Quantum Ultra Series Videowall Processing Systems • Installation and Configuration
20
Card Locations — Quantum Ultra and Ultra II 610 and 305
When the Quantum Ultra Series processor is assembled at the factory, the cards are
installed according to the following rules:
•
All the input cards are installed in slots
above
all the output cards in the chassis.
•
Each card slot can contain either an input or an output card, depending on the
configuration that was ordered (at least one input and one output card must be
installed). However, because all the input cards must be installed together
above
the
output cards in the chassis, slot 1 never contains an output card and slot 10 (610
models) or slot 5 (305 models) never contains an input card.
•
All input cards of the same type (HDMI, HDMI 4K PLUS, IN SMD 100, or
Expansion In) are installed together, as are all output cards of the same type (HDMI,
HDMI 4K PLUS, DTP, or Expansion Out).
If installing cards yourself
Do not intersperse:
•
Input cards with output cards
•
Input cards of different types
— HDMI input cards, HDMI 4K PLUS input cards,
and IN SMD 100 cards with each other, or
•
Output cards of different types
— HDMI output cards, HDMI 4K PLUS output
cards, and DTP cards
Install the cards in the chassis in the following order, top to bottom:
1.
Expansion IN
(not available on Quantum Ultra II)
2.
IN SMD 100
3.
IN4HDMI
4.
IN4HDMI 4K PLUS
(available on Quantum Ultra II models only)
5.
OUT4HDMI
6.
OUT4DTP
7.
OUT4HDMI 4K PLUS
(available on Quantum Ultra II models only)
8.
Expansion OUT
(not available on Quantum Ultra II)
NOTES:
•
Do not
leave empty slots between cards (input or output) in the chassis. This
prevents the unit from functioning. Card slots that remain empty must be at the
bottom of the card slots section.
•
The expansion output and input cards have special rules for placement in card
slots (see
on page 47 for more information on the
location of these cards).