StudioStation 100 • Web-Based User Interface
45
HDMI Output Configuration
Figure 29.
HDMI Output Configuration Panel
The refresh rate for the output of the StudioStation 100 can be selected from the drop-down
list. Choose
50
Hz or
60
Hz. The
Resolution
of the HDMI output can be viewed in this
panel. It is configured in the
NOTE:
The resolution of the local (preview) output follows (is based on) the recording
encoder resolution.
Outputting and using a video test pattern
NOTE:
No input signal is needed when using a test pattern for display device setup.
The
OSD
Configuration
panel in the
Input/Output
Settings
page allows selection and
immediate output of one of eight internally stored test patterns to the HDMI output from
the StudioStation 100 as well as to the recording and output stream. Video test patterns
are helpful for calibrating connected displays or projectors for color, convergence, focus,
resolution, contrast, and aspect ratio. The audio test option is used for testing audio output.
To select and output a test pattern:
1.
Open the
Input/Output
Settings
page.
2.
Expand the
OSD
Configuration
panel.
3.
Select a pattern from the
Test
Patterns
drop-down list. A preview of the test pattern
appears above the drop-down list. Available test patterns include the following:
Color Bars
Time Stamp
Pulse
Crop
Aspect Ratio 1.33:1
Aspect Ratio 1.78:1
Aspect Ratio 1.85:1
Universal OSD
Figure 30.
Test Patterns
•
Select
Pulse
to output an audio pulse of 400 Hz at -10 dBu for audio output
testing.
•
The
Universal
OSD
pattern can be displayed together with the main AV content
because it overlays the video rather than replacing it. As a result, the universal OSD
pattern can be used at any time (see
on the next
page).
The selected test pattern is immediately output to the display and reflected in the preview
in the
AV
Controls
panel. The test pattern displays until another pattern, or
Off
is selected
from the
Test
Pattern
drop-down list, or until unit power is recycled.
NOTE:
When a test pattern is selected, it is streamed to the display, stream, and
recording, overlaid atop the source AV material. If
Off
is selected from the
Test
Pattern
drop-down list, the test pattern is turned off.
figure 29