Reset Submenu
The
Reset
submenu allows you to reset many parameters to the factory defaults. It also
allows you to run the Sanitize process.
Reset
MENU
NEXT
Reset [Factory IP]
[Activate]
NEXT
NEXT
Are you sure?
[Yes]
System Reset
in progress
Figure 82.
VNE 250 Encoder Reset Submenu
1.
In the main
Reset
screen, press
Next
to open the
Reset
options screen.
2.
In the
Reset
options screen, use the left rotary encoder to select which type of reset
you want. You can choose
Factory
IP
or
Sanitize
:
Factory
IP
— restores the following parameters to the factory default:
•
IP address
•
Subnet mask
•
Gateway IP address
•
Controller IP address
•
Link speed set to auto
•
Static IP address
•
Controller port number
For factory default values see
Sanitize
— runs the sanitize process to overwrite volatile scaler memory (for the
on-screen display), volatile wavelet memory, and all non-volatile memory. All these
memory locations are overwritten three times:
•
Firstly with a random pattern of zeroes and ones.
•
Secondly with binary zeroes.
•
Thirdly with binary ones.
3.
Use the right rotary encoder to toggle between
Activate
or
Cancel
.
4.
Press
Next
.
5.
If you selected
Activate
in step 3, you are prompted about whether you want to
proceed. Press
Yes
.
6.
Press
Next
.
7.
If you selected
Activate
in step 3, one of the reset processes runs. The screen shows
System
Reset
in
Progress
.
8.
When the reset is complete, press
Next
to return to
page 94).
VNM 250 • Front Panel Menu Configuration