Setup Guide — P/2 DA4xi and P/2 DA6xi
Installation
The Extron P/2 DA4xi and P/2 DA6xi are
distribution amplifiers taking one video input
(VGA to QXGA) and distributing it to one
buffered loop-through and three (P/2 DA4xi) or
five (P/2 DA6xi) individually buffered outputs.
To install and operate either unit, follow the steps
below.
Step 1
Ensure all devices are powered off or electrical cables are disconnected.
Step 2
Choose a suitable location and mount the distribution amplifier on a table, in a
rack, or under a desk.
Step 3
Connect a computer source to the 15-pin HD female input connector of the
distribution amplifier.
Step 4
Connect four (P/2 DA4xi) or six (P/2 DA6xi) high-resolution display devices to
the 15-pin HD output connectors of the distribution amplifier.
N
Output 1, which is labeled “Local Monitor” is used for DDC reference.
Step 5
Power on the distribution amplifier.
Step 6
Power on the displays.
Step 7
Power on the source.
Troubleshooting
If the video output is “soft” on any display,
move the video gain switch on the
rear panel to the up (1V) position.
If no image appears:
Check all the input and output video cables are connected and secure.
•
Check all devices are receiving power.
•
If the issue still persists, call the Extron support hotline.
•
Extron
USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517
FAX
Extron
USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797
FAX
Extron
Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050
FAX
Extron
Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664
FAX
Extron
Japan
+81.3.3511.7655
+81.3.3511.7656
FAX
Extron
China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566
FAX
Extron
Middle East
+971.4.2991800
+971.4.2991880
FAX
68-991-50
A
02 09