background image

User Guide

XTRA

 Full Rack Series:

Audio Products

Full-Rack 2-, 3-, and 4-Channel Mono and Stereo Audio 
Power Amplifiers

68-783-01 Rev. F

0

4 20

   

XPA 2002-70V

   

XPA 2004

   

XPA 2002-100V

   

XPA 4002

   

XPA 2003C-70V 

   XPA 2003C-100V

   

XPA 4002-70V 

Содержание XTRA FULL RACK XPA 2002-70V

Страница 1: ...TRA Full Rack Series Audio Products Full Rack 2 3 and 4 Channel Mono and Stereo Audio Power Amplifiers 68 783 01 Rev F 04 20 XPA 2002 70V XPA 2004 XPA 2002 100V XPA 4002 XPA 2003C 70V XPA 2003C 100V X...

Страница 2: ...a en el producto avisa al usuario de la presencia de importantes instrucciones de uso y mantenimiento recogidas en la documentaci n proporcionada con el equipo Para obtener informaci n sobre directric...

Страница 3: ...PoleVault PowerCage PURE3 Quantum Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR TeamWork TouchLink V Lock VideoLounge VN Matrix VoiceLift WallVault WindoWall XTP XTP System...

Страница 4: ...er Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help In order to maintain compl...

Страница 5: ...Features and Operation 10 Bridged Mode Output 16 Troubleshooting 18 Amplifier Fails to Exit Standby Mode Promptly 18 Amplifier Enters Standby Mode Too Early 18 Limiter Protect LED Warning Indicators...

Страница 6: ......

Страница 7: ...outputs The XPA 2002 70V two channel amplifier delivers 200 watts rms per channel for 70 volt high impedance speaker systems The XPA 2002 100V two channel amplifier delivers 200 watts rms per channel...

Страница 8: ...channel Input 1 is output over the positive terminals of output channels 1 and 2 Input 3 is output over the positive terminals of output channels 3 and 4 The XPA 4002 has a toggle switch to input cha...

Страница 9: ...GREEN ACTIVE AMBER STANDBY DTP CROSSPOINT 4K SERIES DIGITAL PRESENTATION MATRIX 1 2 3 4 5 6 7 8 CONFIG VOLUME CONTROL MIC VOLUME I O OUTPUTS 1 2 3 4 5 6 7 8 9 10 INPUTS AUDIO VIDEO LOGO ENTER SELECT P...

Страница 10: ...SURROUND SOUND PROCESSOR 1 2 3 4 5 CLIP INPUTS MODE OVERRIDE TO ALL PL II IIx DOWNMIX DTS NEO 6 2 CH PCM D DTS SOURCE CONFIG VOLUME XPA 2004 LIMITER PROTECT SIGNAL 1 OVER TEMP 2 3 4 GREEN ACTIVE AMBE...

Страница 11: ...S OUTPUTS DMP 128 Plus 100 240V 1 5A 50 60 Hz STANDBY XPA 2004 GREEN ACTIVE AMBER STANDBY 1 G 2 2 1 4 3 3 4 LIMITE R PROTE CT SIGNA L 1 2 BRIDG E A 0 24 6 8 10 12 18 14 26 0 24 6 8 10 12 14 0 24 6 8 1...

Страница 12: ...io ground pins may be labeled as or The wiring and function are the same whichever way your product is labeled 5 mm MAX Tip Sleeve Ring Tip Sleeve Unbalanced Input Balanced Input 1 2 BRIDGE Figure 6 W...

Страница 13: ...g takes the signal from input 1 and outputs the 8 4 OUTPUTS CLASS 2 WIRING 1 2 BRIDGE 8 ONLY BRIDGE 8 Ohm combined output of 800 watts from the terminals of output channels 1 and 2 see the diagram at...

Страница 14: ...be powered up last The front panel LED of the amplifier should light green L amplificateur doit tre allum en dernier Le LED situ sur le panneau de l amplificateur devrait s allumer en vert 9 Adjust th...

Страница 15: ...low XPA 2002 LIMITER PROTECT SIGNAL 1 OVER TEMP 2 GREEN ACTIVE AMBER STANDBY XPA 2002 70V and XPA 2002 100V Front Panel A B C D XPA 2003C LIMITER PROTECT SIGNAL 1 OVER TEMP 2 3 GREEN ACTIVE AMBER STAN...

Страница 16: ...n the rear panel D Limiter Protect indicator LEDs channels 1 2 3 and 4 These LEDs representing output channels 1 2 3 and 4 light red in the following circumstances When audio clipping occurs the corre...

Страница 17: ...DE 8 4 OUTPUTS REMOTE 3 4 A B BRIDGE B CLASS 2 WIRING 1 2 3 4 ON OFF BRIDGE 8 ONLY BRIDGE A BRIDGE B XPA 2004 Rear Panel A B C E D F G H L K CLASS 2 WIRING 1 1 2 2 BRIDGE ON OFF 1 2 LIMITER PROTECT SI...

Страница 18: ...nnels 1 2 3 and 4 light red in the following circumstances When audio clipping occurs the corresponding LED turns on while the amplifier is limiting When the amplifier overheats both over temp and lim...

Страница 19: ...he XPA 2002 70V XPA 2002 100V and XPA 4002 70V have two switches one for each output channel The XPA 2003C 70V and XPA 2003C 100V have one switch for the line distribution output channel channel 3 Set...

Страница 20: ...speaker wires into the connector and tighten the captive screws Be sure to observe correct polarity Step 2 Insert the wired connector into the amplifier output and secure the locking screws on either...

Страница 21: ...rting on page 10 The output power of the XPA 4002 can be effectively doubled by using input channel 1 and bridging the outputs The output power of the XPA 2004 can be effectively doubled by using inpu...

Страница 22: ...Wiring On the input end only Input 1 is used in bridged mode 1 2 BRIDGE INPUTS XPA 4002 bridged mono output using parallel speaker wiring In bridged mode the output mode toggle switch for input 1 must...

Страница 23: ...t 3 are used in bridged mode XPA 2004 bridged mono output using parallel speaker wiring In bridged mode the output mode toggle switches for Input 1 A or Input 3 B or both must be set to the bridged Up...

Страница 24: ...urce until the signal LED lights consistently Amber Lit No output signal The amplifier has been placed in standby mode and output has been turned off Check the remoteport A DC fault may have been dete...

Страница 25: ...er to cool The LED is not lit after the amplifier recovers from the overheated state Output channel leads are shorted Check the speakers and speaker wiring for shorts Over Temp Indicator LED This indi...

Страница 26: ...rack environment may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron 2 Red...

Страница 27: ...Screws 100 24 0V 1 5 A 50 60 Hz STANDBY XP A 20 04 GR EE N AC TIV E AM BE R STA ND BY 1 G 2 2 1 4 3 3 4 LIMITER PR OT EC T SIGN AL 1 2 BRIDG E A 0 2 4 6 8 10 12 18 14 26 0 2 4 6 8 10 12 14 0 2 4 6 8...

Страница 28: ...E B CL AS S 2 WIR IN G 1 2 3 4 ON OF F BR IDG E 8 ON LY BR ID GE A BR ID GE B 10 0 2 40 V 1 5 A 50 60 Hz STANDBY XP A 20 04 GR EE N AC TIV E AM BE R ST AN DB Y 1 G 2 2 1 4 3 3 4 LIMITER PR OT EC T SI...

Страница 29: ...n South Africa South Tower 160 Jan Smuts Avenue Rosebank 2196 South Africa This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical a...

Отзывы: