background image

 

 

 

                                                         

 

 
 

Operating Manual 

iANT100, iANT101  

 
 
 
 
 
 
 
 

 
 
 

 

 
 

Содержание iANT100

Страница 1: ...Operating Manual iANT100 iANT101...

Страница 2: ...is intentionally left blank Document Number 314666 8 2018 Extronics Limited This document is Copyright Extronics limited Extronics reserve the right to change this manual and its contents without noti...

Страница 3: ...ANTMB04 10 3 2 5 iANTMB05 10 3 2 6 iANTMB06 11 4 Technical Specification 12 4 1 Antenna polar patterns and VSWR Plots 12 4 1 1 iANT100 101 2 4 GHz 5 GHz 12 4 1 2 iANT100 GSM Quad Band 13 4 1 3 iANT101...

Страница 4: ...sion proof Access Points such as the Extronics iWAP101 iWAP103 or an Access Point installed in a safe area and just the antenna installed in the hazardous area The units are explosion protected in acc...

Страница 5: ...2 3 List of Notes The notes supplied in this chapter provide information on the following Danger Warning o Possible hazard to life or health Caution o Possible damage to property Important o Possible...

Страница 6: ...azardous area the flying lead shall be installed in an appropriately certified enclosure An example would be termination inside a flameproof enclosure via a suitable certified flameproof gland Importa...

Страница 7: ...ld be mounted at least 600mm 24 apart for optimal performance but will perform well closer together Information The iANT100 has optional brackets which allow the antenna to be mounted directly to Extr...

Страница 8: ...y for example an M30 should be used or the connector should be fitted after gland installation Select either the connector supplied separately option for the iANT101 or use a larger entry as appropria...

Страница 9: ...teel bracket kit 365mm length for two iANT100 antennas This bracket can be fitted onto or away from the iWAP enclosure 3 2 3 iANTMB03 316L stainless steel wall mount bracket kit for iANT100 antenna Th...

Страница 10: ...el ceiling mount bracket kit for iANT100 antenna This bracket is fitted away from the iWAP enclosure 3 2 5 iANTMB05 316L stainless steel bracket kit 365mm length for three iANT100 antennas This bracke...

Страница 11: ...Operating Manual 11 3 2 6 iANTMB06 316L stainless steel bracket kit 430mm length for three iANT100 antennas This bracket can be fitted onto or away from the iWAP enclosure...

Страница 12: ...Hz 5 GHz iANT100 101 2 4GHz E Plane Pattern Vertical Free Space 3dB Beam Width Approx 34 iANT100 101 2 4 GHz H Plane Pattern Vertical Free Space Omni Directional iANT100 101 5 GHz E Plane Pattern Vert...

Страница 13: ...lot 1 8 1 2350 2550 MHz iANT100 101 5GHz VSWR 2 1 5000 6000 MHz 4 1 2 iANT100 GSM Quad Band iANT100 GSM Quad Band E Plane Pattern Vertical Free Space Beam Width Approx 80 iANT100 GSM Quad Band H Plane...

Страница 14: ...1 1750 1850MHz iANT100 GSM Quad Band VSWR Plot 2 1 860 940 MHz 4 1 3 iANT101 437 458 5 466MHz iANT101 437 458 5 466MHz E Plane Pattern Vertical Free Space Beam Width Approx 80 iANT101 437 458 5 466MHz...

Страница 15: ...re as standard other lengths on request Supplied as 5 metre as standard other lengths on request Supplied as 5 metre as standard other lengths on request Frequency 2300 2500MHz 5150 5875MHz GSM 850 90...

Страница 16: ...r 250mm Length 38mm Diameter 330mm Length 38mm Diameter Weight 480g Not including Cable 480g Not including Cable 510g Not including Cable Connections Please Specify with Order Please Specify with Orde...

Страница 17: ...Mounting Antenna supplied with galvanised steel pipe mounting bracket for 38mm pipe Optional 316L stainless steel wall mounting bracket also available Antenna supplied with galvanised steel pipe moun...

Страница 18: ...tresses 5 2 Cleaning and Maintenance The iANT and all its components require no maintenance and are self monitoring All work on the iANT100 or iANT101 by personnel who are not expressly qualified for...

Страница 19: ...ructions are intended only for when the iANT100 is to be used with the iWAP range of enclosures For full installation instructions also refer to Peppers CR UB assembly instructions Contact Extronics f...

Страница 20: ...Operating Manual 20 Figure 5 Figure 6 Figure 7...

Страница 21: ...Operating Manual 21 Figure 8 Figure 9...

Страница 22: ...er to approximately 40mm in length as shown in figure 4 7 Pass the cable through and push compound into Entry Body until Rear Assembly engages Remove squeezed out compound as Screw Union full turns on...

Страница 23: ...that the Extronics iWAP103 is supplied with M25 cable entries and M25 M20 thread reducers as standard Specify option 4 Connector fitting Selected connector fitted F Crimp connector supplied separately...

Страница 24: ...for a right angle N type connector fitted to the cable to pass through the enclosure entry for an M20 or M25 cable gland The connector must be fitted after passing the cable through the enclosure hole...

Страница 25: ...Operating Manual 25 8 EC Declaration of Conformity...

Страница 26: ...Operating Manual 26...

Страница 27: ...Operating Manual 27 9 ATEX IECEx CERTIFICATION...

Страница 28: ...Operating Manual 28...

Страница 29: ...Operating Manual 29...

Страница 30: ...Operating Manual 30...

Страница 31: ...Operating Manual 31...

Страница 32: ...Operating Manual 32...

Страница 33: ...Operating Manual 33...

Страница 34: ...you allege that goods are totally unfit for their purpose they must be returned within 7 days of receipt Site Warranty is expressly excluded from these terms and conditions unless agreement is made in...

Отзывы: