XTRA Full Rack Power Amplifier Series • Operation
16
Bridged Mode Output
XPA 4002 bridged mono output speaker wiring
In bridged mode, the output mode toggle switch for Input 1 must be set to the bridged (up)
position (see figure 8 below).
For Input 1:
The channel
1
+ output terminal becomes the b output terminal and
the channel
2
+ output terminal becomes the bridged “-” output terminal (see figure 14).
8 Ohm
BRIDGE MODE
8Ω / 4Ω OUTPUTS
CLASS 2 WIRING
1
2
ON
OFF
BRIDGE
8Ω ONLY
BRIDGE
Figure 14.
XPA 4002 Bridged Mono Output Wiring
On the input end, only Input 1 is used in bridged mode.
1
2
(BRIDGE)
INPUTS
XPA 4002 bridged mono output using parallel speaker wiring
In bridged mode, the output mode toggle switch for input 1 must be set to the bridged (up)
position (see figure 7 below).
The channel
1
+ output terminal becomes the b output terminal and the channel
2
+ output terminal becomes the bridged - output terminal (see figure 15 below).
8 Ohm
Total
Load
Two 16-ohm speakers wired in parallel equal an 8-ohm load.
BRIDGE MODE
8Ω / 4Ω OUTPUTS
CLASS 2 WIRING
1
2
ON
OFF
BRIDGE
8Ω ONLY
BRIDGE
Mono
–
Mono
+
16
ohms
16
ohms
Figure 15.
XPA 4002 Bridged Mono Output Parallel Wiring
On the input end, only Input 1 is used in bridged mode.
1
2
(BRIDGE)
INPUTS
14