XMP 240 C AT • Remote Control and Configuration
120
Command
ASCII command
(host to device)
Response
(device to host)
Additional description
Asynchronous Macro Responses
Macro started
McroSTARTED
X6(]
Macro finished
McroFINISHED
X6(]
Macro failed
McroFAILED
X6(
*
X7)]
Macro killed
McroKILLED
X6(
*
X7)]
KEY:
X6(
=
Macro number
1
through
64
. Response will be padded with a leading 0.
X7)
=
Macro status
0
= Macro idle
Dante Control and Configuration
The following commands configure the XMP 240 C AT to listen for and pass through SIS commands meant for
Extron AXI 02 AT, AXI 22 AT, and AXI 44 AT endpoints.
NOTE:
The XMP must be set to Verbose mode 2/3 when using the Dante Control and Configuration
commands.
Query available remote
devices
E
A
EXPR
}
X17&]X17&]
...
]]
Verbose 2/3:
ExprA
•X17&]
X7&]
...
]]
Enable remote
connection for listening
E
C
X17&
*
X22@
EXPR
}
ExprC
X17&
*
X22@]
All listening disabled
when XMP Dante module
rebooted
Read remote
connection listening
status
E
C
X17&
EXPR
}
X22@]
Verbose 2/3:
ExprC
X17&
*
X22@]
Query remote devices
being listened to
E
L
EXPR
}
X17&]X17&]
...
]]
Verbose 2/3:
ExprL
•X17&]
X17&]
...
]]
Send command to
remote device
{dante@
X17&
:
X19*
}
}
Verbose 2/3:
{dante@
X17&
}
X19(]
example command:
{dante@AXI02-XTP-
RoomA:wg40000*10AU|}|
example response:
{dante@AXI-XTP-RoomA}
DsG40000*10
]
KEY:
X17&
=
Dante Device Name
Device names are not case sensitive
X19*
=
SIS command
SIS command to be sent to remote dante-controlled device
X19(
=
SIS command response
Response from remote dante-controlled device, tagged by XMP
X22@
=
Extron Remote Connection
Mode
0
= Disabled
1
= Enabled