XTP CrossPoint Series • Programming Guide
110
Command Function
SIS Command
(Host to Unit to Endpoint)
Response
(Endpoint to Unit to Host)
Additional Description
XTP SR HDMI, XTP SR HD 4K, and XTP SFR HD 4K scaler commands (continued)
Relay controls
Turn on an endpoint relay
EX@
*
X3(
*1RELY
}
Rely
X@
*
X3(
*1
]
Turn on relay
X3(
in output
X@
.
Turn off an endpoint relay
EX@
*
X3(
*0RELY
}
Rely
X@
*
X3(
*0
]
Turn off relay
X3(
in output
X@
.
Toggle an endpoint relay
EX@
*
X3(
*2RELY
}
Rely
X@
*
X3(
*
X4!]
Toggle (on-to-off or off-to-on) relay
X3(
in output
X@
.
Pulse an endpoint relay
EX@
*
X3(
*3*
X4)
RELY
}
Rely
X@
*
X3(
*3
]
Turn on relay
X3(
in output
X@
for an
interval defined as
X4)
. Each step of
X4)
is 16 ms.
Example:
E
1*2*3*45RELY
}
Rely1*2*3
]
Turn on relay 2 in output endpoint 1 for
720 ms
(0.72 sec,
X4)
= 45 * 16 ms = 720 ms).
View an endpoint relay status
EX@
*
X3(
RELY
}
X4!]
On or off.
View video and audio mutes
View output mutes
E
VM
}
X3*
1
X3*
2
...
X3*
n
]
Each
X3*
response is the mute status of
an output, starting from 1.
n
= is
16
or
32
.
Example :
(
XTP CrossPoint 3200
)
E
VM
}
Digital audio is muted on outputs 2 and
3, video on output 5, and video and
digital audio on output 26. All other
outputs are unmuted.
02201000000000000000000003000000
]
NOTE
:
X@
= Output number
01
–
16
or
32
X3*
= Video and audio mute status
0
= No mutes
4
= Analog audio mute
1
= Video mute
5
= Video and analog audio mute
2
= Digital audio mute
6
= Digital and analog audio mute
3
= Video and digital audio mute
7
= Video, digital audio, and analog audio mute
X3(
= Relay on endpoint
1
or
2
X4)
= Pulse duration
0
through
65535
(each step = 16 ms, see the example above)
X4!
= Relay status
0
= Off
1
= On
Содержание XTP CrossPoint 3200
Страница 6: ......
Страница 159: ...XTP CrossPoint Series Maintenance and Modifications 151 Figure 79 Button Label Blanks ...