TeamWork 400 Kit • Installation Guide (Continued)

4

Installation

Install the Cable Pass-through Cassette Module and Show Me Cables

Detailed instructions are in the 

Cable Cubby Setup Guide

.

Extron recommends the layout shown to the right with cable 
pass-through module to the left of the power module.

NOTE:

  The figure to the right shows the US power 

module. Power modules for other countries look 
different.

INPUT

(to source device)

Top of Cable Cubby

OUTPUT 

(to switcher)

Bottom of

Cable Cubby

Share Button

Three-conductor 

pigtail for contact 

closure and tally

ATTENTION:

• 

The end with the button and LED connects to the input 
devices and must come out of the top of the Cable 
Cubby.

• 

Le bout avec le bouton et la LED se connecte 
aux appareils d’entrée et doit ressortir du haut du 
Cable Cubby.

• 

The end with the three-conductor pigtail connects to 
the switcher and must come out of the bottom of the 
Cable Cubby.

• 

Le bout avec le mini câble à trois conducteurs se 
connecte au sélecteur et doit ressortir du bas du 
Cable Cubby.

1. 

Assemble the cable pass-through cassette module as 
shown in the diagram to the right.

2. 

Insert the cable cassette module into the Cable Cubby from 
underneath and secure them in position with the provided 
#4-40 Phillips head screws and star washers.

Install the Power Modules in the Cable Cubby

Insert the power module into the Cable Cubby from underneath 
and secure the power modules in position with the provided 
#4-40 Phillips head screws and star washers.

 WARNING:

 

Possible electric shock:

 To ensure 

good electric grounding, you must use the star 
washers with the screws.

AVERTISSEMENT:

 

Risque de choc électrique:

 

Afin d’assurer une mise à la terre correcte, vous 
devez fixer les modules d’alimentation au Cable 
Cubby à l’aide de vis et de rondelles en étoile.

Power Module

Cable Pass-through Cassette Module

125V~ 1

2A MAX 

TO

TAL

Secure the modules

using two of the

provided screws.

Slide the cassette modules 

into the Cable Cubby from

underneath.

1

1

2

2

Insert Show Me 

Cables into the 

grommet plate.

1

Attach the Trim Plate

to the top of the module,

using the included

screws.

2

Attach the grommet 

plate to the bottom 

of the module, using 

the included screws.

3

Содержание TeamWork 400

Страница 1: ...DIG ITA L I O PW R OU T 6W eB US V S S G S G LA N IPC P PR O PC S1 100 24 0V 10A MA X 50 60H z INP UT 100 24 0V 10A MA X 50 60H z Contact Closure Tally Extron SW4 HD 4K 4K HDMI Switcher The diagram a...

Страница 2: ...ment Works with most commercially available flat panel displays laptops and tablets HDCP compliant Section 508 compliant Kit Components When your kit is delivered check that all the components are pre...

Страница 3: ...rade displays do not have integrated speakers and do not support audio playback Typically source devices with HDMI output connectors embed audio onto the HDMI connector NOTES Always check and test com...

Страница 4: ...ssortir du bas du Cable Cubby 1 Assemble the cable pass through cassette module as shown in the diagram to the right 2 Insert the cable cassette module into the Cable Cubby from underneath and secure...

Страница 5: ...ubby Cable Access Enclosure HDMI Show Me Cable System Controller Switcher Power Supplies 2 AC Power To Display SW4 HD 4K PLUS HDMI SWITCHER 1 R CONFIG SIGNAL INPUTS INPUTS OUTPUT 1 2 HDCP 4 AUTO SWITC...

Страница 6: ...ntrol Processor RS 232 Control Cable Flat Panel AC Cord Adapter Extron HDMI Pro Cable HDMI Video Flat Panel Display w Integrated Speakers Extron Show Me Cables CA BL E CU BB Y Regional Sales 0 30 60 9...

Страница 7: ...G G C T G C G 1 2 3 4 C T T G C T V RS 232 AUTO CONTACT IN TALLY OUT 2 3 4 INPUTS OUTPUT REMOTE 3 Connect the black Tally Out and red Contact pigtail wires as shown above The number next to the Tally...

Страница 8: ...ort on the switcher with the provided control cable Switcher SW4 HD 4K Tx Rx G RS 232 AUTO 3 pole connector to switcher 3 pole connector to system controller Switcher Control Cable System Controller I...

Страница 9: ...he switcher When the button on the second Show Me cable is pressed the LED lights blue and the LED on the first cable is switched off 10 Disconnect all the Show Me cables from the source devices After...

Страница 10: ...ron com company contactus aspx Cause 5 Problem with Switcher Solution If none of the cables work correctly there may be a problem with the switcher Contact an Extron Support representative at www extr...

Отзывы: