 

 

42 

Firetide 4500 Series Access Points 

(No heating/Cooling: 

0

o

C to 4

0

o

C, with heating/cooling

 -20

o

C to 50

o

C) 

 

43 

 
 
**(Note: Acksys WLG-LINK-OEM is NOT currently compatible with an 802.3af POE input. For option #3 only AC or DC input may be 
chosen) 

 

 

 

*Extronics can supply the above wireless network hardware, alternatively you may wish to “free issue” one of the above soluti

ons so that 

we can factory fit it.   New hardware not already on the list above will need to be assessed and certified to determine its 
suitability.  
 
Please note that in order to meet the requirements of the certification Extronics has to take the internal PCB's from the Access Point 
enclosure and make minor modifications to them. This will invalidate the warranty from the original manufacturer. If you wish the 
wireless network hardware to have a 12 month warranty like the iWAP200 enclosure system is supplied with then Extronics must supply 
the wireless hardware. Select order code E for [#1] if you require Extronics to supply the wireless network hardware.  
 

Specify option [#3] - Power Supply 

Universal 90-264VAC (If heater option [#7] selected, the unit cannot have a universal voltage, it will be either 115VAC or 230VAC) AC 
24V DC 

 

 

 

 

 

 

 

 

 

 

 

DC 

IEEE802.3af compliant Power-Over-Ethernet 

 

 

 

 

 

 

 

POE 

 
Note: If AC option is selected, the unit can be powered by either AC supply or POE supply 

 

Specify option [#4] - Ethernet Connection 

10/100BaseT Ethernet on CAT5 copper 

 

 

 

 

 

 

 

 

Multimode 10/100BaseFX fibre with ST connector (Note : minimum ambient temperature 0

o

C without heaters) 

 

Single mode 100BaseLX-10 fibre with SC connector (Note: minimum ambient temperature 0

o

C without heaters) 

 

S

 

 

 

Specify option [#5] - Number of Antenna Outputs for Radio 1  

0 off N-type connector 

 

 

 

 

 

 

 

 

 

1 off N-type connector 

 

 

 

 

 

 

 

 

 

2 off N-type connector 

 

 

 

 

 

 

 

 

 

3 off N-type connector 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 off N-type connector with surge protector 

 

 

 

 

 

 

 

0S 

1 off N-type connector with surge protector 

 

 

 

 

 

 

 

1S 

2 off N-type connector with surge protector 

 

 

 

 

 

 

 

2S 

3 off N-type connector with surge protector 

 

 

 

 

 

 

 

3S 

 

Specify option [#6] - Number of Antenna Outputs for Radio 2  

0 off N-type connector 

 

 

 

 

 

 

 

 

 

1 off N-type connector 

 

 

 

 

 

 

 

 

 

2 off N-type connector 

 

 

 

 

 

 

 

 

 

3 off N-type connector 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 off N-type connector with surge protector 

 

 

 

 

 

 

 

0S 

1 off N-type connector with surge protector 

 

 

 

 

 

 

 

1S 

2 off N-type connector with surge protector 

 

 

 

 

 

 

 

2S 

3 off N-type connector with surge protector 

 

 

 

 

 

 

 

3S 

 

 

 

 

 

 

 

 

 

 

Specify option [#7] - Enclosure Heating (not compatible with universal 90-264VAC

 

or

 

POE supplies) 

No enclosure heating - T4/T5 temperature classification   

 

 

 

 

 

 

230VAC enclosure heating - T3 temperature classification   

 

 

 

 

 

H1 

115VAC enclosure heating - T3 temperature classification   

 

 

 

 

 

H2 

24VDC enclosure heating - T3 temperature classification 

 

 

 

 

 

 

H3 

 

Specify option [#8] - Enclosure cooling (not compatible with POE supply) 

No enclosure cooling   

 

 

 

 

 

 

 

 

 

Enclosure cooling fitted 

 

 

 

 

 

 

 

 

 

 

Specify option [#9] - Enclosure Cable Entry 

Metal compression Cable glands fitted 

  

      

 

 

 

 

 

 

No Glands fitted, M20 entries provided for installer to provide own glands or blacking plugs/sockets 

 

 

 

Accessories 

Pipe mount bracket kit to enable the unit to be fixed to a pipe or rectangular post. (2 kits required for complete fitment) iWAPMB01

 

 
 

Содержание iWAP200

Страница 1: ...Installation Operating Manual iWAP200...

Страница 2: ...is document is Copyright Extronics limited Extronics reserve the right to change this manual and its contents without notice the latest version applies Warranty For full details of the Extronics warra...

Страница 3: ...Input 13 3 1 7 Thermostat Control 13 3 1 8 Fitting the antennas 13 3 1 9 Mounting The Antennas 14 3 1 10 Setting to work 15 4 Intended Purpose Usage 16 4 1 Transportation and Storage 16 4 2 Authorize...

Страница 4: ...that Extronics can provide an OEM a solution to enable your WLAN network devices to be installed in hazardous areas The Extronics iWAP200 is designed for use with one to four standard antennas or Ext...

Страница 5: ...ng the relevant standards and where applicable in accordance with IEC 79 17 on electrical apparatus for explosive atmospheres Warning For the installation maintenance and cleaning of the units it is a...

Страница 6: ...re ensure the assembly is mounted using suitable fixtures Caution When powering the iWAP200 via POE do not apply an external power supply to the protection board Caution Never power the iWAP200 via PO...

Страница 7: ...nformation Do not exceed the Effective Isotropic Radiated Power EIRP limit for the country region of operation Information For legacy reasons the RF outputs of the iWAP200 remain approved in accordanc...

Страница 8: ...io 2 R2 on any manufacturers Wireless Access point A will be antenna port 1 B will be antenna port 2 and C will be antenna port 3 For example If you have ordered 1 N type connector for Radio 1 and 2 N...

Страница 9: ...supplied by Extronics are used these must be M20 sized cable glands meeting the requirements of EN60079 0 2009 for ATEX Category III GD equipment and not compromise the IP66 rating of the iWAP200 encl...

Страница 10: ...e to these screw terminals for the connection of the Ethernet input The pinouts on this terminal correspond with the standard cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be...

Страница 11: ...s made via a SC connector Important The fibre cable must enter the iWAP200 enclosure via a cable gland it therefore may be necessary to terminate the Fibre cable with the correct connector from within...

Страница 12: ...inouts on this terminal correspond with the standard Cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be made only use either the terminals or RJ45 connector NOT both Ethernet I...

Страница 13: ...s are currently not user configurable The default configuration is for the heaters to be turned on when the internal ambient temperature is between 20oC and 30oC and for the fans wireless hardware to...

Страница 14: ...ve been approved for use by Extronics for the area which they are to be installed may be used with iWAP200 Important Any plastic coated antenna shall have a warning label fitted to it stating WARNING...

Страница 15: ...ighten screws Refer to the original manufacturers instructions for a detailed information on setting the network to work correctly Important Ensure the lid is secure correct cable glands are fitted an...

Страница 16: ...red that they are not subjected to any excessive mechanical stresses 4 2 Authorized Persons Only persons trained for the purpose are authorized to handle the iWAP200 they must be familiar with the uni...

Страница 17: ...bserve the applicable regulations and provisions concerned with explosion protection EN 60079 0 EN 60079 14 as well as the Accident Prevention Regulations 4 5 Cleaning and Maintenance Intervals The cl...

Страница 18: ...e input option on ST connectors 100BaseLX 10 Single mode fibre on SC connectors Note that connectors may be specified as an option in the ordering data Output Connections Up to 6 energy limited extern...

Страница 19: ...Operating Manual 19 6 Enclosure Dimensions...

Страница 20: ...77 5000 Fax 44 0 845 277 4000 E mail Info extronics com W eb www extronics com xxxx Voltage EPSILON 08 ATEX 2394X II 3G Ex nAnL IIC T3 20 C Ta 70 C T4 20 C Ta 65 C T5 20 C Ta 30 C EPSILON 08 ATEX 2395...

Страница 21: ...ire Extronics to supply the wireless network hardware Specify option 3 Power Supply Universal 90 264VAC If heater option 7 selected the unit cannot have a universal voltage it will be either 115VAC or...

Страница 22: ...Operating Manual 22 9 EU Declaration of Conformity...

Страница 23: ...Operating Manual 23...

Отзывы: