PS 1230 External Power Supply • 

 

Installation Guide

About the PS 1230 Power Supply

Model

Part 

Number

Power Output

Termination

PS 1230

70-769-01

36 watts, 12 VDC,  

8 A peak, 3 A continuous; shared 

between all three outputs

Captive screw

ZipClip

 200 101-001-01

Connector Wiring

Ridged

Smooth

Tie

Wrap

3/16"

(5 mm) Max.

Captive Screw

Connector

Power Supply

Output Cord

         

Sleeve (-)

Tip (+)

Captive Screw Connector

Captive Screw Connector

Captive Screw Connector

DC Power Plug

Smooth

Ridged

Features

Power

LED

ZipClip 

Mounting Slot

(front and rear)

Notches for 

Securing

Tie Wrap

AC

Power

Input

DC Power

Outputs

Using the ZipClip 200

Attaching and Removing the Clip and Power Supply

To 

attach

 the power supply to the ZipClip 200 mounting clip: 

1. 

Insert the bottom of the power supply down into the clip, starting with one 
end.

2. 

Pivot the other end down and press until the clip snaps into place.

To 

remove

 the power supply from the ZipClip:

1. 

Press the tab on the ZipClip.

2. 

Pivot the power supply and lift it out of 
the ZipClip.

b

a

Rack Mounting

Mounting to a Rack Shelf

These power supplies are one quarter rack wide. Up to four power supplies can 
be mounted side by side directly onto a rack shelf.

1. 

Align the threaded holes in the bottom of the power supply with the holes in 
an Extron rack shelf and fasten the supply to the shelf with two screws as 
shown below.

b

a

(2) 4-40 x 3/16"

Screws

RSB 123

Rack Shelf

Rack Mounted

2. 

Bolt the rack shelf to the rack.

Contents

About the PS 1230 Power Supply ..................... 1

Connector Wiring........................................... 1
Features ......................................................... 1

Using the ZipClip 200 ........................................ 1

Attaching and Removing the Clip and Power 

Supply .......................................................... 1

Using Tie Wraps for Cable Strain Relief ........ 1

Rack Mounting .................................................. 1

Mounting to a Rack Shelf .............................. 1
Mounting to Rack Rails Using a ZipClip ........ 1

Furniture Mounting ............................................ 2
Pole Mounting ................................................... 2
Specifications .................................................... 2
Safety Instructions............................................. 2

Using Tie Wraps for Cable Strain Relief

1. 

Attach the power supply to the ZipClip 200 mounting clip as described 
previously.

2. 

Fasten the power output cords to the ZipClip base.

a. 

Insert tie wraps (which are also called “zip ties”) along the notches 
on the side of the power supply and through the tie wrap anchor 
points on the ZipClip, then around the cord.

b. 

Connect and pull the tie wraps until they are secure. Do not over 
tighten.

Tie Wrap

Mounting to Rack Rails Using a ZipClip

1. 

Fasten the ZipClip 200 mounting clip to a rack rail using two rack screws 
(see the diagram below).

2. 

Insert the bottom of the power supply down into the clip, starting with one 
end.

3. 

Pivot the other end toward the clip and press until the clip snaps into place.

Inside of Rack

ZipClip 200

Back of Rack

Side of Rack

Important Safety Instructions

This symbol is intended to alert the user of 
important operating and maintenance (servicing) 
instructions in the literature provided with the 
equipment.

This symbol is intended to alert the user of the 

presence of uninsulated dangerous voltage within 

the product enclosure that may present a risk of 

electric shock. On the product, risk of shock may 
be indicated by this symbol.

Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the 
other. A grounding type plug has two blades and a third grounding 
prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly at 

plugs, convenience receptacles, and the point where they exit from 
the apparatus.

Only use attachments/accessories specified by the manufacturer.
Unplug this device apparatus during lightning storms or when unused 

for long periods of time.

WARNING:

  To reduce the risk of fire or electric shock, do not 

expose this apparatus to rain or moisture.” 
“This apparatus shall not be exposed to dripping or splashing 
and no objects filled with liquids, such as vases shall be placed 
on the apparatus”

Refer all servicing to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as when 
the power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has 
been dropped.

WARNING:

  This apparatus is a Class I product. This product 

must be connected to a MAINS socket outlet with a protective 
earthing connection.

The mains plug is used as the disconnect device and shall remain readily 

operable.

To prevent the risk of shock, do not attempt to service this equipment 

yourself because opening or removing covers may expose you to 
dangerous voltage or other hazards.

WARNING:

 

Power sources

 • This equipment should be operated only from 

the power source indicated on the product. This equipment 
is intended to be used with a main power system with a 
grounded (neutral) conductor.  The third (grounding) pin is a 
safety feature, do not attempt to bypass or disable it.

Power disconnection

 • To remove power from the equipment 

safely, remove all power cords from the rear of the equipment, 
or the desktop power module (if detachable), or from the 
power source receptacle (wall plug).

See the next page for furniture mounting instructions.

NOTES REGARDING REVISION C:

 

z

Added altitude and sea level text and 
symbols for CCC compliance per Homi.

 

z

Added standard Extron logo document 
header.

 

z

Updated corporate contact info to include 
India and Korea offices and updated 
phone numbers throughout.

 

z

Updated 5 illustrations

 

z

Replaced specifications with latest 
version.

 

z

Changed various fonts and styles to 
current department style.

 

z

See this ER: 
http://intranet/app/ER/ERGeneration/
logdetail.aspx?logid=11838 .

Base level part number: 
28-113-07LF.

Отзывы: