![Extron electronics SMP 111 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/extron-electronics/smp-111/smp-111_user-manual_2457360080.webp)
SMP 111 • Remote Communication and Control
72
Command and Response Tables (continued)
Command
Function
SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
Resets
Reboot system
E
1BOOT
}
Boot1
]
Complete system reboot.
Restart the network
E
2BOOT
}
Boot2
]
Reset flash
E
ZFFF
}
Zpf
]
Reset flash memory
(excludes recording files).
System Reset (factory
defaults)
E
ZXXX
}
Zpx
]
Resets device to default and
deletes recorded files.
Reset all device
settings and delete
recording files
E
ZY
}
Zpy
]
Reset to default except IP
address, delete all user and
recorded files.
NOTE:
This reset excludes IP settings such as IP address, subnet mask, gateway IP address, unit name, DHCP setting and port mapping
(Telnet/Web/direct access) in order to preserve communication with the device.
Absolute reset
E
ZQQQ
}
Zpq
]
Same as
System
Reset
, plus
resets the IP address and subnet
mask to defaults.
File
Commands
Change directory
E
path/directory/
CJ
}
Dirl
path/directory/
]
Return to root
directory
E
/
CJ
}
Dirl/
]
Up one directory
E
..
CJ
}
Dirl
path/directory/
]
View current directory
E
CJ
}
path/directory/
]
Erase current
directory and
included files
E
/EF
}
Ddl
]
Also deletes files inside
directory.
Erase current
directory and sub‑
directories
E
//
EF
}
Ddl
]
List files from current
directory and below
E
LF
}
path/filename
•
date/time
•
length
]
path/filename
•
date/time
•
length
]
path/filename
•
date/time
•
length
]
...
space_remaining
•
Bytes Left
]]
filename/date/time/bytes left